Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect is rated 2.0 out of 5 by 1.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.97ms
  • REVIEWS, PRODUCT
  • Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect
  • Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect
  • Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect
  • Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Key features

  • Reports distance to multiple bridge taps up to 3,200 feet (975 m)
  • Includes test leads with ABN and piercing pin clips
  • Tests opens and shorts up to 8,000 feet (2.4 km)
  • SmartTone for exact pair identification, built-in TDR and toner
  • AC/DC voltage detection, one-button testing

Product overview: Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Fluke Networks Cable fault finder with PowerBT™ Bridge Tap Detect provides open/short circuit detection—to 8,000 feet (2.4 km) and locates multiple bridge taps up to 3,200 feet (975 m) of cable, built-in toner has five tones and patented SmartTone®for exact pair identification, reports AC/DC voltage on any two conductor, telephone, security wires, or coax cables.

Specifications: Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect

Maximum Length8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable types, and 500 feet (152 meters) on cables with high loss. The tester shows -Err if the cable is too long to be correctly measured.
Representative Maximum Cable Length8,000 feet (2,438 meters): CAT-3 Twisted Pair
8,000 feet (2,438 meters): CAT-5 Twisted Pair
6,000 feet (1,830 meters): 12/2 AC Wire
3,000 feet (900 meters): RG-6/U TV Coax
1,500 feet (457 meters): RG-174/U Coax
Minimum LengthNo minimum length (can read a bridge tap at 0 feet/meters). Minimum non-zero reading is 2 feet or 1 meter.
Length Accuracy"±2 feet (±0.6 m) for cables less than 10 feet (3 m)
±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m)
+/-3%+/-5 feet (±2 m) for cables longer than 200 feet (60 m)"
Distance to Bridge Tap0 feet to 3,200 feet (975 meters)
Minimum Length of Bridge Tap10% of the distance to the bridge tap. Dependent on the cable characteristics.
Measurement RateMaximum of 4 complete measurements per second, decreasing to 2 seconds per measurement based on cable size and uniformity.
VOPAdjustable from 20 to 99, saved in flash memory.
Test TechnologyTime Domain Reflectometry (TDR) with 100 Ω drive impedance, 6v maximum pulse height.
Cable TypeVirtually all two or more conductor cables.
Power4 AA alkaline batteries.
Reverse Battery ProtectionNo damage to the tester will occur if the batteries are installed backwards.
Battery Life35 hours (typical)
Low Battery IndicationLED display alternates between LO and bAtt when the battery voltage falls below 4.5v.
Maximum Output Voltage4 voltage peak
Maximum Isolation Voltage250 volts RMS
Voltage MeasurementsRange: 0 volts AC to 115 volts AC; 0 volts DC to ±150 volts DC
Accuracy: AC: +/-1%+/-2 volts (45 Hz to 65 Hz); DC: +/-1%+/-2 volts DC
High Voltage DetectionAC voltage detected to 115 volts; DC voltage detected to ±150 volts.
AC voltage ≥90 volts or DC voltage ≥100 volts causes high voltage warnings to show on the display
SmartTone® (5-tones) Range7,000 feet (2,134 meters)
Toner Range52,800 feet (16,093 meters)
Tone InjectionApproximately 1 kHz at an amplitude of 80% of battery voltage. Variable frequency and cadence. Tone characteristics change as cable condition changes to “normal-open” from any other condition.
Impedance Range35 Ω to 330 Ω with auto-compensation within this range. Cables with impedances outside this range will not be properly tested and may produce erratic or incorrect readings.
Temperature RangeOperating: 32°F to 104°F (0°C to 40°C)
Storage: 32°F to 131°F (0°C to 55°C)
HumidityOperating: 20% to 80% relative humidity
Storage: 0% to 100% relative humidity
Operating Humidity80% maximum at 86°F (30°C )
50% maximum at 104°F (40°C )
Operating Altitude9,843 ft max (3,000 m max)
Weight1 lb (454 grams)
Dimensions7.4 in x 2.7 in x 1.4 in (18.8 cm x 6.9 cm x 3.6 cm)
SafetyIEC 61010-1:2010; N10140
EMC: IEC/EN61326-1:2006
Certifications and ComplianceConforms to relevant European Union directives
Conforms to relevant Australian standards
IEC/EN61010-1 CAN/CSA-C22.2 No. 1010.1-92 + CSA-C22.2 No. 1010.1B-97, UL/ANSI 3111-1
Notes: Patents 6160405, 6285195, 6323654, and 6509740. Specifications subject to change without notice.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 70.09ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 2 out of 5 by from TIME DOMAIN REFLECTOMETER It is not a graphical time domain reflectometer which would provide a visual indication of the cable's condition over the entire length. Total confidence must be given to this type of an instrument when test a cable with multiple defects and or splices. Therefore, I avoided purchasing this tool. I am looking forward to Fluke providing the field with an affordable handheld graphical TDR like the Greenlee Sidekick or the Megger CFL510. For that matter, why not an all-in-one cable tester for the electrical contractor? This would include the TDR, cable length meter, megger, locater tone generator, and VOM.
Date published: 2022-01-23
  • y_2024, m_10, d_10, h_4
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_4629315616820, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.87ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.

Manuals + resources: Fluke Networks TS100-PRO-BT-TDR Cable Fault Finder with Bridge Tap Detect