Procurar Resultados

Nenhum resultado de pesquisa disponíveis:
Found 104 results containing the words:support
  • Fluke 744 Documenting Process Calibrator-HART

    The 744 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device.

    Produtos
  • Kit com traçador de curva I-V PVA-1500HE2 e medidor de isolamento 1537 de 2500V

    Otimize o desempenho solar: Analisador fotovoltaico PVA-1500HE2 e medidor de isolamento 1537 de 2500V

    Produtos
  • Kit de alicate, multímetro e traçador de curva I-V PVA-1500HE2

    Otimize o desempenho solar: Analisador fotovoltaico PVA-1500HE2, alicate amperímetro 393 FC e multímetro 87V

    Produtos
  • Kit de traçador de curva I-V, isolamento, alicate e multímetro PVA-1500HE2

    Otimize o desempenho solar: Analisador fotovoltaico PVA-1500HE2, multímetro para isolamento 1587 FC, alicate amperímetro 393 FC e multímetro 87V

    Produtos
  • COMPASS® for Pressure

    O COMPASS® for Pressure é uma plataforma universal para todas as suas necessidades relacionadas ao software de calibração de pressão.

    Produtos
  • Analisador fotovoltaico da série PVA-1500, traçador de curva I-V

    Optimize Solar Performance: PVA-1500HE2 PV Analyzer & TiS75+ Thermal Camera

    Produtos
  • Fluke TruTest™ Data Management and Reporting Software

    The easy-to-use data management and reporting solution.

    Produtos
  • O Calibrador de Potencia Trifasico 6003A

    O calibrador de potência trifásico 6003A é o modo mais econômico de obter a precisão e desempenho superiores em um instrumento de três fases independentes.

    Produtos
  • Procedimentos garantidos para o MET/CAL®

    Os procedimentos garantidos do MET/CAL® são procedimentos de calibração opcionais para o MET/CAL® Plus software de calibração do MET/CAL®

    Produtos
  • MS-PSWD - Serviço de reconstrução de senha do administrador

    As atividades de administradores nos sistemas MET/CAL®, 5500/CAL e MET/TRACK® estão limitadas a atividades relacionadas ao sistema.

    Produtos
  • MS-MIGRATE - Assistência à migração de banco de dados

    Assistência a migração de banco de dados

    Produtos
  • MS-DBFIX - Recuperação de dados de banco de dados corrompido

    Recuperação de dados a partir de banco de dados corrompido

    Produtos
  • Software de gerenciamento de calibração MET/CAL® (com o software MET/TEAM®)

    Os laboratórios de calibração enfrentam diversos desafios: uma carga de trabalho crescente e mais complexa; menos técnicos; uma lista crescente de padrões de qualidade. Acima de tudo, existe uma pressão constante para redução dos custos. O software Fluke Calibration ajuda a responder a tais desafios ao calibrar e gerenciar sua carga de trabalho com mais eficiência e uniformidade.

    Produtos
  • MET/SUPPORT Gold para MET/CAL Plus

    Entre em contato com a linha direta MET/SUPPORT Gold de segunda a sexta-feira, das 8h às 16h30, horário do Pacífico (Estados Unidos, Canadá, México, América Central e América do Sul) ou horário do Meridiano de Greenwich (Europa) para falar com um dos nossos especialistas em software altamente qualificado

    Produtos
  • Software de validação de temperatura TQSoft e TQAero

    Coleta de dados regulamentada com o FDA 21 CFR Part 11 e o AMS 2750

    Produtos
  • Informações importantes para titulares de contas MET/SUPPORT

    A Fluke Calibration agora está no fluke.com! Fizemos várias atualizações importantes para melhorar a experiência do cliente e a qualidade do serviço. As principais mudanças incluem:1. Registro no MET/SUPPORT Gold: Para aproveitar ao máximo sua conta MET/SUPPORT Gold, você precisa registrar sua conta no site fluke.com. Para isso, você precisa do seu número MET/SUPPORT Gold e do PIN, que são enviados para você por e-mail após a compra. O registro dá acesso a suporte técnico prioritário,...

    Artigo
  • END OF SERVICE NOTICE: 1590 and 1575A Super Thermometers

    END OF SERVICE NOTICE: 1590 and 1575A Super Thermometers (130.61 KB)February 20, 2020 To Fluke Calibration’s 1590 and 1575A Super Thermometer owners: It has been 10 years since the end of life for the 1590 and 1575A Super Thermometers, and Fluke is now announcing the end of service for these obsolete versions of the Super Thermometer will take place on June 30, 2020. Please see  below for the full lifecycle of the products. Fluke model: 1590Introduction: 1998End of life: January 2010End of...

    Artigo
  • Release: MET/CONNECT version 2.2.0 (with MET/CAL version 11.1.0)

    MET/CONNECT v 2.2.0 with MET/CAL v 11.1.0 (2.1 GB)   Document(s): MET/CONNECT 2.2.0 ReadMe (154.98 KB) MET/CAL 11.1.0 ReadMe (450.51 KB) MET/CONNECT Installation Guide (722.31 KB) MET/CONNECT API Reference (825.91 KB) Current MET/CONNECT Customers: What you need to know prior to updatingThe MET/CONNECT version 2.2.0 and MET/CAL version 11.1.0 release is an update to previous MET/CONNECT and MET/CAL software. This update includes new features, bug fixes, and minor updates.This installer can...

