Fluke TIC122 Non-Contact High Voltage Detector
Key features
- Verifies presence of voltage from 30 VAC to 122,000 VAC (122 kV) without contacting the conductor
- Simple two level electricity tester provides:
- High voltage (1,000 V to 122 kV AC) setting to check transmission lines, power distribution equipment, down power lines and load break connectors
- Low voltage (30 to 1,000 V AC) setting to check for voltage in breaker panels, breakers, power outlets, fuses and wiring
- Non-contact AC voltage detection warns that voltage is present with bright flashing lights and loud beeps
- Push button self-test verifies that tester is working properly
- Ergonomic design includes a convenient handle and a universal adapter for use with Fluke 410A Hot Stick attachment to extend reach
- Drop-proof to 6 feet (1.8 m)
Product overview: Fluke TIC122 Non-Contact High Voltage Detector
The Fluke TIC122 high voltage detector is a non contact voltage detector designed to identify the presence of AC voltage on transmission lines, power distribution equipment, downed power lines, fuses, electrical outlets, and other energized conductors. It detects voltage in low, medium, and high voltage applications from 30 V AC to 122 kV AC, with bright visual and loud audible alerts.
Built for demanding environments, the Fluke TIC122 provides reliable performance for utility, industrial, and heavy manufacturing applications. The detector is designed to withstand the rough handling typical of utility field use.
The presence of AC voltage is indicated through a bright LED light and an audible beeper. The voltage detector also features a built-in self test to verify proper operation and is drop tested up to 6 feet for durability in the field.
Specifications: Fluke TIC122 Non-Contact High Voltage Detector
| Specifications | TIC122 |
| Operating Voltage | LOW Range: 30 V AC to 1000 V AC HIGH Range: 1000 V AC to 122 kV AC *Use only with optional accessory hot stick and proper safety equipment when voltage exceeds 1000 V |
| Operating Temperature | -25°C to +55°C (-13°F to +131°F); RH 20% to 96% |
| Storage Temperature | -25°C to +55°C (-13°F to +131°F); RH 20% to 96% |
| Environment | <3000m, outdoor operation |
| IP rating | IP54 |
| Power | 6 x AAA alkaline battery |
| Power Consumption | OFF: 340uA Low / High Detection mode: 39 mA |
| Duty Cycle | Continuous |
| Response Time | Instantaneous |
| Dimensions | 345(L) x 75(W) x 47(H)mm (13.5 x 3.0 x 1.8 in) |
| Weight | 350g (0.8 lb.) |
| Supplied with | Battery and carrying case |
| Range | |
| Non-Contact Voltage Detection | 30-1000 VAC 1000- 122,000 VAC (with Fluke 410A Hot Stick) |
| Typical | Sensitivity |