Português

Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC

  • Fluke 902 FC True-rms HVAC Clamp Meter
  • Fluke 902 FC True-rms HVAC Clamp Meter
  • Fluke 902 FC True-rms HVAC Clamp Meter
  • Fluke 902 FC True-rms HVAC Clamp Meter

Características principais

Applications for HVAC

  • 200 µA DC current measurements to measure flame rod
  • Extended resistance range to measure thermistors up to 60kΩ
  • Capture flue gas temperature
  • Measure start and run motor capacitors
  • Measure performance of variable frequency drives

Fluke Connect

  • Fluke Connect connects your meter to your phone through Bluetooth to help you get more done faster and safer
  • Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
  • Troubleshoot better by instantly trending and monitoring measurements live on your phone screen
  • Create and email reports right from the field. Report not enough? Fluke Connect has ShareLive video calls that stream live video and measurements in the same screen
  • Don't stop to write down results, save them directly from your meter to your phone with the press of a button

Measurement capability

  • 600 A ac current measurement
  • 600 V ac and dc voltage measurement
  • Temperature measurement from -10 °C to 400 °C (14 °F to 752 °F)
  • 1000 µF capacitance measurement
  • DC Current measurement to 200 µA
  • True-rms voltage and current for accurate measurements on non-linear signals
  • Resistance measurement to 60 kΩ
  • Min and max recording to capture variations automatically

Other features

  • CAT III 600V, CAT IV 300V safety rating
  • TPAK magnetic strap (optional) allows you to conveniently hang the meter while using the probes
  • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
  • Large, easy-to-read backlit display
  • Three-year warranty
  • Soft carrying case
Todas as marcas comerciais são propriedade dos respectivos proprietários. Smartphone, serviço sem fios e plano de dados não incluídos com a compra. Grátis os primeiros 5 GB de armazenamento. Compatível com iPhone 4s e superior com iOS 8 ou superior, iPad (numa estrutura iPhone num iPad) e Galaxy S4, Nexus 5, HTC One com Android™ 4.4.x ou superior. Apple e o logótipo Apple são marcas registadas da Apple Inc., registada nos EUA e noutros países. App Store é uma marca de serviços da Apple Inc. Google Play é uma marca registada da Google Inc.

Descrição do produto: Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC

Fluke 902 FC True-rms HVAC Clamp Meter enables HVAC technicians to create reports and collaborate with peers from the work site.

The Fluke 902 FC True-rms HVAC Clamp Meter, a wireless Fluke Connect®-enabled meter, improves the productivity of HVAC technicians in the field. The rugged dual rated - CAT III, 600 /CAT IV, 300 V - meter performs the essential measurements of HVAC systems — microamps for testing pilot light sensors, resistance up to 60 kilohms, AC current, AC/DC voltage, capacitance and contact temperature — eliminating the need to carry multiple tools. Its small body is easy to hold and the jaw fits perfectly in tight work spaces.

As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. Those measurements can be uploaded to the cloud. Technicians can combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email and collaborate in real time with other colleagues with ShareLive™ video calls or email, increasing productivity in the field.

The clamp meter also decreases the frequency that technicians will need to wear personal protective equipment when working on high voltage/current panels. Simply turn off the panel, verify the panel is de-energized using standard safety procedures, place the clamp and sync it to a smartphone with the Fluke Connect app, close the panel, reenergize it, and take measurements from a safe distance.

Todas as marcas comerciais são propriedade dos respectivos proprietários. Smartphone, serviço sem fios e plano de dados não incluídos com a compra. Grátis os primeiros 5 GB de armazenamento. Compatível com iPhone 4s e superior com iOS 8 ou superior, iPad (numa estrutura iPhone num iPad) e Galaxy S4, Nexus 5, HTC One com Android™ 4.4.x ou superior. Apple e o logótipo Apple são marcas registadas da Apple Inc., registada nos EUA e noutros países. App Store é uma marca de serviços da Apple Inc. Google Play é uma marca registada da Google Inc.

Especificações: Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC

Function
A ac (via Jaw)
Resolution0.1 A
Accuracy2.0% ±5 digit (45-65 Hz)
2.5% ±5 digit (65-400 Hz)
Range600.0 A
Crest Factor (50Hz or 60Hz)2.5 MIN@220 A
> 1.4 MIN@600 A
Add 2% for CF>400 A
V ac
Resolution0.1 V
Accuracy1.5% ±5 digits
Range600.0 V
V dc
Resolution0.1 V
Accuracy1.5% ±5 digits
Range600.0 V
Ohms
Resolution0.1/1/10
Accuracy1% ±5 digits
Range600/6000/60.00 kΩ
Capacitance
Resolution0.1/1 µF
Accuracy1% ±4 digits
Range100.0/1000 µF
µA
Resolution0.1 µA
Accuracy1% ±5 digits
Range200 µA
Contact temperature
Resolution0.1 C/F
Accuracy1% ±8 digits
Range-10 to 400 °C (14 °F to 752 °F)
Continuity beeper
Beeper volume75 dBA nom. 15 cm. from case front
On threshold<=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground600 V
Battery type2 AA alkaline batteries, NEDA 15A, IEC LR6
TemperatureOperating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Operating humidityNon condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
AltitudeOperating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)
Dimensions230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
Weight (meter only)419 g (15 oz)
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
IEC 61010-2-033: CAT III 600 V / CAT IV 300 V
IP RatingIEC 60529: IP30, non-operating
Radio Frequency CertificationFCC ID:T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficientsAdd 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C
Todas as marcas comerciais são propriedade dos respectivos proprietários. Smartphone, serviço sem fios e plano de dados não incluídos com a compra. Grátis os primeiros 5 GB de armazenamento. Compatível com iPhone 4s e superior com iOS 8 ou superior, iPad (numa estrutura iPhone num iPad) e Galaxy S4, Nexus 5, HTC One com Android™ 4.4.x ou superior. Apple e o logótipo Apple são marcas registadas da Apple Inc., registada nos EUA e noutros países. App Store é uma marca de serviços da Apple Inc. Google Play é uma marca registada da Google Inc.

Modelos: Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC

FLK-902 FC

O Alicate Amperímetro HVAC 902 FC

Compre

inclui:

  • Terminais de teste TL75 (1 par)
  • Sonda de temperatura DMM integrada 80BK (1)
  • 2 pilhas alcalinas AA
  • Bolsa de transporte flexível
  • Manual do Usuário