    Artigo
  • 5560A/5550A/5540A Firmware

    5560A/5550A/5540A Firmware (update)What’s NewThe latest firmware updates for the Fluke 5560A/5550A/5540A bring some sought-after features that customers have requesting. The full list of key changes can be found below, but here are a few new additions to highlight:Control up to three 52120A Transconductance Amplifiers via rear panel connectorUsing the rear panel connector on your Fluke 5560A/5550A/5540A, you can now remotely control up to three 52120A Transconductance Amplifiers through your 5560A/5550A/5540A...

    Artigo
  • END OF SERVICE NOTICE: 5800A and 5820A

    END OF SERVICE NOTICE: 5800A and 5820A (222.96 KB)February 4, 2020To Fluke Calibration’s original 5800A and 5820A owners:Today Fluke is notifying you that the extended repair and calibration support period for the 5800A and 5820A calibrators is ending June 30th, 2020. This date is well beyond the five years of extended support Fluke Calibration offers after discontinuing a product’s manufacture (End of Life). Please see the table below for the full lifecycle of the products.Year ofFluke ModelIntroductionEnd...

    Artigo
  • Humidity Calibration and Repair Services

    Fluke Calibration provides calibration and repair services for humidity calibration equipment through our accredited calibration laboratories in American Fork, Utah (5128A RHapid-Cal® Humidity Generator and 1620A Digital Thermometer-Hygrometer) and Phoenix, Arizona (2456-LEM Laboratory Equipment Monitor). Our prices and turnaround times are competitive and our quality and capabilities are unmatched.For more information about these services or to request a quote, call 877-355-3225 or email us at...

    Artigo
  • Hart Scientific Temperature Calibration

    Hart Scientific temperature calibration is part of Fluke CalibrationHart Scientific has been a member of the metrology community for over 30 years. Now, under the Fluke Calibration name, it continues to be a leading manufacturer of temperature calibration and measurement equipment. Our experience in temperature calibration goes back 30 plus years and, as Fluke Calibration, we will still be here 30 years from now.Our customers include metrologists, engineers, technicians, researchers, and quality...

    Artigo
  • DH Instruments (DHI) Pressure and Flow Calibration

    DH Instruments pressure and flow calibration is part of Fluke CalibrationDH Instruments (DHI) was founded in 1980 with one objective: to provide superior calibration solutions through innovative technology, first rate service, and uncompromisingly metrological integrity.  Now, under the Fluke Calibration name, those values and the DH Instrument commitment to excellence remain the same.DH Instruments customers include metrologists, engineers, technicians, researchers, and quality professionals worldwide...

    Artigo
  • Temperature Calibration and Repair Services

    IntroductionFluke Calibration provides calibration and repair services for the former Hart Scientific line of temperature calibration equipment. Calibration and repair services for baths and industrial calibrators are provided in Everett, Washington, while digital thermometer readouts, 4180 and 4181 infrared calibrators, temperature probes (SPRTs, PRTs, thermistors, reference thermocouples) and other reference standards are calibrated and serviced in American Fork, Utah.Complete an online request...

    Artigo
  • Flow Calibration and Repair Services

    Fluke Calibration offers flow calibration and repair services in the US through our accredited calibration laboratory in Phoenix, Arizona. Our prices and turnaround times are competitive, and our quality and capabilities are unmatched.Complete an online request for service form.Service Request (RMA)Need help submitting an online Service Request (RMA)? Watch this brief Quick Start Video. We've also prepared a Getting Started Guide.For more information about these services or to request a quote call...

    Artigo
  • FLUKE-17XX, Flat Cable, Voltage Test Lead 3-phase+N Recall Form Submitted

    Dear Customer, Thank you for registering your product(s) as part of our product safety recall of your FLUKE-17XX, Flat Cable, Voltage Test Lead 3-phase+N (Recalled Cable). We have received your information, and your order is in process. We will soon be sending you a cable replacement to correct your Recalled Cable(s). A Fluke representative may contact you shortly if more information is needed. Please accept our most sincere apologies for any inconvenience caused by this action and should you have...

    Artigo
  • MET/TEAM® v3.3 and MET/CAL® v11.0 Software: Minimum recommended system requirements

    Minimum recommended system requirementsMET/TEAM server*  SQL DatabasesOperating SystemsSQL Server 2012SQL Server 2014SQL Server 2016SQL Server 2017SQL Server 2019SQL Server 2022Windows 10√√√√√√Windows 11Not supportedNot supportedNot supported√√√Windows Server 2016Not supported√√√√√Windows Server 2019Not supported√√√√√Windows Server 2022Not supportedNot supportedNot supported√√√*Home, Home Basic, Home Premium, and Core editions of Windows are not supported.Database...

    Artigo
  • LEMCal Laboratory Environment Monitor software

    LEMCal Laboratory Environment Monitor software (.zip)Requirements:Microsoft® Windows® 95 or higher (Windows 7 32-bit and 64-bit are supported)1.6 MB of available hard disk space,32 MB RAM,RS-232 or RS-485 portInterface includes extensive help and system manual includes syntax commands.Unzip the downloaded file and click on LemCAL.exe to install.Version 1R08File size: 4 MB

    Artigo
  • molbox RFM™ v1.20d Embedded Software

    molbox RFM™ v1.20d Embedded Software (.bin)TITLEVERUSE WITHmolbox RFM™1.20d2011.10.17molbox RFMTITLEVERUSE WITHmolbox RFM™1.20d2011.10.17molbox RFMInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of...

