Fluke ii900 Industrial Acoustic Imager
Fluke ii900 Industrial Acoustic Imager is rated out of 5 by 6.
Key features
- NEW: Leak volume and cost indication on the go
- NEW: CO2 emission reporting
- Improve energy efficiency. Do more with the same air compressors and delay the capital expense of purchasing an additional compressor
- Lower utility and downtime costs
- Reduce time and costs to detect leaks
- Improve production process and pneumatic equipment reliability
Product overview: Fluke ii900 Industrial Acoustic Imager
What's in the box:
- Fluke ii900 Industrial Acoustic Imager
- AC power supply and battery pack charger (including universal AC adapters)
- Two rugged lithium ion smart battery packs
- USB cable
- Rugged, hard carrying case
- Adjustable hand strap and neck strap
Specifications: Fluke ii900 Industrial Acoustic Imager
Sensors | |
---|---|
# of microphones | 64 digital MEMS microphones |
Frequency band | 2 kHz to 52 kHz |
Sound pressure sensitivity | Detects a 0.005 CFM leak at 100PSI from up to 32.8 feet (Detects a 2.5 cm3/sec leak at 7 bar from up to 10 meters) |
Operation distance range | 0.5 to > 70 meters (1.6 to > 164 feet)* |
Field of View | 63 ° ± 5 ° |
Nominal frame rate | 25 FPS |
*Depending on ambient conditions |
Built-in digital camera (visible light) | |
---|---|
Field of View (FOV) | 63 ° ± 5 ° |
Focus | Fixed lens |
Zoom | 3 x Digital Zoom |
Resolution | 1.2 MP |
Display | 7" LCD with backlight, under-sunlight readable |
---|---|
Resolution | 1280 x 800 (1,024,000 pixels) |
Touchscreen | Capacitive |
Acoustic Image | Yes, SoundMap™ image |
Image storage | |
---|---|
Storage capacity | 20GB (>5000 pictures / >999 videos) |
Image format | Blended visual and SoundMap™.JPG or .PNG |
Video format | Blended visual and SoundMap™.MP4 |
Video length | Up to 5 minutes |
Digital export | USB-C for data transfer |
Acoustic Measurements | |
---|---|
Sound pressure (typical) | 15.4 dB to 115.2 dB SPL (±1 dB) at 2 kHz 5.6 dB to 102.5 dB SPL (±2 dB) at 19 kHz 28.4 dB to 131.1 dB SPL (±1 dB) at 35 kHz 41.8 dB to 133.1 dB SPL (±3 dB) at 52 kHz |
Auto max/min dB gain | Auto or manual, user selectable |
Frequency band selection | User selectable through user-made presets or manual entry |
Classification and quantification | LeakQ™ Leak size and cost estimation |
Software | |
---|---|
Ease of use | Intuitive user interface |
Trend graphs | Frequency and dB scale |
Spot markers | dB level reading at center point of the image |
Asset ID | QR code based asset ID identification |
Asset Inspection Status: | 'As left', 'As found' ; 'Undetermined' |
Photo notes | Up to 4 photos notes for reference |
Source | Show single or multiple sources |
Profile | Preset capture profiles |
Annotation: | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure; |
Other | Operating conditions; Weather notes |
Leak values | Leak costs; Leak volume; LeakQ™ scale |
Battery | |
---|---|
Batteries (field-replaceable, rechargeable) | Rechargeable Li-ion |
Battery life | 6 hours (product includes spare battery) |
Battery charging time | 3 hours |
Battery charging system | External charger |
General Specifications | |
---|---|
Standard palettes | 3: Grayscale, Ironbow, Blue-Red |
Operating Temperature | -10 °C to 45 °C (14 °F to 113 °F) |
Storage Temperature | -20 °C to 70 °C (-4 °F to 158 °F) Without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) |
Weight (battery included) | 1.8 kg (3.95 pounds) |
Ingress Protection (IP) | IP40 |
Warranty | 2 year |
Fluke Premium Care | Premium Care Standard** |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
RoHS compliant | Yes |
** Subject to regional availability |
Safety | |
---|---|
General Safety | IEC 61010-1 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication) |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Models: Fluke ii900 Industrial Acoustic Imager
FLK-ii900
Fluke ii900 Sonic Industrial Imager
Includes:
- Imager
- AC power supply and battery pack charger (including universal AC adapters)
- Two rugged lithium ion smart battery packs
- USB cable
- Rugged, hard carrying case
- Adjustable hand strap and neck strap
How small of a vacuum leak can the unit detect? The specs do not list this.
