Fluke ii1050 Acoustic Imager

Model#: FLK-II1050
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 165.89ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;

Key features

  • Locate and quantify compressed air, gas and vacuum leaks
  • Detect and analyze partial discharge with PDQ Mode™
  • Identify mechanical issues early with MecQ™ Mode
  • Inspect energized equipment from up to 150 m away
  • Generate inspection reports directly on the device

Product overview: Fluke ii1050 Acoustic Imager

See more problems. Diagnose them faster.

The Fluke ii1050 Acoustic Imager gives maintenance and reliability teams a fast way to locate compressed air, gas and vacuum leaks, detect partial discharge, identify mechanical issues, and verify air tightness, all with one acoustic imaging platform.

SoundSight™ Acoustic Imaging Technology combines a 202-microphone array with a visible-light image to show where abnormal sounds are coming from, even in noisy industrial environments. With a 2 kHz to 100 kHz frequency range and detection capability up to 150 m (492 ft) depending on ambient conditions, the ii1050 helps technicians quickly scan equipment and investigate problems from a safe distance.  

Purpose-built analysis modes help teams move from detection to action. LeakQ™ estimates leak rate and associated energy cost to help prioritize compressed air repairs. PDQ Mode™ identifies partial discharge sources, estimates discharge probability, and displays real-time PRPD patterns for evaluating electrical assets. MecQ™ helps identify mechanical issues such as bearing defects, friction, and turbulence before they become obvious through vibration, heat, or audible noise.  

Choose the ii1050 configuration that fits your inspection needs. In addition to the standard ii1050 Acoustic Imager, available configurations add the Fluke TC03A iSee™ Thermal Camera Attachment for thermal, acoustic, and visible-light inspection in a single workflow. Other configurations add the SB140 SoundBeacon™, which works with Beacon Mode to quickly locate sealing defects during air-tightness inspections. Configurations with Fluke Premium Care are also available, with one- and three-year coverage options.  

Whichever configuration you choose, the ii1050 streamlines inspection and documentation with a 7-inch anti-glare touchscreen, 13 MP visible-light camera, 128 GB of storage, asset tagging, notes, action prioritization, and on-device reporting, helping teams find problems earlier and turn inspection results into corrective action faster.    

Specifications: Fluke ii1050 Acoustic Imager

Key Featuresii500ii1030ii1050
Sensors   
MEM (Microphones)64202202
Frequency band2 kHz to 52 kHz2 kHz to 64 kHz2 kHz to 100 kHz
Detection range10.5 to > 70 meters
(1.6 to > 164 feet)
0.5 to > 100 meters
(1.6 to > 393 feet)
0.5 to > 150 meters
(1.6 to > 492 feet)
Field of view (FOV) (typical)64°x 48°
Nominal frame rate25 FPS
Built-in digital camera (visible light)   
Field of view (FOV) (typical)64° x 48°
Focus50 cm to infinity
(20 inch)
ZoomNo zoom3 x digital zoom
Resolution
 
