Bahasa

Fluke 17Bplus Digital Multimeter

  • Fluke 17Bplus Digital Multimeter 1
  • Fluke 17Bplus Digital Multimeter 2
  • Fluke 17Bplus Digital Multimeter 3
Tidak Diproduksi Lagi

Fitur utama

  • 600 V Cat III safety rating
  • AC/DC voltage measurement up to 1000V
  • AC/DC current measurement up to 10A
  • Measures voltage, resistance, continuity, capacitance
  • Frequency and temperature measurement
  • Large easy-to-read display with bright white backlight
Produk ini dihentikan atau diklasifikasikan ulang

Ikhtisar Produk: Fluke 17Bplus Digital Multimeter

Fluke quality is always within your reach

Experience the precision, durability, and safety of a professional-grade test tool with the Fluke 17B+ Digital Multimeter. With the Fluke 17B+, you'll have a rugged, portable tool that's designed to be used with one hand, even while wearing gloves. It provides all the essential features you need in a digital multimeter, from AC/DC voltage and current measurements up to 1000V and 10A, to comprehensive capabilities including resistance, capacitance, and frequency checks. It also comes standard with a type K thermocouple so you can measure the temperature of things like your refrigeration systems, heat exchangers, and line sets. The 17B+ also supports relative measurements which allows you to zero out a source reading so you can easily measure changes in things like voltage drop or temperature making it ideal for identifying and diagnosing issues. 

The CAT III 600V safety rating provides peace of mind for everything from routine checks on electrical equipment and appliances, to checking voltage levels at power outlets or switches, to diagnosing issues with circuits. If you’re looking to build out your toolkit as a DIY enthusiast or early career electrician, look no further than the Fluke 17B+ Digital Multimeter, a reliable and versatile tool that provides the essential features you need.

Spesifikasi: Fluke 17Bplus Digital Multimeter

Accuracy Specifications

Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0% to 75%. Accuracy specifications take the form of: ±(% of Reading + Number of Least Significant Digits).

FunctionRangeResolutionAccuracy
AC volts
(40 Hz to 500Hz)1
4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
1.0% + 3
DC volts4.000 V
40.00 V
400.0 V
1000 V
0.001 V
0.01 V
0.1 V
1 V
0.5% + 3
AC millivolts400.0 mV0.1 mV3.0% + 3
DC millivolts400.0 mV0.1 mV1.0% + 10
Diode test22.000 V0.001 V10%
Resistance
(Ohms)
400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
0.5% + 3
0.5% + 2
0.5% + 2
0.5% + 2
0.5% + 2
1.5% + 3
Capacitance340.00 nF
400.0 nF
4.000 μF
40.00 μF
400.0 μF
1000 μF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.1 μF
1 μF
2% + 5
2% + 5
5% + 5
5% + 5
5% + 5
5% + 5
Frequency1 Hz
(10 Hz – 100 kHz)
50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
0.1% + 3
Duty Cycle11% to 99%0.1%1% typical 4
AC current μA
(40 Hz to 400 Hz)
400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
AC current mA
(40 Hz to 400 Hz)
40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
AC current A
(40 Hz to 400 Hz)
4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
DC current μA400.0 μA
4000 μA
0.1 μA
1 μA
1.5% + 3
DC current mA40.00 mA
400.0 mA
0.01 mA
0.1 mA
1.5% + 3
DC current A4.000 A
10.00 A
0.001 A
0.01 A
1.5% + 3
Temperature50 °C- 400 °C
0 °C- 50 °C
-55 °C- 0 °C
0.1C2% ±1 °C
±2 °C
9% ±2 °C
Backlight--Yes
1All ac, Hz, and duty cycle are specified from 1% to 100% of range. Inputs below 1% of range are not specified.
2Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA.
3Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range).
4Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10% and 90%.
FunctionOverload protectionInput impedance (Nominal)Common mode rejection ratioNormal mode rejection ratio
AC volts1000 V 1>10 MΩ <100 pF>60 dB at dc,
50 Hz or 60 Hz
-
AC millivolts400 mV>1MΩ, <100 pF>80 dB at 50 Hz or 60 Hz-
DC volts1000 V 1>10 MΩ <100 pF>100 dB at dc,
50 Hz or 60 Hz
>60 dB at 50 Hz or 60 Hz
DC millivolts400 mV>1MΩ, <100 pF>80 dB at 50 Hz or 60 Hz-
1 106 V Hz Max
General specifications
Maximum voltage between any terminal and earth ground1000 V
Display (LCD)4000 counts, updates 3/sec
Battery type2 AA, NEDA 15A, IEC LR6
Battery life500 hours minimum
Temperature
Operating0 °C to 40 °C
Storage-30 °C to 60 °C
Relative humidity
Operating humidityNon-condensing (<10°C)
≤90% RH at 10 °C to 30 °C
≤75% RH at 30 °C to 40 °C
40 MΩ range
≤80% RH at 10 °C to 30 °C
≤70% RH at 30 °C to 40 °C
Altitude
Operating2000 m
Storage12,000 m
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Fuse protection for current inputs440 mA, 1000 V Fast Fuse, Fluke specified part only.
11A, 1000V Fast Fuse, Fluke specified part only.
Size (H x W x L)183 x 91 x 49.5 mm
Weight455 g
IP ratingIP 40
SafetyIEC 61010-1, IEC61010-2-030 CAT III 600 V, Pollution Degree 2
Electromagnetic compatibilityIEC 61326-1: Portable EMC Environment
Class A equipment (industrial broadcasting and communication equipment)1
1 This product meets requirements for industrial (Class A) electromagnetic wave equipment and seller or
user should take notice of it. This equipment is intended for use in business environments and is not to be
used in homes.