Fluke 113 Digital Multimeter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 55ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 113 Digital Multimeter
  • Fluke 113 Digital Multimeter
  • Fluke 113 Digital Multimeter

Key features

  • VCHEK™ LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
  • Large backlit display
  • CAT IV 600 V safety rated

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
A$308.00
Tax included where applicable
Genuine Fluke Product
Free shipping

Product overview: Fluke 113 Digital Multimeter

The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic testing. It is easy to use and is packed with the features needed to repair most electrical problems. The 113 features a large, backlit display for easy visibility in low-lit work environments. Plus, the integrated holster includes probe holders on the back, so your test leads can always be kept organized and where you need them.

Make measurements quickly with the 113

Whether you’re a utility worker, linesman, electrician, technician, anyone else working with basic electrical testing, the Fluke 113 includes the measurement features you need to tackle your job. The Fluke VCHEK™ LoZ low impedance measurement function lets users perform tests for voltage or continuity from the same dial position.

Please note that low impedance LoZ measurements will cause a low load on a circuit protected by a RCD, which will trip powered GFCI and RCD circuits when measuring Phase to Earth.

The meter also displays AC or DC voltage, depending on what was detected, while also rejecting ghost voltages from adjacent wires.  If no voltage is detected, a continuity test is performed. The Min/Max function lets you record signal fluctuations.

The Fluke 113 digital multimeter can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.

Specifications: Fluke 113 Digital Multimeter

Specifications
VCHEK1 2 3Range6.000 V / 60.00 V / 600.0 V
Resolution0.001 V / 0.01 V/ 0.1 V
AccuracyDC, 45 to 500 Hz: 2.0% + 3
500 Hz to 1 kHz: 4.0% + 3
Diode test4Range2.000 V
Resolution0.001 V
Accuracy2.0% + 3
Continuity4AccuracyBeeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer
Ω4Range600.0 Ω / 6.000 kΩ / 60.00 kΩ
Resolution0.1 Ω / 0.001 kΩ / 0.01 kΩ
Accuracy0.9% + 2 / 0.9% + 1 / 0.9% + 1
Capacitance4Range1000 nF / 10.00 μF / 100.0 μF / 9999 μF
Resolution1 nF / 0.01 μF / 0.1 μF / 1 μF
Accuracy1.9% + 2
100 μF - 1000 μF: 1.9% + 2
1000 μF: 5% + 20
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2. Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.
4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
Specifications
Maximum voltage between any terminal and earth ground600 V
Display3 3/4-digits, 6000 counts, updates 4/sec
Operating temperature-10°C to 50°C (14°F to 122°F)
Storage temperature-40°C to 60°C (-22°F to 140°F)
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating altitude2,000 m
Storage altitude10,000 m
Relative humidity95% to 30°C
75% to 40°C
45% to 50°C
Battery type9 Volt Alkaline, IEC 6F22
Battery lifeAlkaline: 300 hours typical, without backlight
Size (H x W x L)167.1 x 85.1 x 46.0 mm (6.58 x 3.35 x 1.81 in)
Weight13.0 oz (404 g)
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT IV 600V
EMI regulationsComplies with FCC Part 15, Class B
Specifications
VCHEKInput impedance (nominal)~3 kΩ < 300 pF
VCHEKCommon mode rejection ratio
(1 kΩ unbalanced)
> 60 dB at DC, 50 or 60 Hz
ΩOpen circuit test voltage< 2.7 VDC
Full scale voltage< 0.7 VDC
Diode testOpen circuit test voltage2.7 VDC
Full scale voltage2.000 VDC
ΩShort circuit current< 350 μA
Diode testShort circuit current< 1.0 mA

Models: Fluke 113 Digital Multimeter

Fluke 113
Fluke 113 Digital Multimeter

Find a distributor

Includes:

  • Fluke TL75 test leads
  • Holster
  • Users manual
  • and 9 V battery (installed)
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 57.14ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.88ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.