English

Fluke 3000 FC Series Wireless Multimeter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.64ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke 3000 FC Series Wireless Multimeter
  • Fluke 3000 FC Series Wireless Multimeter
  • Fluke 805 FC Vibration Meter
  • Fluke 3000 FC Series Wireless Multimeter

Key features

  • Full featured multimeter that also reads results wirelessly from remote Fluke Connect® wireless modules
  • Measures AC and DC voltage to 1000 V, AC and DC current, and temperature
  • Shows up to four readings simultaneously on a bright white backlit display
  • Sends measurement data to your smartphone
  • Safety rated CAT III 1000 V, Cat IV 600 V; IP54

Special offers

In stock
A$836.00
Tax included where applicable
Genuine Fluke product
Free shipping

Product overview: Fluke 3000 FC Series Wireless Multimeter

The Fluke 3000 FC with Fluke Connect provides all the facts right in the field.

With its precision, reliability, and ease of use, the Fluke 3000 FC Wireless Multimeter has all the essential electrical and electronic troubleshooting features professional technicians need. It gives you true-RMS voltage and current measurements, 6000-count resolution, manual and automatic ranging, plus a frequency, capacitance, resistance, continuity and diode measurements.

Reduces arc flash risk

Independently tested for safe use in CAT IV 600V/CAT III 1000 V environments, the Fluke 3000 FC DMM and Fluke Connect wireless modules put tools, not your body, near live electrical panels. Just de-energize the cabinet; open the panel while wearing PPE; and connect the remote modules—voltage modules, current clamps, flexible current loops or thermometers. Then read the results on the 3000 FC from a safe distance up to away. You can view the meter measurement, plus readings from up to three wireless modules all on the same screen. And by separating yourself from hazardous measurement situations you’ll reduce the risk of arc flash.

Gives the full picture in real time.

With Fluke Connect-enabled tools you can connect multiple remote modules in different parts of the system and view the interaction between remote test points on a single screen, in real time. Create and email reports right from the field, or download the data to a PC for further analysis. The Fluke 3000 FC connects to your smartphone through Bluetooth so you can send measurement data from the meter to your phone and share it with your team anytime, from anywhere.

Other useful capabilities:

  • Record measurements over time and monitor changes live on your phone.
  • Share the results using Fluke Cloud™ storage and ShareLive™ video call.
  • Provides True-RMS voltage and current measurements with 6000-count resolution
  • Share results with remote team members instantly with ShareLive™ video call
  • Includes continuity, resistance, diode test, capacitance, and frequency tests, plus MIN/MAX recording
  • Provides 0 09% basic accuracy
  • Works with a standard amp clamp or with a flexible iFlex clamp
  • Shows meter measurement and readings from up to three modules simultaneously
  • Allows mixing and matching modules to meet your specific measurement needs
  • Current, voltage and temperature modules are available separately or in Fluke Connect kits
  • Runs on three AA Alkaline batteries, providing 250 hours minimum battery life
  • Comes with three-year standard warranty
 
 Fluke 115 Field Technicians Digital MultimeterFluke 87V Industrial MultimeterFluke 3000 FC Series Wireless MultimeterFluke 1587 FC Insulation MultimeterFluke 279 FC True-rms Thermal Multimeter
CAT ratingCAT III 600 VCAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
True-rms readings
Voltage AC/DC600 V1000 V1000 V1000 V1000 V
Current AC/DC10 A10 A400 mA400 mA2500 A AC (with iFlex)
Resistance40 MΩ50 MΩ50 MΩ50 MΩ50 MΩ
Capacitance10,000 μF10,000 μF10,000 μF10,000 μF10,000 μF
Temperature--200.0 °C to 1090 °Cwith t3000 FC-40 °C to 537 °CInfrared camera
-10 °C to 200 °C
Infrared camera----
Additional
measurement
capabilities
Continuity/diode testFrequency,
continuity/diode test,
motor drive (VFD)
measurement,
duty cycle,
microamps, analog
bar graph, relative
reference
Frequency,
continuity/diode test.
Able to connect to
three 3000 FC
modules.
Frequency, Pi/DAR
timed ratio tests,
continuity/diode test, motor drive (VFD)
measurement,
microamps, relative
reference
Frequency,
continuity/diode test,
motor drive (VFD)
measurement

What's in the box:

  • Fluke 3000 FC True-RMS Wireless Multimeter
  • (1 pair) TL175 Test Leads
  • (1 pair) AC175 Alligator Clips
  • Quick reference guide

Specifications: Fluke 3000 FC Series Wireless Multimeter

AC Voltage
Range¹ / resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ± (2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
mVRange / resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
mA AC
(45 Hz to 1 kHz)
Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy1.5% + 3
mA DC2Range1 / resolution60.00 mA / 0.01 mA
400.0 mA3 / 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy10.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 60 dB, DC to 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Overload protection1100 V RMS
Input impedance (nominal)> 10 MΩ < 100 pF
Common mode rejection ratio
(1 kΩ unbalance)
> 120 dB at DC, 50 Hz or 60 Hz
Normal mode rejection> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
< 0.7 V DC
< 0.9 V DC
Typical short circuit current< 350 mA
Overload protection1100 V RMS
Input impedance (nominal)< 2.7 V DC
Full scale voltage to 6 MΩ
Full scale voltage 50 MΩ
2.000 V DC
Typical short circuit current< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions± 12 counts for changes > 350 mS in duration.
AC functions± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20m
Obstructed, sheetrock wallUp to 6.5m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 X (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326–1:2006, EN 61326–2–2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68–FDMMBLE IC: 6627A–FDMMBLE
Safety complianceANSI / ISA 61010–1 / (82.02.01): 3rd edition
CAN / CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010–1: 3rd edition
IEC / EN 61010–1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Models: Fluke 3000 FC Series Wireless Multimeter

FLK-3000 FC
Fluke 3000 FC Series Wireless Multimeter
Find a distributor

Includes:

  • True-RMS Wireless Multimeter
  • TL175 Test Leads
  • AC175 Alligator Clips
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 52.16ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.9ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.

Manuals + resources: Fluke 3000 FC Series Wireless Multimeter