5800A Oscilloscope Calibrator

  • No image available
No se fabrica
Este producto ya no se fabrica o se reclasificó

Descripción general del producto: 5800A Oscilloscope Calibrator

Especificaciones: 5800A Oscilloscope Calibrator

5800A Mainframe Specifications
Voltage DCRange:   0 to ±6.6V (50Ω)
Range:   ±0.25%
 ------------
Range:   0 to ±130V (1 MΩ)
Best 1 Year Specification:   ±0.025%
Voltage AC (SquarewaveRange:   : 0 to ±6.6V (50Ω)
Best 1 Year Specification:   ±0.25%
 --------
Range    ±1 mV to ±130V p-p (1 MΩ)
Best 1 Year Specification:   ±0.05%
Fast EdgeRange:   4 mV to 2.5V p-p (50Ω)
Best 1 Year Specification:   300 ps Rise Time
Leveled SinewaveRange:   50 kHz to 600 MHz
Best 1 Year Specification:   50 kHz to 600 MHz
 ±1.5% Flatness
Time MarkersRange:   5s to 500 ps
 Spike, square, 20% pulse, sine
Best 1 Year Specification:   ±1 ppm
Wave GeneratorRange:   Range: 1.8 mV to 55V p-p (1 MΩ)
 1.8 mV to 2.5V p-p (50Ω)
 0.01 Hz to 100 kHz
 Square, Sine, Triangle
Best 1 Year Specification:   ±3
Pulse GeneratorRange:   15 mV to 1.5V amplitude
Best 1 Year Specification:   1 ns to 500 ns width ±5%
Best 1 Year Specification:   1 ns to 500 ns width ±5%
DC Voltage MeasurementRange:   0 to ±6.6V
Best 1 Year Specification:   : ±0.05%
Current DCRange:   ±100 mA to ±100 mA
Best 1 Year Specification:   ± 0.25%
Current ACRange:   100 mA p-p to 100 mA p-p
 10 Hz to 100 kHz
 Squarewave
Best 1 Year Specification:   ±0.25%
TV TriggerNTSC, SECAM, PAL, PAL-M
Input Impedance MeasurementRange:   40Ω to 1.5 MΩ
Best 1 Year Specification:   ±0.1%
 --------
Range:   5 pF to 50 pF
Best 1 Year Specification:   ±5%
Overload Measurement5V to 9V (dc or ac squarewave), 5 to 60 seconds
5800A with GHz Option
Voltage DCRange:   0 to ±6.6V (50Ω)
Range:   ±0.25%
 ------------
Range:   0 to ±130V (1 MΩ)
Best 1 Year Specification:   ±0.025%
Voltage AC (SquarewaveRange:   : 0 to ±6.6V (50Ω)
Best 1 Year Specification:   ±0.25%
 --------
Range    ±1 mV to ±130V p-p (1 MΩ)
Best 1 Year Specification:   ±0.05%
Fast EdgeRange:   4 mV to 2.5V p-p (50Ω)
Best 1 Year Specification:   300 ps Rise Time
Leveled SinewaveRange:   50 kHz to 2.1 GHz (with Option)
Best 1 Year Specification:   50 kHz to 2.1 GHz ± 1.5% Flatness
Time MarkersRange:   5s to 500 ps
 Spike, square, 20% pulse, sine
Best 1 Year Specification:   ±1 ppm
Wave GeneratorRange:   Range: 1.8 mV to 55V p-p (1 MΩ)
 1.8 mV to 2.5V p-p (50Ω)
 0.01 Hz to 100 kHz
 Square, Sine, Triangle
Best 1 Year Specification:   ±3
Pulse GeneratorRange:   15 mV to 1.5V amplitude
Best 1 Year Specification:   1 ns to 500 ns width ±5%
 20 ms to 200 ns period ± 1 ppm
DC Voltage MeasurementRange:   0 to ±6.6V
Best 1 Year Specification:   : ±0.05%
Current DCRange:   ±100 mA to ±100 mA
Best 1 Year Specification:   ± 0.25%
Current ACRange:   100 mA p-p to 100 mA p-p
 10 Hz to 100 kHz
 Squarewave
Best 1 Year Specification:   ±0.25%
TV TriggerNTSC, SECAM, PAL, PAL-M
Input Impedance MeasurementRange:   40Ω to 1.5 MΩ
Best 1 Year Specification:   ±0.1%
 --------
Range:   5 pF to 50 pF
Best 1 Year Specification:   ±5%
Overload Measurement5V to 9V (dc or ac squarewave), 5 to 60 seconds
General Specifications
Warm up TimeTwice the time since last warmed up, to a maximum of 30 minutes
Settling Time5 seconds or faster for all functions and ranges
Standard InterfacesIEEE-488 (GPIB), RS-232
Temperature PerformanceOperating:   0oC to 50oC
Calibration (tcal):  15oC to 35oC
Storage:     -20oC to 70oC
Electromagnetic CompatibilityDesigned to operate in Standard Laboratory environments where the Electromagnetic environment is highly controlled. If used in areas with Electromagnetic fields > 1 V/m, there could be errors in output values.
Temperature CoefficientTemperature Coefficient for temperatures outside tcal + 5 oC is 0.1X/oC of 1-year specifications.
Relative HumidityOperating:   < 80% to 30 oC, < 70% to 40 oC, < 40% to 50 oC
AltitudeNon-operating:   12,200m (40,000 ft) maximum
Operating:   3,050m (10,000 ft) maximum
SafetyDesigned to comply with IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010, 1-92
Analog Low Isolation20V
EMCComplies with EN 61326-1
Line PowerLine Voltage (selectable): 100V, 120V, 220V, 240V Line Frequency: 47 to 63 Hz Line Voltage Variation: + 10% about line voltage setting
Power ConsumptionConsumption 250VA
DimensionsHeight:  17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit
Width:   43.2 cm (17 in), standard rack width
Depth:   47.3 cm (18.6 in) overall
Chatee con nuestroasistente de Fluke
Borrar el chat