Fluke 369 FC Leakage Current Clamp Meter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 62.36ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke 369 FC Leakage Current Clamp Meter
  • Fluke 369 FC Leakage Current Clamp Meter
  • Fluke 369 FC Leakage Current Clamp Meter
  • Fluke 369 FC Leakage Current Clamp Meter
  • ss:Fluke 369 FC Leakage Current Clamp Meter-5
  • Fluke 369 FC Leakage Current Clamp Meter

Key features

  • True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms
  • 61 mm jaw opening
  • Highest resolution of 1 μA, measure up to 60 A
  • Selectable filter function removes unwanted noise
  • Max/Min/Average readings and hold function
  • Forward-facing LED worklight for use in dark wiring cabinets
  • Backlit display; auto backlight off and auto power off for extended battery life
  • CAT III 600V safety rating

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
A$2,318.80
Tax included where applicable
Genuine Fluke Product
Free shipping

Product overview: Fluke 369 FC Leakage Current Clamp Meter

Reduce downtime – Find leakage currents without taking equipment offline.

The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.

The Fluke 369 FC has an oversize 61 mm jaw for work with extra-large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.

The 369 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 369 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures

What's in the box:

  • 369 FC Leakage Clamp Meter
  • Soft case
  • Two AA Batteries (Installed)
  • Quick Reference Guide

Specifications: Fluke 369 FC Leakage Current Clamp Meter

Electrical Specifications
Measurement functionAlternating current
AC ampere range3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range selectionmA / A: manual selection
3 mA / 30 mA / 300 mA: automatic selection
3 A / 30 A / 60 A: automatic selection
Range / Resolution3 mA¹ / 0.001 mA
30 mA / 0.01 mA
300 mA / 0.1 mA
3 A / 0.001 A
30 A / 0.01 A
60 A / 0.1 A
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)²3 mA – 30 A
60 A
1% + 5 digits
2% + 5 digits
Frequency40 Hz to 1 kHz
Crest Factor3
After calibration accuracy is valid for one year. Accuracy is expressed as ± (% of reading + digits). Reference conditions 23 ±5 °C and a maximum relative humidity of 80%.
¹The minimum value is 10 μA rms.
²Outside of the TC / °C 18 °C to 28 °C, 0.02 + 1
Physical
Display (LCD)Digital readout: 3300 count
Display refresh rate4 times / sec
Maximum conductor diameter61 mm
Dimensions257 x 116 x 46 mm
Weight600 g
Battery2 AA, IEC LR6, NEDA 15A, alkaline
Battery lifeExpected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-downMeter automatically shuts down after 15 minutes of inactivity
Safety and Environmental Specifications
General safetyIEC 61010-1: Pollution Degree 2
Measurement safetyIEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidityNon-condensing (<10 °C)
90% relative humidity (10 °C to 30 °C)
75% relative humidity (30 °C to 40 °C)
45% relative humidity (40 °C to 50 °C)
Protection classIEC 60529: IP30 (jaw closed)
Operating altitude2000 m
Storage altitude12000 m
Current sensor action categoryIEC 61557-13: Class 1, ≤100 A / m
Electromagnetic compatibility (EMC)
International
IEC 61326-1Industrial Electromagnetic Environment
CISPR 11Group 1 Class B
Group 1Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
Class BEquipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class AThis product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Models: Fluke 369 FC Leakage Current Clamp Meter

Fluke 369 FC
Fluke 369 FC Leakage Current Clamp Meter

Find a distributor

Includes:

  • Leakage Clamp Meter
  • Soft case
  • Safety Manual
  • Batteries: 2 AA
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 69.34ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.2ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.