Fluke 1662 Multifunction Tester with TruTest Data Management Software Kit

Model#: Fluke 1662 FTT Kit
  • Fluke 1662 FTT Kit 01

Key features

  • 1662 Multifunction Tester
  • TruTest Data Management Software"

Product overview: Fluke 1662 Multifunction Tester with TruTest Data Management Software Kit

Fluke 1662 Multifunction Tester

The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.

Fluke TruTest Data Management Software

Fluke TruTest Software is designed to eliminate the hassle associated with traditional electrical system data management and reporting. Whether you are testing fixed wire installations, or appliances in an office, verifying repairs in a workshop, or performing annual inspections proper data management is critical for producing easy-to-understand reports for clients. Compatible with a growing list of Fluke and Beha-Amprobe test and measurement devices TruTest Software allows you to quickly and easily import measurement results directly from your test instruments, manage files transferred from instruments, or manually enter data as needed.

What's in the box:

  • 1662 Multifunction Installation Tester
  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • IR189USB cable
  • TruTest Data Management Software

Specifications: Fluke 1662 Multifunction Tester with TruTest Data Management Software Kit

AC voltage measurement
Range500 V
Resolution0.1 V
Accuracy 45 Hz – 66 Hz0.8% + 3
Input impedance360 kΩ
Overload protection660 V rms
Continuity testing (RLO)
Range (autoranging)20 Ω / 200 Ω / 2000 Ω
Resolution0.01 Ω / 0.1 Ω / 1 Ω
Open Circuit Voltage>4 V
Insulation resistance measurement (RISO)
Accuracy of tTest voltage (at rated test current)+10%, -0%
Test voltage100 V
250 V
500 V
1000 V
Insulation resistance range20 MΩ / 50 MΩ
20 MΩ / 100 MΩ
20 MΩ / 200 MΩ
20 MΩ / 200 MΩ / 500 MΩ
20 MΩ / 200 MΩ / 1000 MΩ
Resolution0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
0.01 MΩ / 0.1 MΩ / 1 MΩ
Test current1 mA @ 50 kΩ
1 mA @ 100 kΩ
1 mA @ 250 kΩ
1 mA @ 500 kΩ
1 mA @ 1 MΩ
Loop and line impedance (ZI)
Range10 Ω / 0.001 Ω / High current mΩ mode
Resolution0.01 Ω / 0.1 Ω / 1 Ω
Prospective earth fault current, PSC test
Range1000 A / 10 kA (50 kA)
Resolution1 A / 0.1 kA
ComputationProspective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
RCD testing, RCD types tested
RCD TypeA4, AC¹, G², S³
Notes¹Responds to AC
²General, no delay
³Time delay
4Responds to pulsed signal
5Responds to smooth DC signal
Tripping speed test (ΔT)
Current settings¹10-30-100-300-500-1000 mA – VAR
10-30-100 mA
Multiplierx ½, x 1
x 5
Measurement rangeRCD Type G310 ms
50 ms
RCD Type S510 ms
160 ms
Notes¹1000 mA type AC only
700 mA maximum type A in VAR mode
VAR mode not available for type B.
RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
Current range30% to 110% of RCD rated current¹
Step size10% of IΔN²
Dwell timeType G300 ms/step
Type S500 ms/step
Measurement accuracy±5%
Specified trip current ranges (EN 61008-1)50% to 100% for Type AC
35% to 140% for Type A (>10 mA)
35% to 200% for Type A (≤10 mA)
50% to 200% for Type B
²5% for Type B
Notes¹30% to 150% for Type A IΔN > 10 mA
30% to 210% for Type A IΔN = 10 mA
20% to 210% for Type B
Phase Sequence Indication
Iconicon phase sequence indicator

 Phase Sequence indicator is active.

General Specifications
Size (L x W x H)10 x 25 x 12.5 cm
Weight (incl. batteries)1.3 Kg
Battery size, quantityType AA, 6 ea.
SealingIP-40
SafetyComplies with EN/IEC 61010-1 and EN/IEC 61010-2-034
OvervoltageCAT III / 500V; CAT IV 300V
PerformanceEN61557-1 to EN61557-7 and EN61557-10
FunctionDemoLiteAdvanced
Database structure (Local standalone or server based)LocalLocalLocal
 
Portable Appliance Tester (PAT) module•••
Portable Appliance Testers supportedFluke 6500, Fluke 6500-2, Beha-Amprobe GT-600, Beha-Amprobe GT-650, Beha-Amprobe GT-800, Beha-Amprobe GT-900
Maximum addable clients12Unlimited
Maximum addable sites/client25Unlimited
Maximum addable locations/client550Unlimited
Maximum addable appliances/client201000Unlimited
 
