Fluke 3000 FC Series Wireless Multimeter
Compare products: digital multimeters
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 87V TRMS Industrial Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 179 TRMS Digital Multimeter with temperature readings
- Fluke 117 Electricians Multimeter with Non-Contact voltage
- Fluke 115 Digital Multimeter for Technicians
- Fluke 177 True-RMS Digital Multimeter with display backlight
- Fluke 289 TRMS Industrial Logging Multimeter with TrendCapture
- Fluke 28 II TRMS Rugged IP67 Digital Multimeter
- Fluke 116 HVAC Multimeter with Temperature and Microamps
- Fluke 287 True-RMS Electronics Logging Multimeter
- Fluke 114 Electrical Multimeter
- Fluke 113 Digital Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke 77 IV Digital Multimeter
- Fluke v3000 FC Wireless AC Voltage Module
- Fluke v3001 FC Wireless DC Voltage Module
- Fluke 107 Pocket Digital Multimeter
- Fluke 1587 FC Insulation Multimeter
Key Features
- Full featured multimeter that also reads results wirelessly from remote Fluke Connect® wireless modules
- Measures AC and DC voltage to 1000 V, AC and DC current, and temperature
- Shows up to four readings simultaneously on a bright white backlit display
- Sends measurement data to your smartphone
- Safety rated CAT III 1000 V, Cat IV 600 V; IP54
Product overview: Fluke 3000 FC Series Wireless Multimeter
The Fluke 3000 FC with Fluke Connect provides all the facts right in the field.
With its precision, reliability, and ease of use, the Fluke 3000 FC Wireless Multimeter has all the essential electrical and electronic troubleshooting features professional technicians need. It gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging, plus a frequency, capacitance, resistance, continuity and diode measurements.
Reduces arc flash risk
Independently tested for safe use in CAT IV 600V/CAT III 1000 V environments, the Fluke 3000 FC DMM and Fluke Connect wireless modules put tools, not your body, near live electrical panels. Just de-energize the cabinet; open the panel while wearing PPE; and connect the remote modules—voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC from a safe distance up to away. You can view the meter measurement, plus readings from up to three wireless modules all on the same screen. And by separating yourself from hazardous measurement situations you’ll reduce the risk of arc flash.
Gives the full picture in real time.
With Fluke Connect-enabled tools you can connect multiple remote modules in different parts of the system and view the interaction between remote test points on a single screen, in real time. Create and email reports right from the field, or download the data to a PC for further analysis. The Fluke 3000 FC connects to your smartphone through Bluetooth so you can send measurement data from the meter to your phone and share it with your team anytime, from anywhere.
Other useful capabilities:
- Record measurements over time and monitor changes live on your phone.
- Share the results using Fluke Cloud™ storage and ShareLive™ video call.
- Provides True-RMS voltage and current measurements with 6000-count resolution
- Share results with remote team members instantly with ShareLive™ video call
- Includes continuity, resistance, diode test, capacitance, and frequency tests, plus MIN/MAX recording
- Provides 0 09% basic accuracy
- Works with a standard amp clamp or with a flexible iFlex clamp
- Shows meter measurement and readings from up to three modules simultaneously
- Allows mixing and matching modules to meet your specific measurement needs
- Current, voltage and temperature modules are available separately or in Fluke Connect kits
- Runs on three AA Alkaline batteries, providing 250 hours minimum battery life
- Comes with three-year standard warranty
What's in the box:
- Fluke 3000 FC True-RMS Wireless Multimeter
- (1 pair) TL175 Test Leads
- (1 pair) AC175 Alligator Clips
- Quick reference guide
Specifications: Fluke 3000 FC Series Wireless Multimeter
AC Voltage | ||
Range¹ / resolution | 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V | |
Accuracy2 3 4 | 45 Hz to 500 Hz | 1.0% + 3 |
500 Hz to 1 kHz | 2.0% + 3 | |
1. AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. | ||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||
mV | Range / resolution | 600.0 mV / 0.1 mV |
Accuracy | 0.09% + 2 | |
V | Range / resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V |
Accuracy | 0.09% + 2 0.15% + 2 | |
))) | Range / resolution | 600 Ω / 1 Ω |
Accuracy | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