    Artigo
  • molbox1 v5.41 Embedded Software

    molbox1 v5.41 Embedded Software (.bin)TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1TITLEVERUSE WITHmolbox1™5.412016.12.16molbox1Instructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.The updating of embedded software should...

    Artigo
  • 6270A Embedded Software, Update by USB

    6270A Embedded Software, Update by USB (.zip)Additional Downloads:6270 PCM v104 USB (.zip)Click here to update by serial RS-232 port.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 6270AUpdating the PCM (Pressure...

    Artigo
  • 9142/9143/9144 ver 1.35 firmware update

    9142 US/EU ver 1.35 firmware update (.zip)Additional Downloads:9142 Asia ver 1.35 firmware update (.zip)9143 US/EU ver 1.35 firmware update (.zip)9143 Asia ver 1.35 firmware update (.zip)9144 US/EU ver 1.35 firmware update (.zip)9144 Asia ver 1.35 firmware update (.zip)Download appropriate file from above. See "Instructions" below to determine correct file. Title914x Ver 1.35 UpdateVer1.35/1.35Use withAll 9142/9143/9144 Field Metrology Wellswith internal reference readout (–P option)Date Modified18-May-2012Description...

    Artigo
  • CalTool for Analog Free Utility

    CalTool for Analog Free Utility (.exe)TITLEVERUSE WITHDOCUMENTSCalTool™ for Analog Free Utility1.00TITLEVERUSE WITHDOCUMENTSCalTool™ for Analog Free Utility1.002003.01.27molbox1 (w/MFC option installed) & MFC-CBHelp File IncludedInstructions:Download and run the file. The installation program will prompt you through the process.DescriptionCalTool™ for Analog is used to calibrate the analog circuits of molbox1 and MFC-CB. CalTool for Analog is PC based application that assists in the calibration...

    Artigo
  • 917X Firmware

    9170 Firmware (.zip)Additional Downloads:9171 Firmware (.zip)9172 Firmware (.zip)9173 Firmware (.zip)Title:917X FirmwareVersions:9170: Ver. 1.209171: Ver. 1.209172: Ver. 1.209173: Ver. 1.20Use with:All 9170, 9171, 9172 and 9173Date Modified:1/1/2012Download Requirements:          Locate a computer with an available RS-232 COM port, with Windows XP or newer operating system.Locate an RS-232 Null modem cable and connect one end of the cable to the instrument, the other end to the RS-232 serial...

    Artigo
  • COMPASS® for Pressure Version 4 Release Notes

    Download COMPASS® for PressureVersion 4 Releases4.2 (2012.07.27)ADDCP-115%4COMPASS for Pressure now supports the calibration functions of CalTool for RPTs. This functionality allows users to fully adjust and report calibration results for supported Fluke products. Sample tests are included with COMPASS that support automated collection of as received data and as left data with an adjustment in between. Review the CalTool for RPTs application note for details. The COMPASS CalTool implementation supports...

    Artigo
  • COMPASS® for Pressure Version 3 Release Notes

    Download COMPASS® for PressureVersion 3 Releases3.00.43 (SP1) (2011.02.11)ADDCP-802Support PG7000 and PG9000 models that respond with FLUKE as the manufacturer.CHGCP-793An automated PG7000/PG9000 system with a PPC and AMH will use ATM as the minimum pressure when exercising in a test that is run in Absolute by ATM.3.00.42 (SP1) (2010.07.07)ADDCP-689Support alternate units of measure and temperature references for the Piston Cylinder effective area.ADDCP-775Added new instruments to the default database.CHGCP-786When...

    Artigo
  • GFSTools PC Based Software

    GFSTools PC Based Software (.exe)TITLEVERUSE WITHGFSTools™1.012010.12.03GFS 2102DescriptionGFS Tools is a PC based application used to operate the GFS 2102 Gravimetric Flow Standard.  SummaryGFS Tools is the PC based interface to the GFS 2102. All necessary features are included to log data for up to 2 DUTs in comparison to the GFS from 1 sccm of N2 to 10 slm of N2. Options are provided to set manual or automatic flows using an MFC and to define a test sequence of flow points to fully automate...

    Artigo
  • Hot Fix: MET/CAL version 10.1.0 Hot Fix

    Hot Fix: MET/CAL version 10.1.0 Hot Fix (.zip)Documents:MET/CAL version 10.1.0 Hot Fix Readme (.pdf)This hot fix applies to both MET/TEAM and MET/CONNECT versions of MET/CAL.For additional information on applying this Hot Fix, see the following article on our support knowledge base: How to Get and Apply the MET/CAL 10.1.0 Hot FixCurrent MET/CAL Customers:The MET/CAL 10.1.0 Hot Fix release is an update to previous MET/CAL software. This update includes bug fixes only.This download does not include...

    Artigo
  • molLoad Free Utility

    molLoad Free Utility (.exe)TITLEVERUSE WITHmolLoad™ Free Utility1.01amolbox1, molbox RFMTITLEVERUSE WITHmolLoad™ Free Utility1.01amolbox1, molbox RFMInstructions:Download and run the file. The installation program will prompt you through the process.DescriptionSelf extracting installation file for the molLoad molbloc EEPROM restore utility.SummaryInstructions: molLoad will only install on 32-bit Microsoft Windows operating systems. Do not attempt to install on a Windows 64-bit operating system...

