Fluke Calibration 9150 Thermocouple Furnace

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 110.89ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke Calibration 9150 Thermocouple Furnace

Key features

  • Stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.
  • With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter or as large as 1/2 inch.
  • Low-cost thermocouple furnace.
  • NIST-traceable calibration included.
  • RS-232 port standard

Product overview: Fluke Calibration 9150 Thermocouple Furnace

With a stability of ±0.5 °C, it has a temperature range to 1200 °C and a display accuracy of ±5 °C across its entire range.

With interchangeable temperature blocks, you can check thermocouples as small as 1/16 of an inch in diameter. The 9150 works with 115 or 230 VAC power.

9150 block hole sizes

The 9150 Thermocouple Furnace uses Fluke Calibration's own microprocessor-based controller for great stability and set-point accuracy. It has a removable well insert for versatility. It has rapid cool-down and heat-up times. And it comes with an RS-232 port for connection to a PC.

You can now afford to check your thermocouples with this excellent cost-effective instrument. Why pay more for features you don’t need and can’t use? Each unit is factory-calibrated and comes with test data and a calibration traceable to NIST.

Specifications: Fluke Calibration 9150 Thermocouple Furnace

General Specifications
Temperature range150°C to 1200°C
(302°F to 2192°F)
Display resolution0.1° to 999.9°
1° above 1000°
Stability±0.5°C
Display accuracy±5°C
Well diameter1.25 in(32 mm)
Well depth140 mm (5.5 in); (101 mm [4 in] removable insert plus 38 mm [1.5 in] insulator)
Heating time35 minutes to 1200°C
Cooling time140 minutes with block
Well-to-well uniformity±2.5°C (Insert “C” at 1200°C)
Stabilization20 minutes
Power115 V AC (±10%), 10.5 A or 230 V AC (±10%), 5.2 A, switchable, 50/60 Hz, 1200 W
Size (H x W x D)315 x 208 x 315 mm
(12.4 x 8.2 x 12.4 in)
Weight13 kg (28 lb)
NIST-traceable calibrationData at 150°C, 300°C, 450°C, 600°C, 800°C, 1000°C, and 1200°C

Models: Fluke Calibration 9150 Thermocouple Furnace

Fluke 9150-X
Fluke Calibration 9150 Thermocouple Furnace (specify X, X = A, B, C,or D included insert)

Buy it

Does Fluke 9150 is currently complying with the NRTL ?

Asked by: AlexHilton

What is the Duty Cycle of this unit? If I wanted to run it at 1200 for multiple days to test the drift or aging we would see, could this unit handle it?

Asked by: Jamesegan
  • y_2024, m_11, d_8, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_2
  • loc_en_US, sid_fluke-calibration-9150, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 109.19ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 25.1ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.