Ω | Range / resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ |
Accuracy | 0.5% + 2 0.5% + 1 1.5% + 3 | |
Diode test | Range / resolution | 2.000 V / 0.001 V |
Accuracy | 1% + 2 | |
µF | Range / resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF |
Accuracy | 1.2% + 2 10% typical | |
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2. | ||
AC and DC Current | ||
mA AC (45 Hz to 1 kHz) | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA |
Accuracy | 1.5% + 3 | |
mA DC2 | Range1 / resolution | 60.00 mA / 0.01 mA 400.0 mA3 / 0.1 mA |
Accuracy | 0.5% + 3 | |
1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. | ||
Frequency | ||
Range / resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz | |
Accuracy1 | 0.1% + 1 | |
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | ||
Input Characteristics | ||
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio (1 kΩ unbalance) | > 60 dB, DC to 60 Hz | |
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | > 10 MΩ < 100 pF | |
Common mode rejection ratio (1 kΩ unbalance) | > 120 dB at DC, 50 Hz or 60 Hz | |
Normal mode rejection | > 60 dB at 50 Hz or 60 Hz | |
Open Circuit Test Voltage | ||
Overload protection | 1100 V RMS | |
Input impedance (nominal) | < 2.7 V DC | |
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | < 0.7 V DC < 0.9 V DC | |
Typical short circuit current | < 350 mA | |
Overload protection | 1100 V RMS | |
Input impedance (nominal) | < 2.7 V DC | |
Full scale voltage to 6 MΩ Full scale voltage 50 MΩ | 2.000 V DC | |
Typical short circuit current | < 1.1 mA | |
mA Function | ||
Overload protection | Fused, 44/100 A, 1000 V FAST Fuse | |
Overload | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | |
MIN/MAX Recording Accuracy | ||
DC functions | ± 12 counts for changes > 350 mS in duration. | |
AC functions | ± 40 counts for changes > 900 mS in duration. | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | |
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |
Display (LCD) | Update rate | 4/sec |
Volts, amps, ohms | 6000 counts | |
Frequency | 10,000 counts | |
Capacitance | 1,000 counts | |
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | |
Battery life | 250 hours minimum | |
RF communications | 2.4 GHZ ISM Band | |
RF communication range | Open air, unobstructed | Up to 20m |
Obstructed, sheetrock wall | Up to 6.5m | |
Obstructed, concrete wall, or steel electrical enclosure | Up to 3.5m | |
Temperature | Operating | -10°C to 50°C |
Storage | -40°C to 60°C | |
Temperature coefficient | 0.1 X (specified accuracy) / °C (< 18°C or > 28°C) | |
Relative humidity | 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) | |
Altitude | Operating | 2,000 m |
Storage | 12,000 m | |
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326–1:2006, EN 61326–2–2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008 FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE | |
Safety compliance | ANSI / ISA 61010–1 / (82.02.01): 3rd edition CAN / CSA-C22.2 No 61010-1-12: 3rd edition UL 61010–1: 3rd edition IEC / EN 61010–1:2010 | |
Certifications | CSA, FCC, CE | |
Ingress Protection (IP) rating | IP54 | |
Pollution Degree | 2 | |
Size (H x W x L) | 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) | |
Weight | 340 g (12 oz) | |
Warranty | Three years | |
Not compatible with Fluke CNX test tools |
Models: Fluke 3000 FC Series Wireless Multimeter
Includes:
- True-RMS Wireless Multimeter
- TL175 Test Leads
- AC175 Alligator Clips
Manuals + Resources: Fluke 3000 FC Series Wireless Multimeter
- 3000 FC | Users manual
- 3000 FC | Calibration manual
- 3000 FC | Calibration manual supplement
- 3000 FC | Statement of memory volatility
- 3000 FC | Quick reference guide
- 3000 FC | Safety sheet
- a3000 FC | Quick reference guide
- a3000 FC | Safety sheet
- a3000 FC | Calibration manual
- a3001 FC | Quick reference guide
- a3001 FC | Calibration manual
- a3001 FC | Safety sheet
- a3001 FC | Safety sheet supplement
- a3002 FC | Quick reference guide
- a3002 FC | Calibration manual
- a3002 FC | Safety sheet
- Fluke Connect | Quick reference guide
- Fluke Connect Wi-Fi to Thermal Imager | Quick reference guide
- ir3000 FC | Quick reference guide
- pc 3000 FC | Instruction sheet
- Radio Frequency Data Class B | Instruction sheet
- t3000 FC | Calibration manual
- t3000 FC | Quick reference guide
- t3000 FC | Safety sheet
- t3000 FC | Safety sheet supplement
- v3000 FC | Calibration manual
- v3000 FC v3001 FC | Quick reference guide
- v3000 FC v3001 FC | Safety sheet
- v3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC | Statement of memory volatility
- v3001 FC | Calibration manual