English

Fluke 726 Precision Multifunction Calibrators

Fluke 726 Precision Multifunction Calibrators is rated 3.7 out of 5 by 3.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.21ms
  • REVIEWS, PRODUCT
  • Fluke 726 Precision Multifunction Process Calibrator
  • Fluke 726 Precision Multifunction Process Calibrator 2

Key features

  • Precision multifunction, temp, frequency, voltage, and mA calibrator
  • Calibrates thermocouples and RTD temperature instruments
  • Stores up to eight calibration results in memory for analysis
  • Built-in 24 V Loop Power Supply

Product overview: Fluke 726 Precision Multifunction Calibrators

Process calibration designed specifically for process industries

The Fluke 726 is a precise and powerful, yet easy-to-use, field calibrator. It features broad workload coverage, calibration power, and unsurpassed accuracy needed by process professionals. It measures and sources almost all process parameters to calibrate almost anything. Use it to test sensors and valves, and to test and calibrate transmitters. The 726 interprets results without the help of a calculator and stores measurement data for later analysis.

Measurement capabilities

This precision multifunction calibrator measures volts, mA, pressure, RTDs, thermocouples, frequency, and resistance to test sensors and transmitters. The 726 also sources and simulates volts, mA, thermocouples, RTDs, frequency to calibrate transmitters. Measures and/or sources pressure using when paired with any of the 50 Fluke 750P series Pressure Modules to test and calibrate pressure transmitters and other devices. The 726 can also:

  • Source mA with simultaneous pressure measurement to conduct valve and I/P test
  • Conduct enhanced flowmeter testing with frequency totalizer and frequency pulse train source mode

Designed for ease of use

The 726 has built-in features that make it easier to use in nearly any measurement situation. From its ability to store frequently used test setups, to programming custom RTD probe calibration constants for enhanced temperature measurement, or the integrated voltage input protection design that improves reliability, the 726 is built to perform. The use of two separate channels even allows you to measure, source, or view process signals simultaneously. The backlit display provides better visibility in low-light conditions, and the standard 3-year warranty provides extra confidence that the 726 will be there when you need it to be.

You can also use the 726 to:

  • Capture the set, reset, and deadband of a pressure switch with the integrated switch test
  • Calculate the transmitter error % to interpret calibration results without the use of a calculator
  • Perform fast linearity tests with the auto-step and auto-ramp features
  • Power a transmitter during test using 24 V loop supply and simultaneous mA measurement

If you want documenting and HART communication built into your calibrator, consider the Fluke 754 Documenting Process Calibrator with HART.

What's in the box:

  • Fluke 726 Precision Multifunction Process Calibrator
  • (1 set) AC72 alligator clips
  • (1 pair) stackable test leads
  • (1 pair) TL75 test leads
  • NIST- traceable calibration report and data
  • Quick Reference Guide
  • 3-year warranty

Specifications: Fluke 726 Precision Multifunction Calibrators

Measurement Accuracy
Voltage DC30.000 V0.01% + 2 mV (upper display)
20.000 V0.01% + 2 mV (lower display)
90.00 mV0.01% + 10 μV
-10.00 mV to 75.00 mV0.025% + 1 count (via TC connector)
Current DC24.000 mA0.01%+ 2 mA
Resistance0.0 to 4000.0 Ω± 0.015%
Frequency2.0 to 1000.0 CPM0.05% + 0.1 cpm
1.0 to 1000.0 Hz0.05% + 0.1 Hz
1.00 to 15.00 kHz0.05% + 0.01 kHz
Sensitivity1 V peak-to-peak-minimum
Pressure

Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.

Source Accuracy
Voltage DC100.00 mV0.01% + 10 μV
20.000 V0.01% + 2 mV
-10.00 mV to 75.00 mV0.025% + 1 count (via TC connector)
Current DC24.000 mA (Source)0.01% + 2 μA
24.000 mA (Simulate)0.01% + 2 μA
ResistanceRange, accuracy (percent of reading + floor) and excitation current5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA
5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA
400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA
1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA
Frequency2.0 to 1000.0 CPM0.05%
1.0 to 1000.0 Hz0.05%
1.0 to 10.0 kHz0.25%
10.0 to 15.0 kHz0.5%
Waveform5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure and source accuracyCu101.8°C
NI-1200.15°C
PT-100 (385)0.45°C
PT-100 (392)0.35°C
PT-100 (391-JIS)0.35°C
PT-200 (385)0.95°C
PT-500 (385)0.55°C
PT-1000 (385)0.35°C
RTD Resolution0.01°C (0.01°F)
Cu10.01 C0.1°C (0.1°F)
J0.4°C
K0.5°C
T0.4°C
E0.4°C
R1.4°C
S1.4°C
B1.4°C
L0.45°C
U0.45°C
N0.6°C
XK0.4°C
BP1.1°C
TC ResolutionJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
Specifications
Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature
RampsSlow ramp, Fast ramp, 25% step-ramp
Loop power functionVoltage24 V
Accuracy10%
Maximum current22 mA, short circuit protected
Step functionsSource functionsVoltage, current, resistance, frequency, temperature
Steps25% of range, 100% of range
Environmental Specifications
Operating temperature-10°C to +55°C
Storage temperature-20°C to +71°C
Operating altitude3000 m
Safety Specifications
Agency approvalsEN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Mechanical and General Specifications
Size200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in)
Weight650 g (23 oz)
Batteries4 AA alkaline batteries
Battery replacementSeparate battery compartment, accessible without breaking calibration seal
Side port connectionsPressure module connector, also used for remote real-time programming

Models: Fluke 726 Precision Multifunction Calibrators

Fluke 726
Fluke 726 Precision Multifunction Process Calibrator

Includes:

  • One set of AC72 alligator clips
  • One set of stackable test leads
  • One set of TL75 testleads
  • User manuals
  • NIST- traceable calibration report and data
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.19ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 5 out of 5 by from Portable and powerful I bought this calibrator 6 months ago. It is very convenient to make typical operations and more convenient than Fluke 725 calibrator. I don't need the user manual almost at all operations, I just do my work. But there are some questions to the Fluke 726 calibrator. 3- or 4-wire RTD measurement is not so easy because you have to connect "+mA" terminal (red) and "COM" terminal (black) to the low end and "-mA" terminal and "V" terminal to the high end of the resistor. It is annoying me. Typical 3-wire connections use two wires to the high end and one wire to the low end of the resistor. Fluke 726 connection with reverse wire order doesn't look trivial.
Date published: 2019-06-14
Rated 1 out of 5 by from Fluke 726 I replaced the battery and the numbers froze on the screen and then I try to turn it back on it wouldn't come on at all it wwas in my trunk I don't know why it wouldn't come on
Date published: 2017-08-14
Rated 5 out of 5 by from Great Multifunction Calibrator We have been using model 725 and 726 Fluke Multifunction Calibrators for over 8 years now. This is a simple and user friendly instrument that I carry on my tool case on a daily basis. We recommend this product greatly, we have been working with Fluke products for over 25 Years.
Date published: 2016-12-08
  • y_2024, m_10, d_14, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_3840953483316, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.22ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.