English

Fluke i2000 Flex AC Current Clamp

Fluke i2000 Flex AC Current Clamp is rated 4.5 out of 5 by 2.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.04ms
  • REVIEWS, PRODUCT
  • Fluke i2000 Flex AC Current Clamp

Key features

  • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600 V safety rating

Product overview: Fluke i2000 Flex AC Current Clamp

The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Specifications: Fluke i2000 Flex AC Current Clamp

Electrical specifications
Current ranges20 A
200 A
2000 A
AC rms
Output sensitivity (AC-coupled)1 mV
10 mV
100 mV
1 mV per A
Load impedance100 kΩ minimum
Accuracyat +25°C
±1% of range (45 Hz to 65 Hz)
Linearity10% to 100% of range
±0.2% of reading
Noise8 mV AC rms (30 A)
2 mV AC rms (300 A, 3000 A)
Frequency range10 Hz to 20 kHz (-3 dB)
Phase error< ±1° (45 Hz to 65 Hz)
±10° (at 20 kHz)
Position sensitivity (with cable > 25 mm from the coupling)

Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.

External wire influence: 1% (-40 db) of external current >200 mm from head.

External fieldwith cable > 200 mm from the head
±1% of range
Power supply2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
Temperature Coefficient±0.08% of reading per °C
Working voltagesee Safety standards section
600 V AC rms or DC
General Specifications
Head Circumference610 mm (24 in)
Head cable diameter14.3 mm (0.56 in)
Head bend radius38.1 mm (1.5 in)
Cable length (head to electronics)2 m (6.56 ft)
Output connectionMolded 4 mm safety plugs (not integrated)
Operating temperature range0°C to +70°C (32°F to 158°F) (head and electronics)
Storage temperature range-40°C to +105°C (-40°F to 221°F) (head)
-20°C to +85°C (-4°F to 185°F) (electronics)
Operating humidity15% to 85% (non-condensing)
Weight180 g (6.34 oz) (head)
190 g (6.70 oz) (electronics)
Safety standardsEN 61010-031: 2002
EN 61010-2-032: 2002
EN 61010-1: 2001
600 Vrms, Category III, Pollution Degree 2
Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
EMC standardsEN 61326: 1998 +A1, A2, and A3
Dimensions (H x W x D)116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)

Models: Fluke i2000 Flex AC Current Clamp

Fluke i2000 Flex
Find a distributor

Can this measure DC current above 1000 A

Asked by: bongski71
  • y_2024, m_9, d_9, h_4CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestions, tq_1
  • loc_en_US, sid_3839990923316, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 66.57ms
  • QUESTIONS, PRODUCT
Rated 4 out of 5 by from Accurate This flex CT does work well and I have had mine for many years when they first came out. The ability to wrap around several different conductors makes this a required product for the field. The problem with this product is that the inner flex is a spring that if it is stretched it is permanently damaged and must be replaced. The second problem with this product is that it cannot be calibrated so you need to check for accuracy on a regular basis to make sure you are good to go. These are the only two items where I have seen the weakness and I do recommend the product however one must take care of the equipment.
Date published: 2013-07-25
Rated 5 out of 5 by from Excellent product with Fluke 233 and wireless screen The i2000 flex probe make it possible to measure amps in a panel with very little space to work. Most clamp on meters needs space for the meter itself and in most cases you cannot reach the cores, especially if more than one core is installed. The i2000 is flexible, needs very little space and very easy to fit around cores.
Date published: 2013-06-12
  • y_2024, m_9, d_10, h_4
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_2
  • loc_en_US, sid_3839990923316, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.95ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.