Key features

  • Wide voltage detection range: Fluke TIC-122 verifies the presence of AC voltage from 30 V to 122 kV without contact.
    • High voltage 1,500 V to 122 kV AC (Only with 410A Hot Stick) setting to check transmission lines, power distribution equipment, down power lines and load break connectors
    • Low voltage 30 to 1,500 V AC setting to check for voltage in breaker panels, breakers, power outlets, fuses and wiring
  • Extended reach for safer operation: Fluke 410A Hot Stick attachment increases working distance for high-voltage, hard-to-reach applications. Extends from 33" to 57" for flexibility in the field and compact storage.
  • Quick, tool-free setup: Thread-on hot stick attachment enables quick installation without additional tools.
  • Field-ready durability: Drop-tested to 6 ft (1.8 m) for demanding environments
  • Platform compatibility: Pairs with TIC 122 and compatible with Fluke 2062

Product overview: Fluke TIC122 + 410A High Voltage Detection Kit

The Fluke TIC122 + 410A High Voltage Detection Kit provides a reliable and practical solution for detecting the presence of AC voltage across low-, medium-, and high-voltage environments. By combining the Fluke TIC122 non-contact voltage detector with the 410A Hot Stick Attachment, the kit enables safe verification of equipment while extending working distance.

Fluke TIC122

The TIC122 delivers non-contact AC voltage detection from 30 V to 122 kV, suitable for low, medium, and high voltage applications such as transmission lines, power distribution equipment, breaker panels, outlets, fuses, and downed power lines.

Bright LED indicators and an audible beeper provide clear, immediate feedback when voltage is present, allowing users to make informed decisions. Built for demanding environments, the TIC 122 features a drop-tested design rated up to 6 ft (1.8 m) for durability in the field and features a detector designed to withstand the rough handling of typical field usage.

Fluke 410A Hot Stick Attachment

When used with the 410A Hot Stick, the attachment physically and electrically extends the reach of the TIC122 high voltage detector for checking transmission lines, power distribution equipment, down power lines, fuses, and load break connectors. The Fluke 410A universal adapter extends the voltage limit on the TIC122 from 1500 V AC to 122,000 VAC (122 kV) and adjusts from 33″ to 57". This kit delivers the flexibility that professionals require to work with confidence.

Specifications: Fluke TIC122 + 410A High Voltage Detection Kit

TIC 122 Specifications

SpecificationsTIC122
Operating VoltageLOW Range: 30 V AC to 1500 V AC

HIGH Range: 1500 V AC to 122 kV AC

*Use only with optional accessory hot stick and proper safety equipment when voltage exceeds 1500 V
Operating Temperature-25°C to +55°C (-13°F to +131°F); RH 20% to 96%
Storage Temperature-25°C to +55°C (-13°F to +131°F); RH 20% to 96%
Environment<3000m, outdoor operation
Power6 x AAA alkaline battery
Power ConsumptionOFF: 340uA

Low / High Detection mode: 39 mA
Duty CycleContinuous
Response TimeInstantaneous
Dimensions345(L) x 75(W) x 47(H)mm (13.5 x 3.0 x 1.8 in)
Weight350g (0.8 lb.)
Supplied withbattery and carrying case
Range
Non-Contact Voltage30-1500 VAC
Detection1500- 122,000 VAC (with Hot Stick TIC 410A)
TypicalSensitivity

Hot Stick Specifications

SpecificationsTIC 410A Hot Stick
LengthLength (extended): 57 in
Length (collapsed): 33 in

Models: Fluke TIC122 + 410A High Voltage Detection Kit

FLUKE TIC122/410A

Non-Contact High Voltage Detector with Hot stick attachment


Find a distributor

Includes:

  • TIC122
  • Battery
  • Carrying case
  • Hot Stick attachment
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 86.38ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 25.2ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat