Key features

  • Automatic pressure generation and regulation to 1000psi
  • Replaceable pressure control modules
  • Built-in test templates, one-key calibration
  • HART communication
  • Pressure leakage testing
  • Automatic fine-pressure adjustment, automatic pressure stabilization
  • Powerful, replaceable Li-ion battery
  • Quick pressure release valve with a muffler
  • Extend measurement range with 750P Series pressure modules
  • Measure temperature with 720RTD probe
  • Bright dual-three-channel /color graphic display
  • Weight <5kg
  • Rugged and portable design with standard 3-year warranty
  • Absolute and gage pressure modules up to 7MPa.
  • Use the modules to change the Fluke 729Pro to a different output pressure range

Product overview: Fluke 729 Pro Automatic Pressure Calibrator

Fluke 729 Pro Automatic Pressure Calibrator not only simplifies pressure calibration but saves time, reduces errors and improves accuracy. With plug-in replaceable pressure control modules and pressure generation and regulation up to 1000psi, 7Mpa.

Specifications: Fluke 729 Pro Automatic Pressure Calibrator

Key parameters729 Pro 7M729 Pro 4M
Pressure control range-13 to 1000 psi, -90 to 7000 kPa,
-0.90 to 70 bar
-13 to 600 psi, -90 to 4000 kPa,
-0.90 to 40 bar
Pressure typeGauge/absolute (Depends on the type of internal or external pressure module
Pressure accuracy and Control stability0.02% of FS, 0.005% of FS
Replaceable pressure measurement modulesYes, 6 modulesYes, 4 modules
mA sourcing/measurementYes
Voltage measurementYes
Loop power24 V dc
Pressure switch testingYes
Pressure leakage testingYes
HART CommunicationYes, basic commands supported
Autostep / auto rampYes (with customizable speed, mode and style)
BatteryRechargeable lithium battery with charge indication (charged in the instrument or separately)
LanguageEnglish
Electrical specification
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range.
Ranges
mA measure, source and simulate0 mA to 24 mA
Volts dc measurement0 V dc to 30 V dc
Resolution
mA dc source, simulate and measure1 μA
Voltage dc measurement1 mV
Accuracy0.01% FS ±2 LSD all ranges (at 23 °C ±5 °C)
Stability20 ppm FS /°C (-10 °C to +18 °C and 28 °C to 50 °C)
mA simulation working voltage12 V dc to 30 V dc
Loop compliance voltage24 V dc @ 20 mA
Temperature measurement , 100 Ω Pt(385) RTD-50 °C to 150 °C
Temperature resolution0.01 °C
Temperature accuracy±0.1 °C ±0.25 °C combined uncertainty when using 720 RTD probe (optional accessory)
Drive capability (mA source)1200 Ω (without HART resistor), 950 Ω (with internal HART resistor)
Mechanical specification
Dimension (HxWxL)290 x 215 x100 mm, (4.3 x 4.4 x 9.4 in)
Weight4.9 kg, (10.8 lbs)
Environmental specification
Operating temperature-10 °C to 50 °C
Pressure control0 °C to 50 °C
Battery charging0 °C to 40 °C
Storage temperature-20 °C to 60 °C
Operating altitude<3000 m
Storage altitude<13000 m
Operating humidityNon-condensing (<10°C)
≤90 % RH (10 °C to 30 °C)
≤75 % RH (30 °C to 40 °C)
≤45 % RH (40 °C to 50 °C)
Pressure Module Selection Table
Pressure modulePressure typeRangeResolutionOverall uncertainty729Pro 4M729Pro 7M
FLK-PMM-200KGauge(-15 to 30) psi0.0001 psi0.02 % FS / year, maximum
(-100 to 200) kPa0.001 kPa
(-1 to 2) bar0.00001 bar
FLK-PMM-200KAAbsolute(0 to 30) psi0.0001 psi0.05 % FS / year, maximum
(0 to 200) kPa0.001 kPa
(0 to 2) bar0.00001 bar
FLK-PMM-2000KGauge(-13 to 300) psi0.001 psi0.02 % FS / year, maximum
(-90 to 2000) kPa0.01 kPa
(-0.90 to 20) bar0.0001 bar
FLK-PMM-4000KGauge(-13 to 600) psi0.01 psi0.02 % FS / year, maximum
(-90 to 4000) kPa0.01 kPa
(-0.90 to 40) bar0.0001 ba
FLK-PMM-7000KGauge(-13 to 1000) psi0.01 psi0.02 % FS / year, maximum 
(-90 to 7000) kPa0.01 kPa
(-0.90 to 70) bar0.0001 ba
FLK-PMM-7000KAAbsolute(0 to 1000) psi0.01 psi0.02 % FS / year, maximum 
(0 to 7000) kPa0.01 kPa
(0 to 70) bar0.0001 ba
Dry air or non-corrosive gases only / 15 °C to 35 °C, all ranges

Models: Fluke 729 Pro Automatic Pressure Calibrator

FLK-729Pro 7M
Fluke 729Pro Automatic Pressure Calibrator 1000 psi
Buy it
  • FLK-PMM-7000K
  • FLK-PMM-200K (Optional)
  • FLK-PMM-200KA (Optional)
  • FLK-PMM-2000K (Optional)
  • FLK-PMM-4000K (Optional)
  • FLK-PMM-7000KA (Optional)
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 147.52ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.31ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.