    Artigo
  • COMPASS for Flow PC Based Software Download/Upgrade

    COMPASS for Flow PC Based Software (.exe)Additional Downloads:COMPASS for Flow, PC Based Software, Demo (.exe)COMPASS for Flow, PC Based Software, Upgrade (.exe)Patch to use COMPASS for Flow 4.0 with MET/TRACK 7.3 SP1 (.zip)Patch to use COMPASS for Flow 4.0 with MET/TRACK 8.X (.zip)TITLEVERUSE WITHDOCUMENTSCOMPASS®for Flow™5.1.0molbox1, molbox1+, molbox1+S, molbox RFM, MFC-CB, MFC SwitchboxCOMPASS for Flow uses an on line HTML help system that is installed with the program. Install and run COMPASS...

    Artigo
  • 8270A/8370A Embedded Software

    8270A/8370A Embedded Software (.zip)TITLEUSE WITH8270A/8370A8270A/8370AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the USB port on the rear panel of the 8270A/8370AUpdating the firmware (embedded software) of an 8270A or 8370A pressure controller requires only a...

    Artigo
  • COMPASS for molbox PC Based Software Download/Upgrade

    COMPASS for molbox PC Based Software Demo (.exe)COMPASS for molbox PC Based Software Upgrade (.exe)TITLEVERUSE WITHCOMPASS®for molbox™4.062010.10.28TITLEVERUSE WITHCOMPASS®for molbox™4.062010.10.28molbox1, molbox1+, molbox RFMDescriptionThis download file provides 100 hours of fully functioning use of COMPASS for molbox. Licensed users can download this file to upgrade from a previous version of COMPASS for molbox.  SummaryCOMPASS for molbox is a complete flow calibration software package...

    Artigo
  • CalTool for RPTs Free Utility

    CalTool for RPTs Free Utility (57.61 MB)TITLEVERUSE WITHDOCUMENTSCalTool™ for RPTs Free Utility1.10.0.252021.05.11PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCK, PPCK+, RPM1, RPM3, RPM4, PPCH, PPCH-G, molbox1, molbox RFMCalTool for RPTs uses an on line HTML help system that is installed with the program. Install and run CalTool then select the [Help] menu to access the help system.(Note: As a result of PC specific security settings the help may not display correctly when viewed over the Internet....

    Artigo
  • CI Editor PC Based Free Utility

    CI Editor PC Based Free Utility (.exe)Additional Downloads:Mensor 400 CI Definition (.ci)Mensor 600 CI Definition (.ci)DH Instruments PPC2+ CI Definition (.ci)DH Instruments PPC2+ CI Definition (.ci)Ruska 6000 CI Definition (.ci)All Ruska models that support the SCPI command syntax (.ci)TITLEVERUSE WITHDOCUMENTSCI Editor™1.002009.03.06PPC4See CI Editor [Help] menu to access the help system.Instructions:The CI Editor is used to maintain CI Definitions for the PPC4.Download and run the file. The...

    Artigo
  • 6270A Embedded Software, Update by Serial RS-232 Port

    6270A Embedded Software, Update by Serial RS-232 Port (.zip)Click here to update by USB.TITLEUSE WITH6270A6270AThe updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center.If the update isn't performed properly, your product may be inoperable until it is.Instructions to update by the RS-232 serial port on the rear panel of the 6270AThe below procedure updates the main firmware. Updating...

    Artigo
  • 1529 Firmware Update v. 2.04/1.00

    1529 Firmware Update v. 2.04/1.00 (.zip)Title:                  1529 Main FirmwareVer:                    2.04/1.00Use with:           1529Date Modified:  9/5/2012Description of the change: NoneDownload Requirements:          Locate a computer with an available RS-232 COM port, with Windows XP or newer operating system.Locate an RS-232 Null modem cable and connect one end of the cable to the instrument, the other end to the RS-232 serial...

    Artigo
  • How to Accurately Calibrate a Hygrometer

    Get step-by-step instructions on how to accurately calibrate a hygrometer or other humidity sensor including why it’s important, techniques, and tips.

    Artigo
  • Fluke 1773, 1775 and 1777 Power Quality Analyzers Software and Firmware

    .sub-title { padding-top: 10px; } .warning { padding: 0 30px; } .hr-warning { margin: 25px 0px 30px 0px; font-size: 1px; line-height: 1px; border-top: 0px solid #ffffff; border-right: 0px solid #ffffff; border-bottom: 1px solid #000000; border-bottom-color: #000000!important; border-left: 0px solid #ffffff; } Fluke Energy Analyze PlusFluke Energy Analyze Plus application software for download, analysis and reporting. Used with Fluke 1730, 1732, 1734, 1736, 1738, 1742, 1746, 1748, 1773, 1775 and...

    Artigo
  • 1620A Firmware Update v. 1.15

    1620A Firmware Update v. 1.15 (.exe)Title:1620A Firmware UpdateVer:1.15Use with:All 1620ADate Modified:7/23/2013Description of the change: NoneDownload Requirements:          Locate a computer with an available RS-232 COM port, with Windows XP or newer operating system.Locate an RS-232 Null modem cable and connect one end of the cable to the instrument, the other end to the RS-232 serial port on the computer. Note: If your computer only has USB serial interface, an adapter from USB...

    Artigo
  • IR Configuration Utility

    The IR Configuration Utility includes an export feature that will allow you to save the information for custom configurations to a file.