There are many factors that play into leak measurement so there are no specifications for the size of leaks that are able to be detected by the Fluke ii900 Industrial Acoustic Imager. For instance, pressure in the system, sound in the area, and how far away effect leak measurement.
Date published: 2024-07-12
Is the ii900 or the ii910 Intrinsically safe?
No, the Fluke ii900 and ii910 are not intrinsically safe.
Date published: 2024-07-26
Can the device be triggered remotely? Would like to use the imager in an area where it may not be safe during pressure testing.
The ii900 can not be triggered remotely.
Date published: 2024-03-28
Is the frequency of a leak in relation to the pressure differential, or is it a function of the size of the leak? In other words does the high pressure side dictate the frequency. Is there a lower pressure threshold for leak detection? 5 pascals?
Please contact Fluke's tech support team at tech.support@fluke.com or 800-443-5853.
Date published: 2024-06-06
ii900&ii910 , We want to know how to calculate the distance of the Leak Q function.
Please contact Fluke's tech support team at tech.support@fluke.com or 800-443-5853.
Date published: 2024-06-06
Can the Fluke ii900 be used in a more quite environment (e.g down day in plant room) to find refrigeration leaks, as these leaks can more quite or be microleaks making minimal sound, does this tool have the ability to find such leaks
The Fluke ii900 Industrial Acoustic Imager can be used in many environments and detects leaks in based on the frequency, rather than the size of the hole or make up of the gasses leaking. It can hear a leak between 2 kHz to 52 kHz in frequency.
Date published: 2023-10-03
Can this detect vacuum leaks, i.e. air being pulled into a system not just exiting out?
Yes, the Fluke ii900 Industrial Acoustic Imager can be used for vacuum leaks.
Date published: 2023-11-13
what is the maximum atmospheric pressure the ii900/910 can safely function?
The Fluke ii900 Industrial Acoustic Imager and Fluke ii910 Precision Acoustic Imager environmental parameters state they can be used from sea level up to an altitude of 2000 meters for operation, and sea level to 12,000 meters for storage.
Date published: 2023-09-12
Rated 5 out of 5 by srwilhelm from Incredible Tool This is an incredible tool for finding leaks. We used the ii910. It has also been used for finding partial electrical discharges on insulators.
Date published: 2022-10-26
Rated 5 out of 5 by Richard M from Simple to use and accurate! Visually shows you where an air leak is located, also gives you options to capture a photo and add notes with a easy to use touchscreen.
Date published: 2021-03-23
Rated 5 out of 5 by Anonymous from Time Saver! I have used the ii900 for 8 months now and it is absolutely amazing. This will find air leaks you cannot hear including in a loud environment. Storing photos of the leak and the information from the leak all on the tool. I upload the files to the computer and use flukes software to create a report and it even estimates the cost of the leak.
Date published: 2020-10-13
Manuals + resources: Fluke ii900 Industrial Acoustic Imager
- LeakQ™ / PDQ Mode™ Reporting Tool | Users manual
- ii900 / ii910 | Users manual
- ii900 / ii910 | Users manual supplement
- ii900 / ii910 | Safety sheet
- ii900 / ii910 | Statement of memory volatility
- ii900 / ii910 | Quick reference guide
- ii900 / ii910 | Quick reference guide supplement
- ii900 / ii910 | Product specification
- LeakQ™ / PDQ Mode™ Reporting Tool for ii900/ii910 Acoustic Imager | Quick reference guide