Solar Tools Kit with 87V Max Digital Multimeter and Test Leads

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 123.85ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  •  Fluke Solar Kit 3
  •  Fluke Solar Kit 3
  •  Fluke Solar Kit 3
  •  Fluke Solar Kit 3
  •  Fluke Solar Kit 3

Key features

  • Withstands drops up to 4-meters (13 feet) with industrial strength casing and holster
  • Waterproof, dustproof IP67 case for the most extreme work sites
  • Meter rated to CAT III 1000 V / CAT IV 600 V
  • Solar PV test lead sets are designed for use with meters that accept 4mm banana plugs, rated to CAT III 1000 V / CAT IV 600 V

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
A$1,334.30
Tax included where applicable
Genuine Fluke Product
Free shipping

Product overview: Solar Tools Kit with 87V Max Digital Multimeter and Test Leads

The 87V MAX is the ideal electrical troubleshooting solution for solar inverters, combiner boxes and battery storage systems. The 87V MAX is built with an IP67 rated, industrial-strength case and a removable holster. The holster doubles as a test probe holder for easier, one-handed operation. This meter is fully waterproof and dust proof keep working reliably no matter where your job takes you. Safely connect the Solar PV test leads to the meter to validate voltage from individual panels or a series of panels in a PV array.

Key functions of the solar clamp meter and Solar PV test leads:

  • Measure voltage of PV arrays safely and accurately
  • IP67 rated meter can withstand harsh outdoor environments
  • Meter is designed to survive drops up to 4-meters (13 feet)
  • Solar PV leads comply to IEC / EN 61010-031

Solar Tools Kit with 87V Max Digital Multimeter and Test Leads

What's in the box:

  • Fluke 87V MAX True-rms Digital Multimeter
  • TL175 TwistGuard® test leads
  • AC175 Alligator clips
  • 80BK-A temperature probe
  • Removable holster with test lead storage
  • Three AA batteries (installed) 
  • Pomona PVLEAD1 Solar PV to 4 mm Test Lead Set

Specifications: Solar Tools Kit with 87V Max Digital Multimeter and Test Leads

 

Specifications: Fluke 87V MAX True-rms Digital Multimeter

Electrical Specifications
DC VoltageRange0.1 mV to 1000 V
Accuracy±(0.05% + 1)
Maximum resolution0.1 mV
AC VoltageRange0.1 mV to 1000 V
Accuracy±(0.7% + 4) true-rms
AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution0.1 mV
DC CurrentRange0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy±(0.2% + 2)
Maximum resolution0.1 µA
AC CurrentRange0.1 μA to 10 A
(20 A for 30 seconds maximum)
Amps accuracy±(1.0% + 2) true-rms
Maximum resolution0.1 µA
ResistanceRange0.1 Ω to 50 MΩ
Accuracy±(0.2% + 1)
Maximum resolution0.1 Ω
CapacitanceRange0.01 nF to 9999 μF
Accuracy±(1% + 2)
Maximum resolution0.01 nF
FrequencyRange0.5 Hz to 199.99 kHz
Accuracy±(0.005% + 1)
Maximum resolution0.01 Hz
Duty cycleMaximum duty cycle99.9%
Accuracy±(0.2% per kHz + 0.1%)
Maximum resolution0.1%
Temperature measurement range–200.0 °C to 1090 °C (–328.0 °F to 1994.0 °F)
excluding probe
80 BK temperature probe–40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater
(–40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater)
ConductanceMaximum conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum resolution0.01 nS
Diode testRange2 V
Resolution0.001V
Accuracy±(1% + 1)
Diagnostics and data storagePeak Min/Max250 μS
Min/Max/AvgYes
Reading hold/Auto (Touch) HoldYes
Relative referenceYes
DisplayDigital6000 counts updates 4/second
19,999 counts in high–resolution mode
Analog bar graph32 segments, updates 40/second
BacklightTwo level
Low pass filter (VFD measurements)Yes
Input Alert™Yes
Safety Specifications
Safety ratingIEC61010-1: Pollution Degree 2
IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V
Agency approvalsCE, CSA
Mechanical and General Specifications
IP ratingIEC 60529: IP67
PowerThree AA batteries. 800 hours typical, without backlight
Size6.0 x 10.1 x 21.5 cm (with holster)
Weight698.5 g (with holster)
WarrantyLimited lifetime
Environmental Specifications
Operating temperature-15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C
Storage temperature-40 °C to + 60 °C
Humidity (without condensation)0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating altitude2000 m
 

Specifications: Pomona PVLEAD1 MC4 to 4 mm Test Lead Set

 PVLEAD1PVLEAD3
MC4 to 4mm Test Lead SetMC4 Solar Clamp Meter Test Lead Set
ContactBrass, Nickel PlatedBrass, Nickel Plated
Length60”36”, 12”
VoltageCAT III 1000V,CAT III 1000V,
CAT IV 600VCAT IV 600V
Current20 amp20 amp
StandardsIEC 61010-031IEC 61010-031
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 110.15ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.02ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.