    Artigo
  • How to choose a blackbody or Infrared temperature calibrator

    Though the principle of radiation thermometry has been used in industry for decades, its recent growth in the HVAC, factory maintenance, aerospace, and energy industries is causing many people to inquire about infrared (IR) thermometers and the calibration equipment needed to support them

    Artigo
  • Infrared Temperature Calibration 101

    Learn the basics of infrared temperature calibration including how infrared thermometers work, emissivity, blackbodies, detecting radiance & more.

    Artigo
  • How End-of-Life Calibrators Can Help You Upgrade to the Newest Technology and Reduce Production Risks

    Owning an end-of-life calibrator presents risks to your business or workflow & can prevent you from leveraging the latest technology. Learn more here.

    Artigo
  • Three Reasons to Consider a Modular Pressure Control System

    Learn the most common reasons why someone might upgrade to a modular pressure control system for their existing calibration standards.

    Artigo
  • Now You Can Use MET/CAL™ Software by Itself or With the Asset Management Software of Your Choice

    Learn how MET/CONNECT Calibration Integration Software allows you to use MET/CAL Software without an asset management application or with the one of your choice.

    Artigo
  • How to calibrate your PT100 temperature sensor and other probes in-house

    Learn 3 ways to calibrate a PT100 and a basic, 5-step procedure. Also discover how to bring calibration in house along with the benefits and challenges.

    Artigo
  • Commonly Asked Questions about the 8270A and 8370A High-Pressure Controllers

    Get answers to common questions about the safety of a high-pressure supply & the capabilities of the Fluke 8270A/8370A High-Pressure Controller/Calibrator.

    Artigo
  • How to avoid contamination in pressure calibration

    Discover Fluke resources on how & why to prevent contamination in pressure calibration including videos, webinars, and blog posts. Learn more here.

    Artigo
  • Wim Sibon’s MET/CAL Journey

    The first version of MET/CAL that I saw was version 0.86 – it was a pre-release. I was working at the Fluke/Philips service center from 1990 to 1994, here in Holland. In the beginning of the 90’s in this lab they started using MET/CAL, starting on very simple PCs, now it is one of the most advanced labs in using MET/CAL.

    Artigo
  • ISO/IEC 17025:2017 Training Online

    Fluke Calibration offers free, online ISO 17025 training to address the 2017 changes in the form of this article and training webinars. Get the info here.

    Artigo
  • How traceability is restored to infrared calibration

    Find out how traceability of infrared thermometers is impacted by the traditional approach to servicing IR calibrators.

    Artigo
  • The Truth About Height Based Pressure Units

    When does height equal pressure? Well the simple answer is it doesn't, but more on that later. A less simple answer is that height based pressure unit standards for manometers have evolved significantly over time. This has left an interesting legacy that you need to be aware of if you calibrate pressure instruments using height based units.

    Artigo
  • Getting to “Yes”: How to justify the purchase of new calibration equipment

    Worried your boss won't approve a needed calibrator purchase? Learn and get the resources here to show why the purchase can be a smart business decision.

    Artigo
  • Unit of Measure Converter Free Utility

    Unit of Measure Converter Free Utility (.exe)TITLEVERUSE WITH Unit of Measure Converter Free Utility2.01a2006.08.15All Products Instructions:Download and run the file. The installation program will prompt you through the process.DescriptionThe Unit of Measure Converter is a free ActiveX control distributed by Fluke Calibration. This program can be run stand alone or built into other applications. Use the [Show Help] menu choice for details on using this tool.Warning - Fluke Calibration has made...

    Artigo
  • RPM4-AD v1.00f Embedded Software

    RPM4-AD v1.00f Embedded Software (.bin)TITLEVERUSE WITHNOT FOR USE WITHRPM4-AD™1.00f2010.12.28RPM4-ADDo NOT use with NON "-AD" (Air Data)RPM4 ModelsInstructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an...

    Artigo
  • Why is Calibration Important?

    Table of ContentsWhy is calibration important?The importance of calibration in the futureDifferent perspectives on the significance of calibrationThe benefits and purpose of calibrationWhat are the costs and risks of not calibrating?Summary / TL;DRWhy is calibration important?Calibration is important because it helps ensure accurate measurements, and accurate measurements are foundational to the quality, safety and innovation of most products and services we use and rely on every day.Few people realize...

    Artigo
  • How to Calibrate a Pressure Gauge with the Fluke 8270A High-Pressure Controller Calibrator

    Hi, this is Jeff Grossman, Sales Engineer for Fluke Calibration’s pressure and mass flow calibration solutions, here to provide you with a demonstration of one of our three modular pressure controllers. I happen to have here the 8270A which has a maximum pressure of 6000 psi complemented by the 6270A maximum pressure of 3000 psi and the 8370A with maximum pressure of 15,000 psi. The nice thing is they share a lot of commonality which makes them easy to switch between and easy to use.Very small...

    Artigo
  • Temperature calibration: Tips and tricks from the real world

    Anyone who has been in the calibration business for as long as we have knows that experience is priceless. Time has a way of teaching you what works and what doesn’t. When things are working right, the cal lab may not be a very exciting place, but it does mean you did your job. So, here are a few tips and tricks you can use to keep things up and running:The truth about calibrating temperature sensorsCalibration baths usually deliver the best resultsBoost productivity with multiple calibration bathsProtect...

    Artigo
  • What is the HART protocol?

    HART (Highway Addressable Remote Transducer) Protocol is an open standard used globally to send and receive digital information using analog wiring between smart devices and control systems. With over 30 million devices installed, it is the most popular protocol used in the field. HART was first available in the late 1980s and quickly gained in popularity mainly due to its ability to continue to support the older 4-20 mA analog protocol while adding the significant benefits of digital smart instrumentation.The...

