Fluke 289 IMSK Industrial Multimeter Service Kit
Key features
- True-RMS accuracy with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording give you the results you need.
- Fluke-i400 AC 400A Current Clamp turns the 289 into a clamp meter.
- Safety rated CAT III 1000 V, CAT IV 600 V meter to get you home safely from the job.
Product overview: Fluke 289 IMSK Industrial Multimeter Service Kit
This combo kit is built around the Fluke 289, Fluke’s next-gen high performance industrial logging multimeter, combined with the i400 AC current clamp. Together, they help solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. The kit includes special accessories to make you even more productive on the job and will save over 15% compared with the individually priced items. Plus, you'll be working with the most trusted tools in the world.
Fluke 289 DMM Features
- Provides the ability to log data and graphically
- TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
- Review up 10,000 recorded events and logged readings with on-board TrendCapture
- Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
- Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
- Includes premium test leads, alligator clips, and amp jack plugs
Fluke i400 AC Current Clamp Features
- Provides accurate current measurements up to 400 A ac without breaking electric circuits.
- Flexible, heat resistant test leads and alligator clips complete this high-performance kit.
- Soft non-slippery over mold handle prevents from accidental touching live wiring
- Max. conductor Ø 32 mm
1000V voltage detection range for wide range of applications use
- Measures up to 1000 V AC/DC voltage
- Measures up to 10 A AC/DC current
- Measure resistance up to 500 MΩ
- Measure frequency up to 1000 kHz max
Safety Features
- Rated for CAT III 1000 V for added protection
- Rated for CAT IV 600 V for added protection
- CE and CSA approved
Specifications: Fluke 289 IMSK Industrial Multimeter Service Kit
Specifications for 289 | ||
Function | ||
DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.025% | |
AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.4% (True-RMS) | |
DC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.05% | |
AC current | Range / resolution | 500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.6% (True-RMS) | |
Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
Basic accuracy | 1.0% | |
Resistance | Range / resolution | 50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ |
Basic accuracy | 0.05% | |
Capacitance | Range / resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF |
Basic accuracy | 1.0% | |
Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
Basic accuracy | 0.005% | |
Connectivity | Optional infrared connector via Fluke ir3000 FC |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 6 AA alkaline batteries, NEDA 15A IECLR6 | |
Battery life | 100 hours minimum, 200 hours in logging mode | |
Temperature | Operating | -20°C to 55°C |
Storage | -40°C to 60°C | |
Relative humidity | 0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
Electromagnetic compatibility | EMC EN61326–1 | |
Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
Shock | 1-meter drop per IEC/EN 61010–1 3rd Edition | |
Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
Weight | 870.9 g (28 oz) | |
Multiple on screen displays | Yes | |
True-RMS AC bandwidth | 100 kHz | |
dBV/dBm | Yes | |
DC mV resolution | 1 μV | |
Megohm range | Up to 500 MΩ | |
Conductance | 50.00 nS | |
Continuity beeper | Yes | |
Battery/fuse access | Yes/Yes | |
Elapse time clock | Yes | |
Time of day clock | Yes | |
Min-max-avg | Yes | |
Duty cycle | Yes | |
Pulse width | Yes | |
Isolated optical interface | Yes | |
Auto/touch hold | Yes | |
Reading memory | Yes | |
Log to PC | Yes | |
Interval/event logging | Yes | |
Logging memory | Up to 15,000 readings | |
Wireless connectivity (optional) |
Specifications: Fluke i400 AC Current Clamp | |
Nominal current range | 400 A |
Continuous current range | 1 A - 400 A |
Maximum non-destructive current | 1000 A |
Lowest measurable current | 1 A |
Basic accuracy | 2% + 0.06 A |
(45-400 Hz) | |
(% reading + floorspec) | |
Useable frequency | 5 Hz - 20 kHz |
Output level(s) | 1 mA/A |
Safety Specifications | |
Safety | CAT IV 600 V, CAT III, 1000 V |
Maximum voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 |
Mechanical and General Specifications | |
Warranty | 1 year |
Maximum conductor diameter | 32 mm (1.25 in) |
Maximum conductor size (busbar) | 750 MCM |
Output cable length | 1.5 m (59 in) |
Shrouded banana plugs | Yes |
Models: Fluke 289 IMSK Industrial Multimeter Service Kit
FLUKE-289/IMSK
FLUKE-289/IMSK,INDUSTRIAL MULTIMETER SERVICE KIT
Includes:
- Fluke 289 True-RMS Data Logging Multimeter
- Fluke i400 400A AC Current Clamp
- TL71 Flexible Silicone Test Lead Set
- AC175 Threaded Alligator Clip Set
Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication
how do I get the 289 to accept the I400 clamp? I know how to plug it in. The instructions show only the feed current through the meter option, not the clamp. I bought the 289 last year so maybe it does not accept the i400 clamp option?
I think I found out the answer. using the 1000mA/A ratio of the clamp on, if the meter reads 1000mA then the actual amp through wire is 1A
Date published: 2024-03-14