English

Fluke 417D Laser Distance Meter / 62 MAX+ IR Thermometer Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.44ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke 417D Laser Meter / 62 MAX+ IR Thermometer Kit
  • Fluke 417D Laser Meter / 62 MAX+ IR Thermometer Kit
  • Fluke 417D Laser Distance Measurer
  • 62 MAX+
  • Fluke 417D Laser Distance Measurer

Key features

Fluke 417D Laser Meter

  • The Fluke 417D laser meter is accurate, durable, and easy to use—just point and shoot
  • Instantly measure up to 40 m (131 ft.) with 1-button point-and-click

Fluke 62 MAX+ IR Thermometer

  • Distance to spot: 12:1
  • Dual lasers: Identifies area to be measured

Product overview: Fluke 417D Laser Distance Meter / 62 MAX+ IR Thermometer Kit

The HVAC Troubleshooting Kit

The most rugged Fluke 62 MAX+ IR thermometer teamed with the easy-to-use 417D Laser Distance Meter has everything you need to configure HVAC layouts and troubleshoot electrical problems. For electrical devices use the IR thermometer to test overheating issues and for HVAC layout, use the 417D to configure layout distance or area and use continuous measurement for marking references.

Fluke 417D Laser Distance Meter Additional Features:

  • Continuous measurement capable: adjusting as you move closer and farther from your target
  • Quickly calculate area (sq. feet/meters)
  • 1-meter drop tested and IP54 rated: built to withstand rainy or dusty conditions
  • Great for interior and exterior applications

Fluke 62 MAX+ IR Thermometer Additional Features:

  • Dust and water-resistant: IP54 rated
  • Rugged: 3-meter (9.8-foot) drop tested
  • Ergonomically designed: Completely redesigned for a more natural hand fit
  • Large, backlit display: Makes data easier to read, even in dark areas

Specifications: Fluke 417D Laser Distance Meter / 62 MAX+ IR Thermometer Kit

Fluke 417D Laser Distance Meter

417D
Typical range [1]0.2-40 m/0.6-131 ft
Typical measuring tolerance* [1]2.0 mm ± 1.5 mm/± 0.06 in ***
Maximum measuring tolerance [2]± 3.0 mm/0.12 in ***
Accuracy up to 10m (+/-)± 2 mm
Display2 line/1 mm/1/32 in
Display illuminationYes
Laser point at distance6/30/60 mm (10/40/100 m)
AreaYes
Units setting (smallest units displayed)0,000m, 0' 00'' 1/32, 0 in 1/32
Auto laser switch off90 sec
Auto power switch off180 sec
General
Laser classII
Laser type635 nm, <1 mW
Protection classIP54
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03Up to 3,000 measurements
Size (Hx W x D)11.9 x 3.8 x 2.6 cm
Drop test1 meter
Weight (with batteries)95g (3.35 oz)
Temperature range: Storage-25 °C to 70 °C (-13 °F to 158 °F)
Temperature range: Operation-10 °C to 50 °C (14 °F to 122 °F)
Calibration cycleNot applicable
Maximum relative humidity85 % @ 20°F to 120 °F
(-7 °C to 50 °C)
SafetyCAN/CSA-C22.2 No. 61010-1-04, UL Std. No. 61010-1 (2nd Edition), ISA-82.02.01, IEC Standard No. 61010-1:2001, EN60825-1:2007 (Class II)
EMC61326-1:2006

[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C (13 °F).

[2] Applies for 10 % to 500 % target reflectivity, high background illumination, -10 °C to +50 °C (14 °F to +122 °F).

[3] Tolerances apply from 0.05 m to 10 m (0.001 ft to 32.8 ft) with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m (0.003 in/ft) between 10 m to 30 m (32.8 ft to 98.4 ft) and to 0.15 mm/m (0.005 in/ft) for distances above 30 m (98.4 ft).

[4] Applies for 100 % target reflectivity, background illumination between 10,000 lux and 30,000 lux.

[5] After user calibration. Additional angle related deviation of ± 0.01° per degree up to ± 45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ± 0.1°.

 

Fluke 62 MAX+ IR Thermometer

62 MAX+
Temperature range- 30 °C to 650 °C
(-22 °F to 1202 °F)
Accuracy (Calibration geometry with ambient temperature 23 °C +/- 2 °C)± 1.0 °C or ± 1.0 % of reading, whichever is greater
± 2.0 °C at -10 °C to 0 °C
± 3.0 °C at -30 °C to -10 °C
Optical resolution12:1
(calculated at 90 % energy)
Response time (95 %)< 300 ms (95 % of reading)
Spectral response8 to 14 microns
Emissivity0.10 to 1.00
Display resolution0.1 °C (0.2 °F)
Repeatability (% of reading)± 0.5 % of reading or ± 0.5 °C (whichever is greater)
Power1 AA alkaline battery
Battery life8 hours with laser and backlight on
Weight255 g (8.99 oz)
Size(175 x 85 x 75) mm
(6.88 x 3.34 x 2.95) inches
Operating temperature0 °C to 50 °C
(32 °F to 122°F)
Storage temperature-20 °C to 60 °C
(-4 °F to 140 °F)
(without battery)
Operating humidityNon- condensing @ ≤ 10 °C (50 °F)
≤ 90 % RH @ 10 °C (50 °F) to 30 °C (86 °F)
≤ 75 % RH @ 30 °C (86 °F) to 40 °C (104 °F)
≤ 45 % RH @ 40 °C (104 °F) to 50 °C (122 °F)
Operating altitude2000 meters above mean sea level
Storage altitude12,000 meters above mean sea level
Drop test3 meters
Implement standardQ/ASF01
Standards and agency approval
ComplianceIEC 61010-1: Pollution Degree 2
Laser safetyIEC 60825-1 Class 2, 650 nm, < 1 mW
Ingress protection ratingIP 54 per IEC 60529
Warranty3 years

Models: Fluke 417D Laser Distance Meter / 62 MAX+ IR Thermometer Kit

417D/62 MAX+

Fluke 417D/62 MAX+ Laser Distance Measurer/Infrared Thermometer Combo Kit

Find a distributor

Includes:

  • Fluke 417D Laser Distance Measurer (Meter)
  • Fluke 62 MAX+ IR Thermometer
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 50.1ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.01ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.