Fluke 87V TRMS Industrial Multimeter

Fluke 87V Industrial Multimeter is rated 4.7 out of 5 by 161.
  • y_2024, m_10, d_24, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_31, tr_130
  • loc_en_US, sid_3739292368948, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 46.24ms
  • REVIEWS, PRODUCT
  • Fluke 87V Industrial Multimeter
  • Fluke 87V Industrial Multimeter
  • Fluke 87V Industrial Multimeter
  • Fluke 87V Industrial Multimeter

Key features

The Fluke 87V industrial digital multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment.

  • Safer and rugged: Safety rated CAT III 1000 V, CAT IV 600 V
  • Accurate: Measure current, voltage and frequency on complex variable frequency drive (VFD) signals
  • This electrical multimeter correctly measure pulse-width modulated motor drive signals
  • Save time: The 87V multimeter includes a built-in thermometer and temperature probe
  • True-RMS AC voltage and current for measuring non-linear signals

Product overview: Fluke 87V TRMS Industrial Multimeter

Fluke 87V TRMS Industrial Multimeter

The Fluke 87V TRMS Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment even in loud, high energy, and high altitude locations.

This digital multimeter takes the guesswork out of drive system troubleshooting. This electrical multimeter

includes a unique function for accurately measuring noisy at the VFD and at the motor terminals. Special shielding blocks high frequency, high-energy noise generated by large drive systems.

The Fluke 80 Series V of digital multimeters have improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment.

Other useful features

  • Rugged, high accuracy industrial electrical multimeter to measure current, voltage and frequency on complex variable frequency drive (VFD) signals
  • Offers true-RMS AC voltage and current for measuring non-linear signals
  • Captures intermittents as short as 250 µS
  • Safety rated CAT III 1000 V, CAT IV 600 V
  • Includes a built-in thermometer and temperature probe

Applications

For Application engineer / Plant engineer / Industrial electricians (Working with VSD’s) / Electrical engineer. In plant automation, Power distribution, Electro-mechanical equipment, Industrial electronics, Setting up / repairing, adjustable speed motor drives.

Includes

  • TL75 Test Leads
  • AC175 Alligator Clips
  • Holster
  • 9V Battery (Installed)
  • 80BK Temperature Probe

What's in the box:

  • Fluke 87V Industrial Multimeter
  • TL75 Test Leads (TL175 Eur)
  • AC175 Alligator Clips
  • Holster with tilt-leg, test lead storage
  • 80BK Temperature Probe
  • 9V Battery (Installed)

Specifications: Fluke 87V TRMS Industrial Multimeter

Specifications
Voltage DCMaximum voltage1000 V
Accuracy±(0.05% + 1)
Maximum resolution10 µV
Voltage ACMaximum voltage1000 V
Accuracy±(0.7% + 2) True RMS
AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution0.1 mV
Current DCMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(0.2% + 2)
Maximum resolution0.01 µA
Current ACMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(1.0% + 2) True RMS
Maximum resolution0.1 µA
ResistanceMaximum resistance50 MΩ
Accuracy±(0.2% + 1)
Maximum resolution0.1 Ω
CapacitanceMaximum capacitance9,999 µF
accuracy±(1% + 2)
Maximum resolution0.01 nF
FrequencyMaximum frequency200 kHz
Accuracy±(0.005% + 1)
Maximum resolution0.01 Hz
Duty cycleMaximum duty cycle99.9%
Accuracy±(0.2% per kHz + 0.1%)
Maximum resolution0.1%
Temperature measurement–200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe
80 BK temperature probe–40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
ConductanceMaximum conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum resolution0.01 nS
DiodeRange3 V
Resolution1 mV
Accuracy±(2% + 1)
Duty cycle rangeAccuracyWithin ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature–20 °C to + 55 °C
Storage temperature–40 °C to + 60 °C
Humidity (without condensation)0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating Altitude2000 m
Safety Specifications
Overvoltage categoryEN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvalsCE, CSA, RCM
Mechanical and General Specifications
Size201 x 98 x 52 mm (with holster)
Weight355 g
624 g – with holster
DisplayDigital6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog32 segments, updates 40/sec
Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery LifeAlkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010–1:2001
VibrationPer MIL–PRF–28800 for a Class 2 instrument

Models: Fluke 87V TRMS Industrial Multimeter

Fluke 87V
Fluke 87V Industrial Multimeter

Buy it

Includes:

  • TL75 Test Leads (TL175 EUR)
  • AC175 Alligator Clips
  • Holster
  • 9V Battery (Installed)
  • 80BK Temperature Probe

In resistance check mode, what is the maximum output voltage? Is it >8Vdc to test an IGBT gate? Thanks

Asked by: AWSt
The Fluke 87V Industrial Multimeter's specifications can be seen at the "specifications" tab on the product page: https://www.fluke.com/en-us/product/electrical-testing/digital-multimeters/fluke-87v
Answered by: FlukeCorporation
Date published: 2024-09-05

Does the units come with calibration certs?

