Key features

  • True-RMS accuracy with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording give you the results you need.
  • Fluke-i400 AC 400A Current Clamp turns the 289 into a clamp meter.
  • Safety rated CAT III 1000 V, CAT IV 600 V meter to get you home safely from the job.
“…Tactically, a good reason to get the i400 clamp for your DMM instead of a dedicated clamp meter is that using a clamp you can put the display where you want it.”- verified purchaser

Product overview: Fluke 289 IMSK Industrial Multimeter Service Kit

This combo kit is built around the Fluke 289, Fluke’s next-gen high performance industrial logging multimeter, combined with the i400 AC current clamp. Together, they help solve complex problems in electronics, plant automation, power distribution, and electro-mechanical equipment. The kit includes special accessories to make you even more productive on the job and will save over 15% compared with the individually priced items. Plus, you'll be working with the most trusted tools in the world.

Fluke 289 DMM Features

  • Provides the ability to log data and graphically
  • TrendCapture graphically displays logged data session to quickly determine whether anomalies may have occurred.
  • Review up 10,000 recorded events and logged readings with on-board TrendCapture
  • Zoom on trend provides unprecedented ability to view and analyze TrendCapture data; zoom in up to 14 times.
  • Low Pass filter for accurate voltage and frequency measurements at the same time on adjustable speed motor drives and other electrically noisy equipment.
  • Includes premium test leads, alligator clips, and amp jack plugs

Fluke i400 AC Current Clamp Features

  • Provides accurate current measurements up to 400 A ac without breaking electric circuits.
  • Flexible, heat resistant test leads and alligator clips complete this high-performance kit.
  • Soft non-slippery over mold handle prevents from accidental touching live wiring
  • Max. conductor Ø 32 mm

1000V voltage detection range for wide range of applications use

  • Measures up to 1000 V AC/DC voltage
  • Measures up to 10 A AC/DC current
  • Measure resistance up to 500 MΩ
  • Measure frequency up to 1000 kHz max

Safety Features

  • Rated for CAT III 1000 V for added protection
  • Rated for CAT IV 600 V for added protection
  • CE and CSA approved

Specifications: Fluke 289 IMSK Industrial Multimeter Service Kit

Specifications for 289
Function
DC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.025%
AC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.4% (True-RMS)
DC currentRange / resolution500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.05%
AC currentRange / resolution500.00 μA, 5000.0 μA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.6% (True-RMS)
Temperature (excluding probe)Range / resolution-200.0°C to 1350.0°C (-328.0°F to 2462.0°F)
Basic accuracy1.0%
ResistanceRange / resolution50.000 Ω, 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Basic accuracy0.05%
CapacitanceRange / resolution1.000 nF,10.00 nF 100.0 nF, 1.000 μF, 10.00 μF, 100.0 μF, 1000 μF, 10.00 mF, 100 mF
Basic accuracy1.0%
FrequencyRange / resolution99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Basic accuracy0.005%
ConnectivityOptional infrared connector via Fluke ir3000 FC
General Specifications
Maximum voltage between any terminal and earth ground1000 V
Battery type6 AA alkaline batteries, NEDA 15A IECLR6
Battery life100 hours minimum, 200 hours in logging mode
TemperatureOperating-20°C to 55°C
Storage-40°C to 60°C
Relative humidity0 to 90% (0 to 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)
Electromagnetic compatibilityEMC EN61326–1
VibrationRandom vibration per MIL-PRF-28800F Class 2
Shock1-meter drop per IEC/EN 61010–1 3rd Edition
Size (H x W x L)22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in)
Weight870.9 g (28 oz)
Multiple on screen displaysYes
True-RMS AC bandwidth100 kHz
dBV/dBmYes
DC mV resolution1 μV
Megohm rangeUp to 500 MΩ
Conductance50.00 nS
Continuity beeperYes
Battery/fuse accessYes/Yes
Elapse time clockYes
Time of day clockYes
Min-max-avgYes
Duty cycleYes
Pulse widthYes
Isolated optical interfaceYes
Auto/touch holdYes
Reading memoryYes
Log to PCYes
Interval/event loggingYes
Logging memoryUp to 15,000 readings
Wireless connectivity (optional) 
Specifications: Fluke i400 AC Current Clamp
Nominal current range400 A
Continuous current range1 A - 400 A
Maximum non-destructive current1000 A
Lowest measurable current1 A
Basic accuracy2% + 0.06 A
(45-400 Hz)
(% reading + floorspec)
Useable frequency5 Hz - 20 kHz
Output level(s)1 mA/A
Safety Specifications
SafetyCAT IV 600 V, CAT III, 1000 V
Maximum voltage1000 V AC rms from earth to ground, in compliance with EN61010
Mechanical and General Specifications
Warranty1 year
Maximum conductor diameter32 mm (1.25 in)
Maximum conductor size (busbar)750 MCM
Output cable length1.5 m (59 in)
Shrouded banana plugsYes

Models: Fluke 289 IMSK Industrial Multimeter Service Kit

FLUKE-289/IMSK

FLUKE-289/IMSK,INDUSTRIAL MULTIMETER SERVICE KIT

 


Buy it

Includes:

  • Fluke 289 True-RMS Data Logging Multimeter
  • Fluke i400 400A AC Current Clamp
  • TL71 Flexible Silicone Test Lead Set
  • AC175 Threaded Alligator Clip Set

Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication

how do I get the 289 to accept the I400 clamp? I know how to plug it in. The instructions show only the feed current through the meter option, not the clamp. I bought the 289 last year so maybe it does not accept the i400 clamp option?

Asked by: geno
I think I found out the answer. using the 1000mA/A ratio of the clamp on, if the meter reads 1000mA then the actual amp through wire is 1A
Answered by: geno
Date published: 2024-03-14
  • y_2024, m_11, d_10, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_en_US, sid_4329920659508, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.44ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.19ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.