Installation Testers (INST) module•••
Installation Testers supportedFluke 1653, Fluke 1653B, Fluke 1654B, Fluke 1662, Fluke 1663, Fluke 1664 FC, Beha-Amprobe ProInstall-100, Beha-Amprobe ProInstall-200
Maximum addable clients12Unlimited
Maximum addable sites/client25Unlimited
Maximum addable locations/client525Unlimited
Maximum addable appliances/client50200Unlimited
 
Include demo database•••
Create clients•••
Rename clients ••
Delete clients•••
 
Create nodes•••
Move nodes•••
Rename nodes ••
Delete nodes•••
 
Edit client information ••
Edit site information ••
Edit location information ••
Edit appliance information ••
Edit test information ••
 
Add test step ••
Delete test step ••
Edit test step ••
 
Add remarks ••
Add attachment (file) to remark  •
Edit remark ••
Delete remark ••
 
Read data from instrument•••
Read data from file•••
Read data conflict management•••
Read data assign tree structure•••
Load data to instrument  *Compatible tool required
 
Use search•••
 
Show reportsWith watermark••
Show certificatesWith watermark••
Save (PDF, XML,…) /Print reports ••
Save (PDF, XML,…)/Print certificates ••
 
Add engineersDemo engineer••
Edit engineers ••
Delete engineers ••
Print engineers ••
Add test instrumentsDemo instrument••
Edit test instruments ••
Delete test instruments ••
Print test instruments ••
 
Edit my company infoDemo company••
Edit company logoDemo logo •
Edit certification logoDemo logo •
 
View Auto Test Codes•••
Select favorites Auto Test Codes ••
Print favorites Auto Test Codes ••
Print All Auto Test Codes ••
Create customized Auto Test Codes  •
Edit customized Auto Test Codes  •
Copy customized Auto Test Codes  •
Delete customized Auto Test Codes  •
Print Customized Auto Test Codes  •
 
Create backup ••
Restore backup ••
 
Maximum users1 Demo user2Unlimited
Add users ••
Edit users ••
User roles ••
Edit user roles ••
Print users list ••
 
Edit limits ••
Available languagesEN, DE, FR, IT, NL
Supported Installation certificatesDIN VDE 0701-0702, ÖVE/ÖNORM E 8701, SNR 462638, NEN3140, International template
Change language•••
Change country•••
Change report language  •
 
Expire duration60 days (calculated from installation date)Unlimited
Free updates5 years (calculated from enter serial code date)
Expiration popup noticeDailyEvery 30 days after 5 year free update period
Activation date with days left until expiration•••

System requirements

TypeRequirement
Operating System
  • Microsoft Windows 10, 64-bit and 32-bit (recommended)
  • Microsoft Windows 8/8.1, 64-bit and 32-bit
  • Microsoft Windows 7 with Service Pack 1, 64-bit and 32-bit
System MemoryMinimum 4 GB RAM (64-bit) or 2 GB RAM (32-bit)
Hard disk spaceMinimum 2 GB available hard disk space
Display resolutionMinimum screen resolution 1366 x 768
Communication interfacesUSB

Models: Fluke 1662 Multifunction Tester with TruTest Data Management Software Kit

Fluke 1662 FTT Kit

Fluke 1662 Multifunction Tester with TruTest Software Kit


Buy it

Includes:

  • 1662 Multifunction Installation Tester
  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • IR189USB cable
  • TruTest Data Management Software
Fluke 1662 SCH FTT Kit

Fluke 1662 Multifunction Tester with TruTest Software Kit


Buy it

Includes:

  • 1662 Multifunction Installation Tester
  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • IR189USB cable
  • TruTest Data Management Software
Fluke 1662 ITDK FTT Kit

Fluke 1662 Multifunction Tester with TruTest Software Kit


Buy it

Includes:

  • 1662 Multifunction Installation Tester
  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • IR189USB cable
  • TruTest Data Management Software
Fluke 1662 CH FTT Kit

Fluke 1662 Multifunction Tester with TruTest Software Kit


Buy it

Includes:

  • 1662 Multifunction Installation Tester
  • 6x AA (IEC LR6) cell batteries
  • C1600 hard carrying case
  • Zero adapter
  • Heavy duty mains cord
  • STD standard test lead set
  • Padded carrying and waist strap
  • Quick reference guide
  • TP165X remote control probe and lead
  • IR189USB cable
  • TruTest Data Management Software

Manuals + resources: Fluke 1662 Multifunction Tester with TruTest Data Management Software Kit

Chat with ourFluke assistant
Clear Chat