Asked by: Mylene
To see if your product is supported for calibration, get a quote for calibration, or schedule a service order for repair or calibration visit https://flkext.fluke.com/OA_HTML/jtflogin.jsp or to see if your instrument is supported for calibration: Email: service@fluke.com Call: 1-800-87-FLUKE (1-800-873-5853)
Answered by: FlukeCorporation
Date published: 2024-08-21

which country does fluke 87v origin from?

Asked by: Yichao
The Fluke 87V is both designed and built in the U.S.A.!
Answered by: SuperFlyEDSguy
Date published: 2024-06-05

Are you able to use the Fluke 87-v to check voltage drop?

Asked by: NormHindy
Yes, depending on what kind of voltage you will be doing (how and on what voltage). If you want a graph of a voltage drop that would depend on the speed of the drop.
Answered by: FlukeCorporation
Date published: 2024-04-14

87V万用表怎么快速有效鉴别进口和国产,真假货怎么判断

Asked by: Anonymous

I sometimes have to work outside in the winter when temps occasionally drop below zero degrees Fahrenheit. Which multimeters will work in colder temps? Will They be slow?

Asked by: DK repair
  • y_2024, m_10, d_24, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_6
  • loc_en_US, sid_3739292368948, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 48.09ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from fluke 87V fluke is hands down the best of all the meters I have ever used
Date published: 2023-11-20
Rated 5 out of 5 by from Great Meter! Couple gripes.. I'm using this meter for electronics repair and love it! It's very accurate and has a nice loud continuity tone. And the tone isn't annoying either. However, there are a couple small grips I have. Including a safety manual instead of a user manual is not smart at all. Why not include the user manual and leave it up to the user to download the safety manual if they want? I'm honestly baffled by that choice... How do I get a printed manual? The 2nd gripe I have are the test leads. The price you pay I would have expected much better! They look and feel like a cheap pair of Chinese test leads. On top of that, why are the lead wires hard plastic instead of soft silicone? What year is this again? And when you use these test leads in the cold they become more rigid and hard to work with. Do yourself a favor and keep the leads in th box and buy a nice pair of probe master leads. Other than those 2 downfalls, I love the meter and is exactly what I wanted.
Date published: 2022-11-27
Rated 5 out of 5 by from Great meter I've had same 87 for over 10 years. Been dropped off ladders, leads getting caught on door handles where leads get ripped out of their sockets and various other types of abuse. Now I lost it. It's like losing my right hand. I'm a fire alarm tech. Best meter there is. Conductance feature is the best for finding those pesky intermittent grounds.
Date published: 2021-09-23
Rated 5 out of 5 by from My favorite Multimeter This is a fantastic tool. High quality, the best of the three multimeters I own. I use it every day, and it works flawlessly.
Date published: 2021-05-31
Rated 5 out of 5 by from Simply the best The best of the best - reliable, accurate and built to last…
Date published: 2021-05-30
Rated 5 out of 5 by from Trust I am a master electrician for over forty years. My life is of the up most importance. I trust my life with my Fluke 87V.
Date published: 2021-05-30
Rated 5 out of 5 by from Tip top I wanted the dmm with unparalleled accuracy and reliability of the Fluke 87. Its the last meter I'll buy!
Date published: 2021-01-12
Rated 5 out of 5 by from 87V because the 289 isn't a good choice. Although our use case is Electronic R&D I choose the 87 V, an industrial meter, over the 289. Yes, I could use the better precision of the 289 but the 87 V has a better reputation, longer battery life and 289's logging features don't work with Linux and are too cumbersome anyway.
Date published: 2020-12-01
  • y_2024, m_10, d_24, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_31, tr_130
  • loc_en_US, sid_3739292368948, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.31ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat