Fluke CNX t3000 K-Type Wireless Temperature Module
Fitur utama
The CNX™ t3000 K-Type Wireless Temperature Module provides:
- Temperature measurements from -200 °C to 1372 °C
- ± 0.5% accuracy
- Memory recording up to 65,000 readings
- Backlit LCD display
- IP42 with thrmocouple installed
The CNX™ wireless test tools can track up to 10 measurement modules simultaneously, with results sent to a PC for detailed analysis.
Ikhtisar Produk: Fluke CNX t3000 K-Type Wireless Temperature Module
The CNX t3000 K-Type Wireless Temperature Module is part of the Fluke team of wireless troubleshooting tools.
Connect the CNX t3000 Wireless Temperature Module to your test point, and view the results up to 20 meters away on the CNX 3000 Wireless Multimeter. You’ll save time, with less run-around collecting multiple measurements. Plus, no more writing down data as the CNX 3000 captures up to 65,000 sets of time stamped min/max/avg readings. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.
Spesifikasi: Fluke CNX t3000 K-Type Wireless Temperature Module
General Specifications | |
Range | K-Type: -200 °C to 1372 °C |
Resolution | 0.1 °C |
Accuracy | ±[0.5 % + 0.3 °C] counts |
Input terminals | K-Type mini |
LCD w/backlight | 3 . digits |
Log rate/interval | 1 sec minimum/adjustable by PC |
Battery type | 2 AA, NEDA 15 A, IEC LR6 |
Battery life | 400 hours |
Memory | Record up to 65,000 readings |
Unbound listen interval | 5 seconds |
RF communications | 2.4 GHZ ISM Band |
RF communication range | 20 Meters |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Temperature scale | ITS-90 |
Operating humidity | 90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C |
EMC | EN 61326-1:2006 |
Safety compliance | CAT I per IEC/EN 61010-1:2010, EN/IEC 61010-2-030:2010 |
Pollution degree | 2 |
Temperature coefficient | 0.01 % of reading +0.03 °C per °C |
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS |
Ingress Protection (IP) rating | IP42 with thermocouple installed |
Size (HxWxD) | 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | .22 kg (8 oz) |
Manual + Sumber: Fluke CNX t3000 K-Type Wireless Temperature Module
- CNX 3000 | Manual Pengguna
- CNX 3000 | Tambahan Manual Pengguna
- CNX 3000 | Manual Kalibrasi
- CNX 3000 | Pernyataan ketidakstabilan memori
- CNX 3000 | Lembar Petunjuk
- CNX 3000 | Panduan Referensi Cepat
- CNX a3000 | Panduan Referensi Cepat
- CNX a3000 | Lembar Keamanan
- CNX i3000 | Panduan Referensi Cepat
- CNX i3000 | Manual Kalibrasi
- CNX i3000 | Tambahan Manual Kalibrasi
- CNX i3000 | Lembar Keamanan
- CNX t3000 | Lembar Keamanan
- CNX t3000 | Manual Kalibrasi
- CNX t3000 | Panduan Referensi Cepat
- CNX v3000 | Panduan Referensi Cepat
- CNX v3000 | Manual Kalibrasi
- CNX v3000 | Lembar Keamanan
- CNX v3000, CNX t3000, CNX i3000, CNX a3000 | Pernyataan ketidakstabilan memori
- Radio Frequency Data Class A | Lembar Petunjuk
- v3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC | Pernyataan ketidakstabilan memori