Bahasa

Fluke i310s Current Probe

  • Fluke i310s Current Probe

Fitur utama

  • Current Ranges: 30 A and 300 A ACRMS or ±45 A and 450 A DC
  • Measuring Ranges: ±45 A and 450 A dc
  • Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
  • Resolution: ±50 mA (40 A) to ±100 mA (400 A)
  • Load Impedance: > 10 k Ohms and £ 100 pF
  • Frequency Range (small signal): DC to 20 kHz (- 3 dB)
  • Phase Shift below 1 kHz, < 2 degrees
  • Temperature Coefficient: ±0.1% of reading / °C
  • Power Supply: 9 V Alkaline

Ikhtisar Produk: Fluke i310s Current Probe

The i310s current probe is based on Hall Effect technology for use in measurement of both DC and AC current. The i310s may be used in conjunction with oscilloscopes and other suitable recording instruments for accurate non-intrusive current measurement.

Spesifikasi: Fluke i310s Current Probe

Electrical Characteristics
Current ranges30 A and 300 A AC rms or ±45 A and 450 A DC
Measuring ranges±45 A and 450 A DC
AC rms or DC±45 A and 450 A
Inrush current600A AC rms MAX
Output sensitivity10 mV/A (30 A)
1 mV/A (300 A)
Accuracy (at +23°C)(30 A range)±1% of reading ±50 mA
(300 A range)±1% of reading ±300 mA
Bandwidth to meet accuracy specification1 kHz
Phase shift below 1 kHz< 2 degrees
Resolution±50 mA (30 A)
±100 mA (300 A)
Load impedance> 10 k Ohms and ≤100 pF
Conductor position sensitivity±1.5% relative to centre reading
Frequency range (small signal)DC to 20 kHz (-3 dB)
Phase shift below 1 kHz< 2°
Temperature coefficient±0.1% of reading / °C
Power supply9 V Alkaline, MN1604/PP3
Battery life30 Hours, low battery indicator
Working voltage (see Safety Standards section)300 V AC rms or DC
General Characteristics
Maximum conductor size19 mm diameter
Output connectionSafety BNC connector
Supplied with safety 4mm adaptor
Output zeroManual adjust via thumbwheel
Cable length2 metres
Operating temperature range-10 to +50°C
Storage temperature range (with battery removed)-20 to +85°C
Operating humidity15% to 85% (non-condensing)
Weight250 g
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2- 032: CAT III 300V
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
EMC CompatibilityIEC 61326-1: Portable Electromagnetic Environment

Model: Fluke i310s Current Probe

i310s

AC/DC CURRENT CLAMP

Belilah