Özellikler: Fluke i30 AC/DC Akım Pensi

Electrical specifications
Specified current range
30 mA to 30A dc, 30 mA to 20 A ac rms
Usable current range
5 mA to 30 A dc, 30 mA to 20 A ac rms
Crest Factor
1.4"
Output sensitivity
100 mV/A
Accuracy (at +25 °C)
± 1 % of reading ± 2 mA
Resolution
± 1 mA
Load impedance
> 10 k Ohms and ≤ 100pF
Conductor position sensitivity
± 1 % relative to center reading
Frequency range
DC to 20 kHz (- 0.5 dB)
Temperature coefficient
± 0.01 % of reading/°C
Power supply
9 V Alkaline, MN1604/PP3, 30 hours, low battery indicator
Working voltage (see Safety Standards section)
300 V ac rms or dc

 

General Specifications
Maximum conductor size
19 mm diameter
Output connection
4 mm safety connector
Output zero
Manual adjust via thumbwheel
Cable length
1.5 meters
Operating temperature range
0 °C to +50 °C
Storage temperature range (with battery removed)
-20 °C to +85 °C
Operating humidity
15 % to 85 % (non-condensing)
Weight
250 g
Safety
IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 300V
Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz.
EMC Compatibility
IEC 61326-1: Portable Electromagnetic Environment