Fluke 6500-2 Portable Appliance Tester with TruTest Data Management Software Kit
Key features
- 6500-2 Portable Appliance Tester
- TruTest Data Management Software"
Product overview: Fluke 6500-2 Portable Appliance Tester with TruTest Data Management Software Kit
Fluke 6500-2 Portable Appliance Tester
The Fluke 6500-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day. The 6500-2 is designed to enable you to work faster without compromising test results.
- Dedicated key for each test for ‘one-touch’ testing
- Complies with the new standards EN 50678 and EN 50699
- Pre-set pass/fail levels to save time
- Large backlit display for easy reading
- Single mains socket for appliance connection
- Separate IEC socket for easy mains/extension lead testing
- Detachable test leads for quick field replacement
- Integral carrying handle
- USB port for data transfer
- Integral QWERTY keyboard for rapid data entry
- Additional USB memory capability for back-up data storage and transfer to PC
- Large backlit graphics display
- Pre-set, auto-test sequences for user convenience
- Integral site, location and description codes for faster data processing
- Memory review facility for more on-site control
- USB port for data transfer
Fluke TruTest Data Management Software
Fluke TruTest Software is designed to eliminate the hassle associated with traditional electrical system data management and reporting. Whether you are testing fixed wire installations, or appliances in an office, verifying repairs in a workshop, or performing annual inspections proper data management is critical for producing easy-to-understand reports for clients. Compatible with a growing list of Fluke and Beha-Amprobe test and measurement devices TruTest Software allows you to quickly and easily import measurement results directly from your test instruments, manage files transferred from instruments, or manually enter data as needed.
What's in the box:
- Fluke 6500-2 Portable Appliance Tester
- Quick reference guide
- Hard carrying case
- Test lead
- Test probe
- Crocodile clip
- Mains cord
- USB stick
- USB cable
- TruTest Data Management Software
Specifications: Fluke 6500-2 Portable Appliance Tester with TruTest Data Management Software Kit
Specifications | ||
Test specifications | The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH. | |
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. | ||
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2. | ||
Power-on test | The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. | |
Display range | 90 V to 264 V | |
Accuracy at 50 Hz | ±(2% + 3 counts) | |
Resolution | 0.1 V | |
Input impedance | > 1 MΩ // 2.2 nF | |
Maximum input mains voltage | 264 V | |
Earth bond test (Rpe) | Display Range | 0 to 19.99 Ω |
Accuracy (after bond test zeroing) | ±(5% + 4 counts) | |
Resolution | 0.01 Ω | |
Test current | 200 mA AC -0% +40% into 1.99 Ω 10 A AC ±20% into 25 mΩ at 230 V | |
Open circuit voltage | > 4 V AC, < 24 V AC | |
Bond test zeroing | can subtract up to 1.99 Ω | |
Insulation test (Riso) | Display range | 0 to 299 MΩ |
Accuracy | ±(5% + 2 counts) from 0.1 to 300 MΩ | |
Resolution | 0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199.9 MΩ) 1 MΩ (200 to 299 MΩ) | |
Test voltage | 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0% +25% at 250 kΩ load | |
Test current | > 1 mA at 500 kΩ load, < 15 mA at 0 Ω | |
Auto discharge time | < 0.5 s for 1 μF | |
Max. capacitive load | Operational up to 1 μF | |
Touch current test | Display range | 0 to 1.99 mA AC |
Accuracy | ±(4% + 2 counts) | |
Resolution | 0.01 mA | |
Internal resistance (via probe) | 2 kΩ | |
Measuring method | Probe* | |
Substitute leakage current test | Display range | 0 to 19.99 mA AC |
Accuracy | ±(2.5% + 3 counts) | |
Resolution | 0.01 mA | |
Test Voltage | 100 V AC ±20% | |
Load/leakage test: load current | Display range | 0 A to 13 A |
Accuracy | ±(4% + 2 counts) | |
Resolution | 0.1 A* | |
Load/leakage test: load power | Display range 230 V Mains | 0.0 VA to 3.2 kVA |
Accuracy | ±(5% + 3 counts) | |
Resolution | 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)* | |
Load/leakage test: leakage current | Display range | 0 to 19.99 mA |
Accuracy | ±(4% + 4 counts) | |
Resolution | 0.01 mA* | |
PELV test | Accuracy at 50 Hz | ±(2% + 3 counts) |
Overload protection | 300 V rms | |
Warning threshold | 25 V rms | |
RCD test: trip current | Operational error | ±10% |
Nominal | 30 mA | |
Accuracy | ±5% | |
RCD test: trip time | Standard requirement | 61557 Part 6; tolerance of rated test current 0% to +10% |
Operational error | ±10% | |
RCD type | AC general-purpose 30 mA | |
Display range | 310 ms | |
Resolution | 0.1 ms | |
Accuracy | 3 ms | |
Trip time limit at 100% (30 mA) | 300 ms | |
Trip time limit at 500% (150 mA) | 40 ms | |
*The appliance under test is energized at mains potential. |
Environmental specifications | |
Operating temperature | 0 to 40 °C |
