Fluke 802EN Vibration Meter

  • Fluke 802
  • Fluke 802
  • Fluke 802
  • Fluke 802

Key features

  • Three test modes to meet complex test environment in industrial field
  • High repeatability to ensure accuracy of continuous testing
  • One-button measurement to get assessment result in 6 seconds
  • 99 sets of data storage, review in real-time

Product overview: Fluke 802EN Vibration Meter

Fluke 802EN Vibration Meter

One-button vibration assessment of mechanical equipment

Specifications: Fluke 802EN Vibration Meter

Internal Piezoelectric Accelerometer
Sensitivity (typical) 10.00 mV / m/s² ± 5% (1 g = 9.8 m/s²)
Measurement
Acceleration Range 0.1 m/s² to 199.9 m/s² peak (rms √2)
Resolution 0.1 m/s²
Accuracy ± (5 % + 2 dgt) (LO: 10 Hz to 1 kHz)
± (10 % + 5 dgt) (HI: 1 kHz to 10 kHz)
Velocity Range 0.1 mm/s to 199.9 mm/s rms
Resolution 0.1 mm/s
Accuracy ± (5% + 2 dgt) (10 Hz to 1 kHz)
Displacement Range 0.001 mm to 1.999 mm peak-peak (rms 2√2)
Resolution 0.001 mm
Accuracy ± (5 % +2 dgt) (10 Hz to 1 kHz)
Piezoelectrical Accelerometer
Typical frequency response 10 Hz to 15 kHz
Amplitude Units
Acceleration g, m/s²
Velocity mm/s
Displacement mm
External Piezoelectrical Accelerometer
DC bias voltage 6 V dc to 7 V dc
DC bias current 3.5 mA
Note: Other specifications are the same as those of the internal piezoelectric accelerometers
Battery 2 AAA, IEC LR03
Battery life 25 hrs for measurement
Dimensions (L x W x H) 24.1 x 7.1 x 5.8 cm
Weight 220 g
Audio port Stereo audio output jack (3.5 mm Audio Plug)
External sensor port M12 plug
Environment
Operating temperature -10 °C to 50 °C
Storage temperature -30 °C to 60 °C
Operating humidity 30% to 90% RH (non-condensing)
Operating altitude 2,000 m
Storage altitude 12,000 m
Ingress Protection IP 40
Vibration limit 500.0 m/s² peak
Drop test 1 m
Electromagnetic Compatibility (EMC) International IEC 61326-1: Portable, Industrial Electromagnetic Environment; CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.

Models: Fluke 802EN Vibration Meter

FLUKE-802EN

Buy it
Chat with ourFluke assistant
Clear Chat