Principales fonctions

  • Detect live voltage even when the batteries are dead
  • 3 forms of AC/DC voltage indication: light, sound, and vibration for added user protection and convenience
  • Backlit LCD display and hold function for easier viewing in hard-to-test areas

Présentation du produit: Fluke T+Pro Electrical Tester

Safer than solenoid testers and fully compliant with NFPA 70E*, the T+Pro helps electricians and technicians work safer by indicating the presence of voltage even when the batteries are dead due to its solid-state design. Additional functionality such as a GFCI trip, easy to read LCD screen, resistance measurement up to 9.99 kOhms and a flashlight make the T+Pro the first voltage tester that electricians reach for.

Detect live voltage even when the batteries are dead

  • Not only shows the presence of voltage but indicates the level even when the batteries are dead
  • Fully compliant with NFPA 70E*

3 forms of AC/DC voltage indication: light, sound, and vibration for added user protection

  • Three voltage indications ensure that the user will be alerted to the presence of voltage even in dark or noisy environments.
  • The audible indication can be optionally disabled at the push of a button

Backlit LCD display and hold function for easier viewing in hard-to-test areas

  • A bright backlit display allows for easy voltage or resistance readings in dark environments
  • An included HOLD function will freeze the display for even easier reading

Key safety features

  • Solid-state tester design will detect voltage even when the batteries are dead
  • CAT IV 600 V, CAT III 1000 V
  • Complies with NFPA 70E*
  • CSA Approved

Additional product features

  • GFCI trip for testing outlet GFCI circuits
  • Rotary field indicator
  • Built in flashlight for measuring point illumination
  • Convenient probe storage on the back
  • 2 year warranty

Related resources

 

*When used properly per Article 110.4 Use of Equipment (A) Test Instruments and Equipment.

Spécifications: Fluke T+Pro Electrical Tester

Specifications
TemperatureOperating-10°C to 55°C (14°F to 131°F)
Storage-30°C to 60°C (-22°F to 140°F)
Relative Humidity90%0°C to 30°C (32°F to 86°F)
75%30°C to 40°C (86°F to 104°F)
45%40°C to 50°C (104°F to 122°F)
AltitudeOperating2,000 m (approx. 6,561.6 ft)
Storage10,000 m (approx. 32,808.4 ft)
Battery Type/LifeAAA (2); 40 hours
Shock, VibrationSinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument
SafetyISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV
Compliance to NFPA 70E1
AC Bandwidth45 Hz to 66 Hz
Maximum Working Voltage1000 V AC/DC
Maximum Measurable Voltage600 V AC/DC
Duty CycleIndefinitely for voltages up to 240 V
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s
Voltage Hazard LEDLEDs turn on at voltages > 30 V AC/DC ±35%
LED Voltage Indication Levels12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V
LEDsLEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100%
LCD AccuracyAC voltage±(3% rdg + 2 digits)
DC voltage±(2% rdg + 2 digits)
Resistance±(5% rdg + 3 digits)
LCD Resolution0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V
0.01 kΩ for resistance measurement
GFCI Test Current100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA
Standard Input Test Current< 5 mA
Size (H x W x L)1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm )
Weight9.9 oz (0.28 kg)
1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment.

Modèles: Fluke T+Pro Electrical Tester

Fluke T+PRO
Fluke T+PRO Electrical Tester
Acheter

Includes:

  • User manual
  • Test lead wrap
  • TP2 test probes