    Artigo
  • PG7000 Ver 2.07h Embedded Software

    PG7000 Ver 2.07h Embedded Software (.bin)TITLEVERUSE WITHPG7000™2.07hAll PG7000 Series modelsInstructions:-Ver 2.02x and 2.03x Users You can upgrade directly to this version with no special considerations.-Ver 2.01x UsersVer 2.02 is a major revision which should be accompanied by hardware changes.-Ver 1.0x UsersVer 2.01 is a major revision which should be accompanied by hardware changes. Contact a Fluke Calibration Authorized Service Center for additional information.Download the file. Run Winflash and...

    Artigo
  • PG7000/PG9000 Ver 3.1.5.255 Embedded Software

    PG7000/PG9000 Ver 3.1.5.255 Embedded Software (.bin)TITLEVERUSE WITHPG7000™PG9000™3.1.5.255All PG7000 models with SN 733 or newer. All PG9000 models.TITLEVERUSE WITHPG7000™PG9000™3.1.5.255All PG7000 models with SN 733 or newer. All PG9000 models.Instructions:The PG7000/PG9000 firmware versions 3.00 and newer are intended to work with all PG9000 models and PG7000 models with serial numbers 733 or newer. Do not attempt to upgrade an older PG7000 model with this software. This upgrade does not...

    Artigo
  • Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0)

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You may upgrade from either version 3.0.0 or 3.1.0 directly to version 3.1.1.Upgrading from version 3.0.0 or 3.1.0 of MET/TEAM will not require you to re-request your...

    Artigo
  • Release: MET/TEAM version 3.2.0 (with MET/CAL version 10.6.0)

    Release: MET/TEAM version 3.2.0 (with MET/CAL version 10.6.0) (.iso)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.2.0 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You may upgrade from version 3.0.0, 3.1.0, or 3.1.1 directly to version 3.2.0.Upgrading from version 3.x.x of MET/TEAM will not require you to re-request your licenses.Upgrading...

    Artigo
  • Update: MET/CONNECT version 1.1.0 (with MET/CAL version 10.1.0)

    Update: MET/CONNECT version 1.1.0 (with MET/CAL version 10.1.0) (.zip)Documents:MET/CAL 10.1.0 readme (.pdf)MET/CONNECT 1.1.0 Installation Guide (.pdf)MET/CONNECT 1.1.0 readme (.pdf)Review to our Quick Installation Guide on the Fluke Calibration Support Knowledge Base.Current MET/CONNECT Customers: What you need to know prior to updatingThe MET/CONNECT version 1.1.0 and MET/CAL version 10.1.0 release is an update to previous MET/CONNECT and MET/CAL software. This update includes bug fixes and minor...

    Artigo
  • Fluke 700HPPK/700HPM Recall

    Dear Customer, Thank you for registering your product(s) as part of our product safety recall of your Fluke 700HPPK/700HPM. We will soon be sending you a cable replacement to correct your Recalled Cable(s). A Fluke representative may contact you shortly if more information is needed. Please accept our most sincere apologies for any inconvenience caused by this action and should you have any questions, please do not hesitate to contact us. https://www.fluke.com/en-us/support/technical-support

    Artigo
  • Release: MET/TEAM version 3.1.0 (with MET/CAL version 10.5.0)

    Release: MET/TEAM version 3.1.0 (with MET/CAL version 10.5.0) (.iso)Documents:MET/TEAM 3.1.0 Readme (.pdf)MET/CAL 10.5.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)Update Instructions for MET/TEAM 3.1.0 and MET/CAL 10.5.0 (.pdf)This update is not for MET/CONNECT Customers. The MET/CONNECT version of this release is available here.Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.0 and MET/CAL version 10.5.0 release is a a major update to MET/TEAM and...

    Artigo
  • Release: MET/TEAM version 3.3.0 (with MET/CAL version 11.0.0)

    Release: MET/TEAM version 3.3.0 (with MET/CAL version 11.0.0) (.iso)Documents:MET/TEAM 3.3.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)MET/CAL 11.0.0 Read Me (.pdf)Updating to METTEAM 3.3.0 and METCAL 11.0.0 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.3.0 release is a minor update to MET/TEAM software. The MET/CAL version 11.0.0 release is a major update to MET/CAL software. This update includes new features, improvements, bug fixes, and minor...

    Artigo
  • RPM4 v1.01I Embedded Software

    RPM4 v1.01I Embedded Software (.bin)TITLEVERUSE WITHNOT FOR USE WITHRPM4™1.01I2019.04.28RPM4Note: If you have a special RPM4model use these links:RPM4-AD™RPM4-AF™RPM4-E-DWT A70M/A7M-AF™RPM4-E-DWT™Please contact our Calibration and Repair department at 602.773.4782 if you recently upgraded to version 1.01f or plan to upgrade from 1.01f to another version. The upgrade path from 1.01f may cause a potentially significant metrological error.Instructions:Download the file.Run Winflash and select...

    Artigo
  • Release: MET/CONNECT version 1.0.0 (with MET/CAL version 10.0.0)

    Release: MET/CONNECT version 1.0.0 (with MET/CAL version 10.0.0) (.zip)Documents:MET/CONNECT 1.0.0 Installation Guide (.pdf)MET/CONNECT 1.0.0 readme (.pdf)MET/CAL 10.0.0 readme (.pdf)Review our Quick Installation Guide on the Fluke Calibration Support Knowledge Base.New MET/CONNECT Customers or Current MET/TEAM or METBASE customersThis download is the 60-day trial version. Use the MET/CONNECT Server Installer to perform a new installation. This installer is included in the download link above and...

