Fluke 101 Digital Multimeter/i400E Clamp Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.64ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 101 Digital Multimeter 1
  • Fluke 101 Digital Multimeter 2
  • Fluke 101 Digital Multimeter 3
  • Fluke 101 Digital Multimeter 4

Key features

Fluke 101 Basic Digital Multimeter

  • Basic dc accuracy 0.5%
  • CAT III 600 V safety rated
  • Diode and continuity test with buzzer
  • Small lightweight design for one-handed use
  • Rugged, durable design
  • Automatic shutdown
  • Battery is easy to replace

Fluke i400E AC Current Clamp

  • Compatible with most Fluke multimeters or mV ac measurement tools with these features:
    • 400 mV ac range
    • 19.05 mm banana jack inputs
    • Input accuracy of 2 % or greater to take full advantage of the accuracy of the product
    • Input impedance of >1 M?
  • 1 mV/A ac output guarantees easy current readings on you meter
  • CAT III 600 V safety rating
  • Specially designed to offer maximum utility in a very compact shape
  • Take accurate current readings

Product overview: Fluke 101 Digital Multimeter/i400E Clamp Kit

Designed for basic electrical tests, the Fluke 101 digital multimeter offers reliable measurements for residential/commercial electricians and heating and air conditioning technicians. This small, lightweight multimeter fits comfortably in your hand but is rugged enough to withstand daily use for years to come. When it comes to professional-grade affordable multimeters, the Fluke 101 digital multimeter is your best choice.

The Fluke i400E AC Current Clamp is an ideal tool to extend current measurement. It is designed to work with the new Fluke 101, 106 and 107 palm sized digital multimeters, as well as most Fluke multimeters or other voltage measurement tools that accepts 19.05 mm shrouded banana plugs and has mV ac measurement functionality.

Specifications: Fluke 101 Digital Multimeter/i400E Clamp Kit

Fluke 101 Basic Digital Multimeter

Electrical specifications
V AC (40-500Hz)Range600.0 mV
6.000 V
60.00 V
600.0 V
Resolution0.1 mV
0.001 V
0.01 V
0.1 V
Accuracy3.0% ±3 digit
1.0% ±3 digit
V DCRange6.000 V
60.00 V
600.0 V
Resolution0.001 V
0.01 V
0.1 V
Accuracy0.5% ±3 digit
Resistance OhmsRange400.0 Ω
4.000 kΩ
40.00 kΩ
400.0 kΩ
4.000 MΩ
40.00 MΩ
Resolution0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy0.5% ±3 digit
0.5% ±2 digit
0.5% ±2 digit
0.5% ±2 digit
0.5% ±2 digit
1.5% ±3 digit
CapacitanceRange50.00 nF
500.0 nF
5.000 µF
50.00 µF
100.0 µF
Resolution0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
Frequency
(10 Hz – 100 kHz)
Range50.00 Hz
500.0 Hz
5.000 kHz
50.00 kHz
100.0 kHz
Resolution0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
0.1 kHz
Duty cycleRange0.1% to 99.9%
Resolution0.1%
General specifications
CAT ratingCAT III 600 V
V AC range600.0 V
V DC range600.0 V
Ohms range40.00 MΩ
Auto shutoffY
ContinuityY
Capacitor100.0 µF
Frequency100.0 kHz
HoldNo
Duty cycleYes
Size130 x 65 x 27mm
Weight160 g
BatteryTwo AAA
Warranty1 year
Environmental specifications
Operating temperature0 °C to +40 °C
Storage temperature-30 °C to +60 °C
Operating humidityNon condensing (<10 °C)
<=90% RH (at 10 °C to 30 °C)
<=75% RH (at 30 °C to 40 °C)
(Without condensation)
Operating humidity, 40 MΩ80% RH 10 °C to 30 °C, 70% RH 30 °C to 40 °C
Operating altitude2,000 meters
Storage altitude12,000 meters
IP ratingIP 40 per IEC 60529
Vibration requirementsMIL-PRF-28800F, Class 2
Drop test requirements-10°C and 1 meter to surface, per IEC-61010-1, and Fluke SOP 39.1 for portable Hand-held equipment
Shipping container drop per Fluke SOP 39.
EMI, RFI, EMCMust meet all applicable requirements in
IEC/EN 61326-1
Absorption/corrosionPer Fluke SOP 39.1
Temperature coefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 ºC

Fluke i400E AC Current Clamp

Electrical specifications
AC current range

1 A to 400 A

Output signal 1mV/A ac
Accuracy2.0% ±5 digits (45 Hz to 65 Hz)
2.5% ±5 digits (65 Hz to 400 Hz)
Typical bandwith5 Hz to 20 kHz
Working voltage600 V ac rms, in compliance with IEC 61010-1 and IEC 61010-2-030
Load impedance1 A to 400 A
Maximum non-destructive current600 A
Jaw inner diameter30 mm
Maximum wire size600 MCM
Standard plugs19.04 mm dual banana plugs
Safety specifications
Category ratingIEC 61010-1 and IEC 61010-2-030/IEC 61010-2-031 and
IEC 61010-2-032: 600 V CAT III
Pollution Degree 2
Electromagnetic environmentIEC 61326-1: Portable
General specifications
Output cable length1 m
Operating temperature-10 °C to +50 °C
Storage temperature-30 ºC to +60 ºC
Relative humidity≤90% at 10 °C to 530 °C
≤75% at 30 °C to 540 °C
≤45% at 40 °C to 50 °C
IP ratingIEC 60529: IP30 when jaw closed
Temperature coefficientsAdd 0.1 x specified accuracy for each °C above 28°C or below 18 °C.
Operating altitude2,000 meters
Storage altitude12,000 meters
Vibration requirementsMIL-PRF-28800F, Class 2
Drop test requirements-10 °C, 1m, 6 sides, oak wood
Jaw impact test requirementsFollow EN/IEC 61010-2-032:2012
EMI, RFI, EMCIEC/EN 61326-1
Dimensions (H x W x D)146 x 62 x 34 mm
Weight150 g

Models: Fluke 101 Digital Multimeter/i400E Clamp Kit

Fluke 101 Kit

Buy it
Includes:
  • Fluke 101 Basic Digital Multimeter
  • Tl75 Hard Point Test Lead Set
  • Two AAA Batteries (Installed)
  • Smart Strap
Fluke 101/i400E Kit

Buy it
Includes:
  • Fluke 101 Basic Digital Multimeter
  • Fluke i400E AC Current Clamp
  • Tl75 Hard Point Test Lead Set
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.54ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.37ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.