Fluke ii1030 Acoustic Imager
Key features
- Locate compressed air, gas and vacuum leaks quickly
- Quantify leak rate and cost with LeakQ™ Mode
- Pinpoint leaks from more than 100 m away
- Verify air tightness with Beacon Mode
- Generate inspection reports directly on the device
Product overview: Fluke ii1030 Acoustic Imager
Find leaks faster. Quantify the impact. Prioritize repairs.
The Fluke ii1030 Acoustic Imager gives maintenance teams a faster way to find compressed air, gas and vacuum leaks and verify air tightness, without spending hours tracing lines or checking individual connections.
SoundSight™ Acoustic Imaging Technology uses an array of 202 digital MEMS microphones to detect ultrasonic sound and overlay its location onto a visible image. Technicians can scan large areas and quickly see where a leak is coming from, even in noisy industrial environments. With a detection range of more than 100 m depending on ambient conditions, the ii1030 also helps locate difficult-to-access leaks from a safer distance.
Finding the leak is only part of the job. LeakQ™ Mode estimates leak rate and associated energy cost, helping teams understand which leaks are costing the most and prioritize repairs accordingly. The Fluke Online LeakQ™ Reporting Tool can also estimate the CO₂ emissions associated with identified compressed air leaks.
For manufacturing and quality applications, the ii1030 also supports Beacon Mode when used with the optional Fluke SB140 SoundBeacon™. This provides a fast, non-contact way to identify sealing defects and verify air tightness in components, assemblies and equipment.
A 7-inch anti-glare touchscreen, 13 MP visible-light camera and SoundMap™ acoustic overlay make findings easy to see and document. Capture images and video, add asset information and notes, prioritize corrective actions, and generate reports directly on the instrument, helping turn inspection findings into repairs faster.
The result is a simpler workflow for finding leaks, reducing wasted energy and keeping compressed air and process systems operating efficiently.
Specifications: Fluke ii1030 Acoustic Imager
| Key Features | ii500 | ii1030 | ii1050 |
| Sensors | |||
| MEM (Microphones) | 64 | 202 | 202 |
| Frequency band | 2 kHz to 52 kHz | 2 kHz to 64 kHz | 2 kHz to 100 kHz |
| Detection range1 | 0.5 to > 70 meters (1.6 to > 164 feet) | 0.5 to > 100 meters (1.6 to > 393 feet) | 0.5 to > 150 meters (1.6 to > 492 feet) |
| Field of view (FOV) (typical) | 64°x 48° | ||
| Nominal frame rate | 25 FPS | ||
| Built-in digital camera (visible light) | |||
| Field of view (FOV) (typical) | 64° x 48° | ||
| Focus | 50 cm to infinity (20 inch) | ||
| Zoom | No zoom | 3 x digital zoom | |
| Resolution | 0.3 MP | 13 MP | |
| Display | |||
| Size | 7" LCD with backlight | 7" Anti-Glare LCD with backlight, sunlight readable | |
| Resolution | 1280 x 800 (1,024,000 pixels) | ||
| Touchscreen | Capacitive | ||
| Acoustic image | SoundMap™ acoustic imaging overlay | ||
| Image storage | |||
| Storage capacity | 20 GB | 110 GB | |
| Image format | Blended visual and SoundMap™ .JPG | ||
| Video format | Blended visual and SoundMap™ .MP4 | ||
| Video length | Up to 5 minutes | ||
| Digital export | USB-C for data transfer | ||
| Acoustic | |||
| Measurement range (typical) | 2 kHz: 15.4 ~ 115.2 dB SPL 19 kHz: 5.6 ~ 102.5 dB SPL 35 kHz: 28.4 ~ 131.1 dB SPL 52 kHz: 41.8 ~ 133.1 dB SPL | 20 kHz: -10.4 ~ 122 dB SPL 25 kHz: -24.7~ 122 dB SPL 31.5 kHz: -13~ 122 dB SPL 40 kHz: -10.7~ 122 dB SPL 50 kHz: 8~ 122 dB SPL | |
| Auto max/min dB gain | Auto | Auto or user selectable max dB | |
| Frequency band selection | User selectable through user-made presets or manual entry | ||
| Capture Mode | |||
| Photo | Yes | Yes | Yes |
