Electrical Calibration Workload Matrix
Use this guide to help choose the right electrical calibrator for your application.
This guide summarizes the functions, accuracies and targeted workload of every Fluke Calibration electrical calibrator; including electrical multi-product calibrators, multifunction calibrators, oscilloscope calibrators, electrical tester calibrators, power and energy calibrators and standards, and precision process calibrators. This selection guide is intended to help you decide which calibrator best fits which class of test equipment and the associated performance levels required.
For additional help selecting an electrical calibrator,
| Multi-Product Calibrators | Multifunction Calibrator | Oscilloscope Calibrator | Electrical Tester Calibrator | Temperature/Pressure Calibrator | ||||
| Workload | 5530A | 5540A | 5550A | 5560A | 5730A | 9500C | 5322A | 7526A |
| DMMs | ||||||||
| Basic DC V accuracy at 99 % | 31 ppm | 31 ppm | 11 ppm | 8 ppm | 4.5 ppm | n/a | 1000 ppm | 40 ppm |
| Analog / Panel Meters | • | • | • | • | • | V DC and V AC | V DC, I DC and R | |
| 3.5 digits (typ. ± 0.3 % DC V) | • | • | • | • | • | V DC and V AC | V DC and V AC | |
| 4.5 digits (typ. ± 0.025 % DC V) | • | • | • | • | • | |||
| 5.5 digits (typ. ± 0.015 % DC V) | • | • | • | |||||
| 6.5 digits (typ. ± 0.0030 % DC V) | • | • | ||||||
| 7.5 digits (typ. ± 12 ppm DC V) | • | |||||||
| 8.5 digits (typ. ± 3.9 ppm DC V) | • | |||||||
| Temperature/Pressure | ||||||||
| RTD simulate | • | • | • | • | • | |||
| RTD measure | • | |||||||
| Thermocouple simulate | • | • | • | • | • | |||
| Thermocouple measure | • | • | • | • | • | |||
| Pressure modules | • | |||||||
| Oscilloscopes | 1 Channel | 1 to 5 Channels | ||||||
| Up to 600 MHz | 600 MHz Opt | 600 MHz Opt | 600 MHz Opt | 9540C Head opt | ||||
| Up to 1.1 GHz | 1.1 GHz Opt | 1.1 GHz Opt | 9540C Head opt | |||||
| Up to 2.1 GHz | 2.1 GHz Opt | 9540C Head opt | ||||||
| Up to 4.2 GHz | 9540C Head opt | |||||||
| Safety Testers | ||||||||
| Hipot | • | |||||||
| Megohm meters | • | |||||||
| Installation | • | |||||||
| PATs | • | |||||||
| Continuity | • | |||||||
| Loop impedance | • | |||||||
| Leakage current | • | |||||||
| Ground bond | • | |||||||
| RCD/GFCI | • | |||||||
| Medical safety | • | |||||||
| Power/Energy | ||||||||
| Wattmeters | • | • | • | |||||
| Harmonic analyzers | ||||||||
| Flicker meters | ||||||||
| Phase angle meters | • | • | • | |||||
| Power analyzers | • | • | • | |||||
| Power recorders | • | • | • | |||||
| Secondary energy standards | ||||||||
| Watt-hour/energy meters | • | • | • | |||||
| Other | ||||||||
| Clamp meters | • | • | • | • | ||||
| LCR meters | RC only | RC only | LRC | LRC | ||||
| Process calibrators | • | • | • | • | ||||
| Data acquisition | • | • | • | • | ||||
| Non sine waveforms | • | • | • | • | ||||
| RF millivolt meters | 30 and 50 MHz WB opt | |||||||
| Extend current to 120A AC, 100A DC with 52120A | • | • | • | • | • | Manual Only | ||
| MET/CAL Compatible | • | • | • | • | • | • | • | • |
• = Capable
Specifications subject to change without notice.