Relative humidity | Non condensing <10 °C |
95% from 10 to 30 °C | |
75% from 30 to 40 °C |
Safety specifications | |
Safety rating | Complies with EN61010-1 3rd edition |
CAT II, 300 V, pol 2 |
Mechanical and general specifications | ||
Size (L x W x H) | 200 x 275 x 114 mm | |
Weight | 3.13 kg | |
Power supply | 230 V +10% -15%, 50 Hz ±2 Hz or (6500-2 only: 110V +10% -15%,50 Hz ±2 Hz) | |
Power consumption (tester) | 13 W typical (idle) 60 W max. during 25A Bond test | |
Storage | Temperature | -10 to 60 °C |
Corrosion | 70 °C @ 95% RH for 5 days max. | |
Operating altitude | 0 up to 2000 m | |
Sealing | IP-40 (enclosure), IP-20 (connectors) | |
EMC | Complies with EN61326-1, portable | |
EMI Immunity | 3 V/m |
Function | Demo | Lite | Advanced |
Database structure (Local standalone or server based) | Local | Local | Local |
Portable Appliance Tester (PAT) module | • | • | • |
Portable Appliance Testers supported | Fluke 6500, Fluke 6500-2, Beha-Amprobe GT-600, Beha-Amprobe GT-650, Beha-Amprobe GT-800, Beha-Amprobe GT-900 | ||
Maximum addable clients | 1 | 2 | Unlimited |
Maximum addable sites/client | 2 | 5 | Unlimited |
Maximum addable locations/client | 5 | 50 | Unlimited |
Maximum addable appliances/client | 20 | 1000 | Unlimited |
Installation Testers (INST) module | • | • | • |
Installation Testers supported | Fluke 1653, Fluke 1653B, Fluke 1654B, Fluke 1662, Fluke 1663, Fluke 1664 FC, Beha-Amprobe ProInstall-100, Beha-Amprobe ProInstall-200 | ||
Maximum addable clients | 1 | 2 | Unlimited |
Maximum addable sites/client | 2 | 5 | Unlimited |
Maximum addable locations/client | 5 | 25 | Unlimited |
Maximum addable appliances/client | 50 | 200 | Unlimited |
Include demo database | • | • | • |
Create clients | • | • | • |
Rename clients | • | • | |
Delete clients | • | • | • |
Create nodes | • | • | • |
Move nodes | • | • | • |
Rename nodes | • | • | |
Delete nodes | • | • | • |
Edit client information | • | • | |
Edit site information | • | • | |
Edit location information | • | • | |
Edit appliance information | • | • | |
Edit test information | • | • | |
Add test step | • | • | |
Delete test step | • | • | |
Edit test step | • | • | |
Add remarks | • | • | |
Add attachment (file) to remark | • | ||
Edit remark | • | • | |
Delete remark | • | • | |
Read data from instrument | • | • | • |
Read data from file | • | • | • |
Read data conflict management | • | • | • |
Read data assign tree structure | • | • | • |
Load data to instrument | *Compatible tool required | ||
Use search | • | • | • |
Show reports | With watermark | • | • |
Show certificates | With watermark | • | • |
Save (PDF, XML,…) /Print reports | • | • | |
Save (PDF, XML,…)/Print certificates | • | • | |
Add engineers | Demo engineer | • | • |
Edit engineers | • | • | |
Delete engineers | • | • | |
Print engineers | • | • | |
Add test instruments | Demo instrument | • | • |
Edit test instruments | • | • | |
Delete test instruments | • | • | |
Print test instruments | • | • | |
Edit my company info | Demo company | • | • |
Edit company logo | Demo logo | • | |
Edit certification logo | Demo logo | • | |
View Auto Test Codes | • | • | • |
Select favorites Auto Test Codes | • | • | |
Print favorites Auto Test Codes | • | • | |
Print All Auto Test Codes | • | • | |
Create customized Auto Test Codes | • | ||
Edit customized Auto Test Codes | • | ||
Copy customized Auto Test Codes | • | ||
Delete customized Auto Test Codes | • | ||
Print Customized Auto Test Codes | • | ||
Create backup | • | • | |
Restore backup | • | • | |
Maximum users | 1 Demo user | 2 | Unlimited |
Add users | • | • | |
Edit users | • | • | |
User roles | • | • | |
Edit user roles | • | • | |
Print users list | • | • | |
Edit limits | • | • | |
Available languages | EN, DE, FR, IT, NL | ||
Supported Installation certificates | DIN VDE 0701-0702, ÖVE/ÖNORM E 8701, SNR 462638, NEN3140, International template | ||
Change language | • | • | • |
Change country | • | • | • |
Change report language | • | ||
Expire duration | 60 days (calculated from installation date) | Unlimited | |
Free updates | 5 years (calculated from enter serial code date) | ||
Expiration popup notice | Daily | Every 30 days after 5 year free update period | |
Activation date with days left until expiration | • | • | • |
System requirements
Type | Requirement |
Operating System |
|
System Memory | Minimum 4 GB RAM (64-bit) or 2 GB RAM (32-bit) |
Hard disk space | Minimum 2 GB available hard disk space |
Display resolution | Minimum screen resolution 1366 x 768 |
Communication interfaces | USB |
Models: Fluke 6500-2 Portable Appliance Tester with TruTest Data Management Software Kit
Fluke 6500-2 Portable Appliance Tester with TruTest Data Management Software Kit
Includes:
- Fluke 6500-2 Portable Appliance Tester
- Quick reference guide
- Hard carrying case
- Test lead
- Test probe
- Crocodile clip
- Mains cord
- USB stick
- USB cable