| Video | Yes | Yes | Yes |
| LeakQ™ | Leak size scale (1-10) | Leak size scale, rate and cost estimation | Leak size scale, rate and cost estimation |
| PDQ Mode™ | - | - | Yes |
| MecQ™ | - | - | Yes |
| Beacon | Yes, works with Fluke SB140 SoundBeacon™ for airtightness detection. | ||
| Thermal | - | Yes, works with TC03A | |
| Battery | |||
| Battery | Rechargeable and field replaceable Li-ion battery | ||
| Battery life | 6 hours (1 x 6hrs) | >7 hours (2 x 3.5hrs) | |
| Battery charging time | 3 hours | <3 hours | |
| Battery charging system | External (Bay charger) | Internal (USB-C) | |
| Software | |||
| Ease of use | Intuitive user interface | ||
| Acoustics: Show dB scale | On/Off | ||
| Acoustics: Min/Max dB | Min/Max | Max dB/Auto | |
| Acoustics: Profiles | - | Preset capture profiles | |
| Acoustics: High frequency | Yes | ||
| Acoustics: Multiple sources | Single Source | Multi Source | |
| Palette: Colors | 3: Grayscale, Ironbow, and Blue-Red | ||
| Palette: Overly transparency | Yes: 1-100 % | ||
| Grayscale mode | Yes | ||
| Trend graphs | Frequency and dB scale | ||
| Leak values | LeakQ TM scale (1-10) | Leak costs, Leak volume, LeakQ TM scale (1-10) | |
| Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure | ||
| Photo notes | Up to 4 photo notes for reference | ||
| Asset inspection status | - | As left', 'As found', 'Undetermined' | |
| Asset ID | Text input and automatic QR code based asset ID identification | ||
| Actions annotation | - | Action requirement, priortity and notes | |
| On-Device Reporting | - | Support (PDQ, LeakQ, PDQ+Ti, LeakQ+Ti, Ti mode) | |
| General Specification | |||
| Tripod holder / connector | - | Yes: 1/4"-20 | |
| USB | 1 x USB-C | 2 x USB-C | |
| Wireless | – | Wi-Fi | |
| Operating Temperature | -10 to 45 °C (14 to 113 °F) | ||
| Storage Temperature | -20 to 70 °C (-4 °Fto 158 °F) without batteries installed | ||
| Operating altitude | Up to 2000 m | Up to 2000 m | Up to 2000 m |
| Storage altitude | Up to 12000 m | Up to 12000 m | Up to 12000 m |
| Relative humidity | 10 to 95 % RH, non-condensing | ||
| Size (H x W x L) | 186 x 322 x 68 mm (7.3 x 12.7 x 2.7 inches) | 235 × 154 × 46 mm (9.25 × 6.06 × 1.81 inches) | |
| Weight (battery included) | 2,1 kg (4.6 pounds) | 1,2 kg (2.6 pounds) | |
| Ingress Protection (IP) | IP40 | IP54 | |
| Warranty | 2 year | ||
| Fluke Premium Care | Premium Care Standard2 | ||
| Self-diagnostic notification | Array-health test to identify when microphone array needs attention | ||
| Supported languages | Arabic, Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese | ||
| OS supported | – | – | – |
| Safety & Environmental | |||
| RoHS compliant | Yes | ||
| General safety | IEC 61010-1: Pollution degree 2 | ||
| Electromagnetic Compatibility (EMC) International | IEC 61326-1: Portable Electromagnetic Environment, CISPR 11: Group 1, Class A3 | IEC 61326-1: Industry Electromagnetic Environment, CISPR 11: Group 1, Class A | |
| Korea (KCC) | Class A4 Equipment (Industrial Broadcasting & Communication Equipment) | Class A Equipment (Industrial Broadcasting and Communication) | |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103 | 47 CFR 15 subpart | |
| Radio Equipment Directive (2014/53/EU) (RED) | - | Yes | Yes |
| ¹ Depending on ambient conditions | |||
| ² Subject to regional availability (www.fluke.com/premiumcare) | |||
| 3 Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |||
| 4 Device meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |||
Models: Fluke ii1030 Acoustic Imager
FLK-II1030 ACOUSTIC IMAGING CAMERA
Includes:
- II1030 Acoustic Imaging Camera
- Hard Case
- Hand Strap
- Neck Strap
- RRC2040 Battery Pack (2)
- Charger Kit (65W Wall charger, USB-C Cable, country specific connectors)