Fluke 106 Palm-sized Digital Multimeter
Model#: Fluke 106
Key features
- AC and DC voltage measurement
- AC and DC current measurement
- Resistance measurement
- Capacitance measurement
- Compact 142 mm x 69 mm x 28mm size
Product overview: Fluke 106 Palm-sized Digital Multimeter
The Fluke 106 is a compact, easy-to-use multimeter made to fit the way you work. It is the perfect first-pass troubleshooting tool: small enough to fit in a shirt pocket or work bag, tough enough to withstand daily use, and extremely simple to use. All without compromising safety. For everyday applications, where true-rms accuracy isn’t needed, the Fluke 106 delivers reliable measurements time after time.
What's in the box:
- Fluke 106 Digital Multimeter
- TL75 Hard Point™ Test Lead Set
- Two AAA Batteries (installed)
Specifications: Fluke 106 Palm-sized Digital Multimeter
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])
| Accuracy Specifications | ||||
| Function | Range | Resolution | Accuracy | |
| AC Volts (40 Hz to 500Hz)1 | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 1.0 % + 3 | |
| DC Volts | 6.000 V 60.00 V 600.0 V | 0.001 V 0.01 V 0.1 V | 0.5 % + 3 | |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | |
| Resistance (Ohms) | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ | 0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ | 0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5% + 3 | |
| Capacitance2 | 50.00 nF 500.0 nF 5.000 μF 50.00 μF 500.0 μF 1000 μF | 0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF | 2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 | |
| AC Current (40 Hz to 200 Hz) | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
| DC Current | 4.000 A 10.00 A | 0.001 A 0.01 A | 1.5 % + 3 | |
| ||||
| Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
| AC Volts | 600 V 1 | >10 MΩ <100 pF 2 | >60 dB at dc, 50 Hz or 60 Hz | − |
| \AC Millivolts | 600 mV | >1M <100 pF | >80 dB at 50 Hz or 60 Hz | − |
| DC Volts | 600 V 1 | >10 MΩ <100 pF | >100 dB at dc, 50 Hz or 60 Hz | >45 dB at 50 Hz or 60 Hz |
| ||||
| General Specifications | ||||
| Maximum Voltage Between any Terminal and Earth Ground | 600 V | |||
| Display (LCD) | 6000 counts, updates 3/sec | |||
| Battery Type | 2 AAA, NEDA 24A, IEC LR03 | |||
| Battery Life | 200 hours minimum | |||
| Temperature | ||||
| Operating | 0 °C to 40 °C | |||
| Storage | -30 °C to 60 °C | |||
| Relative Humidity | ||||
| Operating Humidity | Non-condensing when <10°C ≤90 % at 10 °C to 30 °C; ≤75 % at 30 °C to 40 °C | |||
| Operating Humidity, 40 MΩ Range | ≤80 % at 10 °C to 30 °C; ≤70 % at 30 °C to 40 °C | |||
| Altitude | ||||
| Operating | 2000 m | |||
| Storage | 12,000 m | |||
| Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) | |||
| Fuse Protection for Current Inputs | 11A, 1000V Fast Fuse, Fluke specified part only | |||
| Size (HxWxL) | 142 mm x 69 mm x 28mm | |||
| Weight | 200 g | |||
| IP Rating | IEC 60529: IP 40 | |||
| Safety | IEC 61010-1: 600 V CAT III, Pollution Degree 2 | |||
| Electromagnetic Environment | IEC 61326-1: Portable | |||
| Electromagnetic Compatibility | Applies to use the Korea only. Class A Equipment (Industrial Broadcasting and Communication Equipment)1 | |||
| ||||
Models: Fluke 106 Palm-sized Digital Multimeter
Fluke 106
Fluke 106 Palm-sized Digital Multimeter
Includes:
- Fluke 106 Palm-sized Digital Multimeter
- Tl75 Hard Point Test Lead Set
- 2 AAA Batteries (Installed)
- User’s Manual