English

Fluke 117 Electrician's Multimeter plus insulated hand tools starter kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.32ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • F-117 Multimeter plus insulated hand tools starter kit
  • Heavy duty, high leverage diagonal cutter with power joint and precision cutting edges. 1000 V ac rated.
  • Fluke 117 Electrician's Multimeter

Key features

  • 117: Compact, true-rms electricians digital multimeter
  • 117: Integrated non-contact voltage detection keeps you safe
  • Insulated tools: certified to 1000 V AC, 1500 V DC
  • Insulated tools: ergonomic 5-piece set

Product overview: Fluke 117 Electrician's Multimeter plus insulated hand tools starter kit

This kit combines a general-purpose electrician’s digital multimeter with the most frequently used insulated screwdrivers, pliers and cutters.

Insulated hand tools includes:

  • Fluke 117 Electrician’s Multimeter
  • Slotted screwdrivers – three different handle lengths, each with a different blade width
  • Phillips screwdrivers – #1 and #2 tip sizes, with differing handle lengths
  • Long nose pliers with side cutter and gripping zones
  • Heavy-duty, high leverage diagonal cutter
  • Heavy-duty combination pliers
  • A roll-up pouch with hook-and-loop fasteners

Electrician’s multimeter

The Fluke 117 is a true-rms digital multimeter with integrated non-contact voltage detection. AutoVolts selects whether AC or DC voltage is being measured, while the LoZ function helps prevent false readings caused by ghost voltage.

The insulated hand tools are all made from hardened chromium-molybdenum-vanadium (CMV) steel. Each insulated hand tool is individually tested to 10,000 V and:

  • Certified to 1000 V AC
  • Certified to 1500 V DC

All backed with a limited lifetime warranty.

What's in the box:

  • 117 Electrician’s Multimeter
    • 4 mm silicone test lead set
    • Holster
  • Insulated hand tools starter kit:
    • Fluke 117 Electrician's Multimeter
    • ISLS3 Slotted Screwdriver 3/32, 3"
    • ISLS5 Slotted Screwdriver 5/32, 4"
    • ISLS8 Slotted Screwdriver 1/4, 5"
    • IPHS1 Phillips Screwdriver #1, 3"
    • IPHS2 Phillips Screwdriver #2, 4"
    • INLP8 Long Nose /w Side Cutter and Gripping Zones
    • INDC8 Heavy Duty High Leverage Diagonal Cutter
    • INCP8 Heavy Duty Linesman Combination Plier
    • RUP8 Roll up pouch

Specifications: Fluke 117 Electrician's Multimeter plus insulated hand tools starter kit

Fluke 117 Electrician's Multimeter Specifications:

Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, NEDA 1604A / IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer.
OhmsRange/resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)2Range/resolution99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy0.1% + 2
  1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
  2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
  3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
  4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years
Screwdriver TypeBlade length
(inches
mm)
Handle length
(inches
mm)
Handle width
(inches
mm)
Bladeform diameter
(inches
mm)
Head SlotSlot3
75
3-3/8
86
1
25
3/32
2.55
Head SlotSlot4
100
3-11/16
94
1 5/16
30
5/32
4.0
Head SlotSlot5
125
4-3/16
106
1 7/16
36
1/4
6.0
Head PhillipsPhillips #13
80
3-11/16
94
1 3/16
30
7/32
5
Head PhillipsPhillips #24
100
4-3/16
106
1 7/16
36
1/4
6
Pliers TypeNominal Length (inches)Nominal Length (mm)
Long Nose8200
Diagonal Cutters8200
Lineman Combination Pliers8200
 

Warranty

Fluke Insulated Hand Tool Lifetime Limited Warranty

Each Fluke Insulated Hand Tool will be free from defects in material and workmanship for its lifetime. As used herein, “lifetime” is defined as seven years after Fluke discontinues manufacturing the product, but the warranty period shall be at least fifteen years from the date of purchase. This warranty does not cover damage from neglect, misuse, contamination, alteration, accident or abnormal conditions of operation or handling, damage or normal wear and tear of mechanical components. This warranty covers the original purchaser only and is not transferable.

Recommendations for use and in-service care of Fluke Insulated Hand Tools

The following is guidance concerning the maintenance, inspection, retest and use of Fluke Insulated Hand Tools.

Warning – to avoid electrical shock or personal injury:

  • Keep fingers behind the finger guards of the tool. Never touch conductive parts.
  • Always wear approved eye protection.
  • Do not use in wet or damp locations. Do not use unless the tool is clean and dry.
  • Do not apply excessive force or stress to the tool insulation that may cause damage. Examples include using the insulated surfaces as a fulcrum to pry or wedge or gripping insulated tool handles with other tools such as pliers or wrenches to increase torque or leverage.

If the tool is used in a manner not specified, the protection may be impaired.

Storage

Insulated hand tools should be properly stored to minimize the risk of damage to the insulation due to storage or transportation. These insulated hand tools should be stored separated from other tools to avoid mechanical damage or confusion with uninsulated tools. Furthermore, these insulated hand tools should be prevented from contact with excessively hot surfaces (for example steam pipes) or exposure to excessive UV- radiation.

Inspection before use

Before use, each Insulated Hand Tool should be visually inspected by the user. If there is any doubt concerning the safety of the insulated hand tool, it should be subjected to examination by a competent person and if necessary retested to determine suitability or disposed of to prevent further use.

Temperature

Insulated Hand Tools should be used only in environments having temperatures between –20 °C and +70 °C and, for tools marked “C”, between –40 °C and +70 °C.

Periodic examination and electrical retesting

An annual visual examination by a suitably trained person is recommended to determine the suitability of the Insulated Hand Tool for further service. If an electrical retest is required by national regulation or in the case of doubt after visual examination, the applicable dielectric test of IEC 60900 for insulated hand tools should be performed.

For details contact a Fluke Service Center.

Models: Fluke 117 Electrician's Multimeter plus insulated hand tools starter kit

IB117K

117 Electrician’s Multimeter + Insulated Hand Tools Starter Kit (5 insulated screwdrivers and 3 insulated pliers)

Buy it

Includes:

  • Fluke 117 Electrician's Multimeter
  • ISLS3 Insulated Slotted Screwdriver 3/32, 3"
  • ISLS5 Insulated Slotted Screwdriver 5/32, 4"
  • ISLS8 Insulated Slotted Screwdriver 1/4, 5"
  • IPHS1 Insulated Phillips Screwdriver #1, 3"
  • IPHS2 Insulated Phillips Screwdriver #2, 4"
  • INLP8 Insulated Long Nose /w Side Cutter and Gripping Zones
  • INDC8 Insulated Heavy Duty High Leverage Diagonal Cutter
  • INCP8 Insulated Heavy Duty Linesman Combination Plier
  • RUP8 Roll up pouch
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 127.87ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.44ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.