    Artigo
  • PPCK+ v1.00m Embedded Software

    PPCK+ v1.00m Embedded Software (.bin)TITLEVERUSE WITHPPCK+™1.00m2005.01.05PPCK+Instructions:Download the file.Run Winflash and select the file downloaded as the file to write to the product.Make sure the correct COM port of the product is connected to a RS232 port on the host PC. Use a null modem cable to COM2 port of PG7000 Piston Gauge. Use a standard RS232 cable to COM1 port of PPC, PPC, RPM and molbox.If your product has an model number ending in "-AF", it requires specific "-AF" embedded software.The...

    Artigo
  • RPTLoad Free Utility

    RPTLoad Free Utility (.exe)TITLEVERUSE WITHRPTLoad™ Free Utility1.04cAll products with quartz crystal based RPTs or Q-RPTsInstructions:Download and run the file. The installation program will prompt you through the process.DescriptionThe RPTLoad program is designed to transfer RPT coefficients to and from DHI products. In addition to updating coefficients, RPTLoad can also be used to configure RPM1 reference pressure monitors.Updates Include:Ver 1.04c (03 OCT 20)FIX: Corrected support of BG TYPE...

    Artigo
  • Crystal Reports 2020

    Crystal Reports 2020 (.exe)For the product key to use with your Crystal Reports Editor installation for MET/TEAM, contact softwaresupport@flukecal.com. Include a screen capture of your MET/TEAM Help>About screen. Instructions are here: https://my.fluke.com/en-us/article/KA-03961.This is the Crystal Reports to be used with MET/TEAM software (not MET/BASE) for editing Reports. Service Pack 2 Patch 5If you are currently using Crystal Reports Editor 2013, you should:Uninstall Crystal Reports 2013Reboot...

    Artigo
  • Crystal Reports 2013

    Crystal Reports 2013 (.iso)For the product key to use with your Crystal Reports Editor installation for MET/TEAM, contact softwaresupport@flukecal.com. Include the version you are using in your email.This is the Crystal Reports to be used with MET/TEAM software (not MET/BASE).Special instructionsClick on the link to download the software.MDS check sum:395a1705f0c23770ea5514580313bc4

    Artigo
  • Update: MET/TEAM version 2.3.0 (with MET/CAL version 9.2.0)

    Update: MET/TEAM version 2.3.0 (with MET/CAL version 9.2.0) (.iso)Documents:MET/CAL 9.2.0 Readme (.pdf)MET/TEAM 2.3.0 Readme (.pdf)MET/TEAM version 2.3.0 and MET/CAL version 9.2.0Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 2.3.0 and MET/CAL version 9.2.0 release is a security and stability update to previous MET/TEAM and MET/CAL software. This update includes security improvements, bug fixes, and minor updates.Upgrading from any previous version of MET/TEAM...

    Artigo
  • 1594A/1595A Firmware update version 1.22

    1594A/1595A Firmware update version 1.22 (.ud)Title: 1594A & 1595AVer: 1.22/1.02Use with: All 1594A & 1595ADate Modified: 2/20/2014Description of the change:  It was recently determined that when a customer selects the “Restore Factory Default” button in the Config Menu, the resistor calibration values are reset to the default values without requiring a password or notification to the customer that the values are being reset. Engineering has investigated this issue and the instrument firmware...

    Artigo
  • COMPASS Example Set Up Database

    COMPASS Example Set Up Database (.mdb)About COMPASS ExamplesCOMPASS examples are existing setups that are used as a guide to help add a new device to COMPASS.  There are 2 types of examples: those that appear directly in the DUT and/or Support Device Editors and those that do not.  Only a few examples are visible in the device editors.  This is in an attempt to minimize the confusion between various COMPASS setups.  The majority of the COMPASS examples are not directly visible to the user. ...

    Artigo
  • COMPASS for Pressure Calibration Software Download/Upgrade

    COMPASS for Pressure Basic (.exe)Additional Downloads:COMPASS for Pressure Basic, Demo (.exe)COMPASS for Pressure Basic, Upgrade (.exe)COMPASS for Pressure Enhanced (.exe)COMPASS for Pressure Enhanced, Demo (.exe)COMPASS for Pressure Enhanced, Upgrade (.exe)TITLEVERUSE WITHDOCUMENTSCOMPASS®for Pressure™5.2.102024.05.21FPG8601, PG7000, PPC2, PPC2+, PPC2 AF, PPC3, PPC4, PPCH, PPCK, PPCK+, RPM3, RPM4, 7050, 7052, 7250, 7252, 7350, 7615, 7750, 7010, 7215, 2465, 2456, 2271A, 6270A, 8270A, 8370A,Third...

    Artigo
  • MET/TEAM version 2.2 (with MET/CAL version 9.1)

    MET/TEAM version 2.2 (with MET/CAL version 9.1) (.iso)Documents:MET/CAL 9.1.0 Readme (.pdf)MET/TEAM 2.2.0 Readme (.pdf)Updating to MET/TEAM 2.2 and MET/CAL 9.1 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThere has been a major change to the MET/TEAM database which means updating to version 2.2 is a multistep process that could take from 8 to 24 hours depending on your database, server configuration, and network environment.There has been a major change to MET/CAL regarding...