0.3 MP13 MP
Display   
Size7" LCD with backlight7" Anti-Glare LCD with backlight, sunlight readable
Resolution1280 x 800 (1,024,000 pixels)
TouchscreenCapacitive
Acoustic imageSoundMap™ acoustic imaging overlay
Image storage   
Storage capacity20 GB110 GB
Image formatBlended visual and SoundMap™   .JPG
Video formatBlended visual and SoundMap™   .MP4
Video lengthUp to 5 minutes
Digital exportUSB-C for data transfer
Acoustic    
Measurement range (typical)2 kHz: 15.4 ~ 115.2 dB SPL
19 kHz: 5.6 ~ 102.5 dB SPL
35 kHz: 28.4 ~ 131.1 dB SPL
52 kHz: 41.8 ~ 133.1 dB SPL
20 kHz: -10.4 ~ 122 dB SPL
25 kHz:  -24.7~ 122 dB SPL
31.5 kHz:  -13~ 122 dB SPL
40 kHz: -10.7~ 122 dB SPL
50 kHz: 8~ 122 dB SPL
Auto max/min dB gainAutoAuto or user selectable max dB
Frequency band selectionUser selectable through user-made presets or manual entry
Capture Mode   
PhotoYesYesYes
VideoYesYesYes
LeakQ™ Leak size scale (1-10)Leak size scale, rate and cost estimationLeak size scale, rate and cost estimation
PDQ Mode™ --Yes
MecQ™ --Yes
BeaconYes, works with Fluke SB140 SoundBeacon™ for airtightness detection.
Thermal-Yes, works with TC03A
Battery   
BatteryRechargeable and field replaceable Li-ion battery
Battery life6 hours (1 x 6hrs)>7 hours (2 x 3.5hrs)
Battery charging time3 hours<3 hours
Battery charging systemExternal (Bay charger)Internal (USB-C)
Software   
Ease of useIntuitive user interface
Acoustics: Show dB scaleOn/Off
Acoustics: Min/Max dBMin/MaxMax dB/Auto
Acoustics: Profiles-Preset capture profiles
Acoustics: High frequency Yes
Acoustics: Multiple sourcesSingle SourceMulti Source
Palette: Colors3: Grayscale, Ironbow, and Blue-Red
Palette: Overly transparencyYes: 1-100 %
Grayscale modeYes
Trend graphsFrequency and dB scale
Leak valuesLeakQ TM scale (1-10)Leak costs, Leak volume, LeakQ TM scale (1-10)
AnnotationAsset name; Asset ID; Asset type; Leak type; Gas type; Pressure
Photo notesUp to 4 photo notes for reference
Asset inspection status-As left', 'As found', 'Undetermined'
Asset IDText input and automatic QR code based asset ID identification
Actions annotation-Action requirement, priortity and notes
On-Device Reporting-Support (PDQ, LeakQ, PDQ+Ti, LeakQ+Ti, Ti mode)
General Specification   
Tripod holder / connector-Yes: 1/4"-20
USB1 x USB-C2 x USB-C
Wireless–Wi-Fi
Operating Temperature-10 to 45 °C
(14 to 113 °F)
Storage Temperature-20 to 70 °C 
(-4 °Fto 158 °F) without batteries installed
Operating altitudeUp to 2000 mUp to 2000 mUp to 2000 m
Storage altitudeUp to 12000 mUp to 12000 mUp to 12000 m
Relative humidity10 to 95 % RH, non-condensing
Size (H x W x L)186 x 322 x 68 mm
(7.3 x 12.7 x 2.7 inches)
235 × 154 × 46 mm
(9.25 × 6.06 × 1.81 inches)
Weight (battery included)2,1 kg
(4.6 pounds)
1,2 kg
(2.6 pounds)
Ingress Protection (IP)IP40IP54
Warranty2 year
Fluke Premium CarePremium Care Standard2
Self-diagnostic notificationArray-health test to identify when microphone array needs attention
Supported languagesArabic, Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
OS supported–––
Safety & Environmental   
RoHS compliantYes
General safetyIEC 61010-1: Pollution degree 2
Electromagnetic Compatibility (EMC) InternationalIEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A3IEC 61326-1: Industry Electromagnetic Environment, CISPR 11: Group 1, Class A
Korea (KCC)Class A4 Equipment (Industrial Broadcasting & Communication Equipment)Class A Equipment (Industrial Broadcasting and Communication)
USA (FCC)47 CFR 15 subpart B. This product is 
considered an exempt device per clause 15.103
47 CFR 15 subpart
Radio Equipment Directive (2014/53/EU) (RED)-YesYes
    
¹  Depending on ambient conditions
²  Subject to regional availability (www.fluke.com/premiumcare)
3 Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
4 Device meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

Models: Fluke ii1050 Acoustic Imager

FLK-II1050

FLK-II1050 ACOUSTIC IMAGING CAMERA


Find a distributor

Includes:

  • II1050 Acoustic Imaging Camera
  • Hard Case
  • Hand Strap
  • Neck Strap
  • RRC2040 Battery Pack (2)
  • Charger Kit (65W Wall charger, USB-C Cable, country specific connectors)
FLK-II1050/T50HZ

FLK-II1050 ACOUSTIC IMAGING CAMERA THERMAL ACC KIT


Find a distributor

Includes:

  • II1050 Acoustic Imaging Camera
  • Hard Case
  • Hand Strap
  • Neck Strap
  • RRC2040 Battery Pack (2)
  • Charger Kit (65W Wall charger, USB-C Cable, country specific connectors)
  • TC03A 50HZ Thermal Camera
  • TP01 II-SERIES Tripod
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 25.12ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.12ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat