Fluke 107 Palm-sized, CAT III Digital Multimeter
Compare products: digital multimeters
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 87V Industrial Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 179 True-RMS Digital Multimeter
- Fluke 117 Electrician's Multimeter with Non-Contact Voltage
- Fluke 115 Field Technicians Digital Multimeter
- Fluke 177 True-RMS Digital Multimeter
- Fluke 289 True-RMS Data Logging Multimeter
- Fluke 28 II Rugged Digital Multimeter
- Fluke 116 Digital HVAC Multimeter
- Fluke 287 True-RMS Electronics Logging Multimeter
- Fluke 3000 FC Series Wireless Multimeter
- Fluke 114 Electrical Multimeter
- Fluke 113 Digital Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke 77 IV Digital Multimeter
- Fluke v3000 FC Wireless AC Voltage Module
- Fluke v3001 FC Wireless DC Voltage Module
- Fluke 1587 FC Insulation Multimeter
Key features
- CAT III 600 V safety rating
- Current and voltage measurements
- Measures resistance and continuity to check for broken wires
- Data hold and backlit display to keep you working safe and fast
Product overview: Fluke 107 Palm-sized, CAT III Digital Multimeter
The Fluke 107 is a compact, palm size easy-to-use digital multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool; small enough to fit in a shirt pocket yet tough enough to withstand daily use, including a 1-meter drop test. For everyday applications where true-rms accuracy isn’t needed, the Fluke 107 delivers reliable measurements time after time. With a CAT III 600 V safety rating, you don’t need to compromise safety. The Fluke 107 offers a comfortable grip, weighs only 200 g, and is easy to carry.
Fluke 107 measurement test functions
- AC and DC voltage
- AC and DC current
- Resistance
- Capacitance
- Diode
- Frequency and duty-cycle
Fluke 107 comes ready to work
The Fluke 107 comes with a TL75 Hard Point™ Test Lead Set. It’s one pair (red, black) of 48 inch (1.22 meter) test leads with right-angle, shrouded banana plugs. The meter also includes a SmartStrap™ intelligent magnetic multi-purpose lanyard that lets you hang the Fluke 107 from any ferrous surface or support the meter at an angle for easy viewing.
What's in the box:
- Fluke 107 palm-sized digital multimeter
- (1 pair) TL75 Hard Point™ Test Leads
- (2) AAA batteries (installed)
- SmartStrap™ intelligent magnetic, multi-purpose lanyard
- 1-year warranty.
Specifications: Fluke 107 Palm-sized, CAT III Digital Multimeter
Accuracy is available for one year after calibration, operating from 18 °C to 28 °C and relative humidity from 0% to 75%. The format of the accuracy specification is: ± ([% of reading] + [least significant digit])
Precision specifications | ||||
AC voltage (40 Hz to 500 Hz)1 | Range | Resolution | Accuracy | |
6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 1.0 % + 3 | ||
DC voltage | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 0.5 % + 3 | |
Exchange millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
Diode test2 | 2.000 V | 0.001 V | 10 % | |
Resistance (ohm) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 | |
Capacitor3 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | |
Frequency4 Hz (10 Hz – 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz | 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz | 0.1 % + 3 | |
Duty cycle4 | 1 % to 99 % | 0.10 % | 1 % typical case5 | |
AC current (40 Hz - 200 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
DC | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
| ||||
Features | Overload protection | Input impedance (nominal value) | Common mode rejection ratio | Normal mode rejection ratio |
AC voltage | 600 V 1 | >10 MΩ <100 pF 2 | >60 dB at 50 Hz or 60 Hz at DC current | − |
Exchange millivolts | 600 mV | >1M, <100 pF | >80 dB at 50 Hz or 60 Hz | − |
DC voltage | 600 V 1 | >10 MΩ <100 pF | >100 dB at 50 Hz or 60 Hz at DC current | >60 dB at 50 Hz or 60 Hz |
| ||||
General technical indicators | ||||
The highest voltage applied to any terminal and ground | 600 V | |||
Display (LCD) | 6000 counts, updated three times per second | |||
Type of battery | Two AAA batteries (NEDA 24A, IEC LR03) | |||
Battery life | At least 200 hours | |||
Temperature | ||||
Operating temperature | 0 °C to 40 °C | |||
Storage temperature | -30 °C to 60 °C | |||
Relative humidity | ||||
Working humidity | No condensation below 10 °C ≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C | |||
Working humidity, 40 MΩ range | ≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C | |||
Altitude | ||||
Working elevation | 2000 m | |||
Storage altitude | 12,000 m | |||
Temperature coefficient | 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) | |||
Current input fuse protection | 11A, 1000V fast-melting type, must use Fluke designated parts | |||
Volume (height x width x length) | 142 mm x 69 mm x 28 mm | |||
Weight | 200 g | |||
Protection level | IEC 60529: IP 40 | |||
Safety | IEC 61010-1: 600 V CAT III, pollution degree 2 | |||
Electromagnetic environment | IEC 61326-1: Portable | |||
Electromagnetic compatibility | Applicable only in Korea. Class A equipment (industrial broadcasting and communication equipment)1 | |||
1 This product meets the requirements of industrial (Class A) electromagnetic wave equipment, which should be noted by the seller or user. The device is suitable for use in a work environment, not a home environment. |
Models: Fluke 107 Palm-sized, CAT III Digital Multimeter
Fluke 107 Palm-sized, CAT III Digital Multimeter
Includes:
- Fluke 107 Palm-sized, CAT III Digital Multimeter
- TL75 Hard Point™ Test Lead Set
- Two AAA batteries (installed)
- SmartStrap™ intelligent magnetic multi-purpose lanyard