    Artigo
  • MET/TEAM® v3.3.0 and MET/CAL® v11.0.0 Software Trial

    Release: MET/TEAM version 3.1.1 (with MET/CAL version 10.5.0) (.iso)Documents:MET/CAL 10.5.0 Readme (.pdf)MET/TEAM Installation Guide (.pdf)MET/TEAM 3.1.1 Readme (.pdf)Update Instructions for MET/TEAM 3.1.1 and MET/CAL 10.5.0 (.pdf)This update is not for MET/CONNECT Customers. Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.1.1 release is a a minor update to MET/TEAM software. This update includes new features, improvements, bug fixes, and minor updates.You...

    Artigo
  • Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0)

    Release: MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.iso)Documents:MET/TEAM version 3.0.0 (with MET/CAL version 10.2.0) (.pdf)MET/TEAM 3.0.0 ReadMe (.pdf)MET/CAL 10.2.0 ReadMe (.pdf)MET/TEAM Installation Guide (Updated for version 3.0) (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 3.0.0 and MET/CAL version 10.2.0 release is a a major update to MET/TEAM and MET/CAL software. This update includes new features, improvements, bug fixes, and minor...

    Artigo
  • FPGTools PC Based Software

    FPGTools PC Based Software (.exe)File size is 171.33 mb.TITLEVERUSE WITHFPGTools™3.03f2010.06.03FPG8601DescriptionFPGTools is PC based software.SummaryThis application is the PC interface to the FPG8601 and the VLPC. Features are included to log data from the FPG and up to 5 DUTs, run test sequences, and perform all necessary routine procedures required by the FPG. This application cannot be used without an FPG8601 and a functioning RS232 port on the host computer.Instructions:Download and run...

    Artigo
  • MET/TEAM version 2.1 with Update 1 (with MET/CAL version 9.0 with Update 1)

    MET/TEAM version 2.1 with Update 1 (with MET/CAL version 9.0 with Update 1) (.iso)Documents:MET_TEAM_2_1_2_readme (.pdf)METCAL_9.0.0_ReadMe (.pdf)Please read the MET/TEAM Readme file before installing the upgrade.Please note that upgrading from any previous version of MET/TEAM will require you to re-request all of your licenses via email once the upgrade is complete! You must provide your original product codes and gold number(699XXXX) as two separate product code entry lines.If you are upgrading...

    Artigo
  • MET/TEMP II Software Download

    MET/TEMP II Software Download (.exe)TITLEVERLinksMET/TEMP II5.2Product PageDescriptionWhen downloaded, this file can be run to install MET/TEMP II. There is no free demo/trial version of 5.2. In order to install MET/TEMP II v5.2, you must purchase the software and obtain a serial number. The installation process prompts you to enter the serial number. Version 5.2 does not accept serial numbers from previous versions of MET/TEMP II. The serial number will be located on a sticker on the CD pouch....

    Artigo
  • Update: MET/TEAM version 2.2.1 (with MET/CAL version 9.1.1)

    Update: MET/TEAM version 2.2.1 (with MET/CAL version 9.1.1) (.iso)Documents:MET/CAL 9.1.1 Readme (.pdf)MET/TEAM 2.2.1 Readme (.pdf)Updating to METTEAM 2.2.1 and METCAL 9.1.1 (.pdf)Current MET/TEAM Customers: What you need to know prior to updatingThe MET/TEAM version 2.2.1 and MET/CAL version 9.1.1 release is a stability update to previous MET/TEAM and MET/CAL software. This update includes bug fixes and minor updates.Upgrading from any previous version of MET/TEAM will require you to re-request...

    Artigo
  • WinFlash Free Utility

    WinFlash Free Utility (.exe)Additional Downloads: WinFlash64™ 2.20 (64bit OS) (.exe)PC BasedFree Utilities - WinFlash™TITLEVERUSE WITHWinFlash™2.202011.10.05PPC2+, PPC3, PPC4, PPCH, PPCHG, PPCK+, MFC-CB, molbox1, molbox1+, molbox RFM, PG7000, RPM3, RPM4, RPM4-AD, RPM4-AF, RPM4-E-DWTWinFlash64™(64bit OS)2.202011.10.05PPC2+, PPC3, PPC4, PPCH, PPCHG, PPCK+, MFC-CB, molbox1, molbox1+, molbox RFM, PG7000, RPM3, RPM4, RPM4-AD, RPM4-AF, RPM4-E-DWTDescriptionFirmware upgrade utility. This program...

    Artigo
  • Replacing PACE 5000 with the 6270A Modular Pressure Controller/Calibrator

    This application note summarizes some of the benefits of upgrading to the 6270A, as well as detailing the steps for configuring and installing the 6270A as a replacement to the PACE 5000.

    Artigo
  • Modularity in pressure calibration systems

    Read this free app note to learn the benefits of modular pressure calibration systems over monolithic & learn how to assess what modular system fits you best.

    Artigo
  • Temperature baths increase stability in medical device manufacturing and tempering process

    For medical device manufacturing, especially with nitinol, learn how to improve stability and uniformity by using a high-temperature salt calibration bath.

    Artigo
  • Three Expert Tips for Automating Your Lab with Calibration Automation Software

    Get tips for automating your lab with calibration automation software. Get more done more accurately with less experienced staff who learn as they go.

    Artigo
Converse com oAssistente da Fluke
Limpar conversa