Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC
Compare products: pinças amperimétricas
- Pinça amperimétrica 393 FC True-RMS com iFlex e classificação CAT III 1500 V
- Pinça amperimétrica AC/DC True-RMS Fluke 377 FC com iFlex
- Pinça amperimétrica AC/DC True-RMS Fluke 378 FC com iFlex
- Pinça amperimétrica CA/CC True-RMS Fluke 376 FC com iFlex®
- Pinça amperimétrica True-RMS Fluke 325
- Pinça amperimétrica AC/DC True-rms com display remoto e iFlex™ Fluke 381
- Pinça amperimétrica de corrente de fuga True-RMS para AVAC Fluke 368 FC
- Pinça amperimétrica de corrente de fuga True-RMS Fluke 369 FC
- Módulo de corrente AC sem fios Fluke a3001 FC iFlex™
- Módulo de pinça de corrente AC sem fios Fluke a3000 FC
- Pinça amperimétrica True-RMS Fluke 323
- Pinça amperimétrica True-RMS Fluke 324
- Pinça Amperimétrica True-rms AC Fluke 373
- Pinça Amperimétrica AC True-RMS Fluke 365
- Pinça amperimétrica CA/CC True-RMS Fluke 375 FC
- Pinça amperimétrica CA/CC True-RMS Fluke 374 FC
- Pinça Amperimétrica de Processos de Miliamperes Fluke 773
- Pinças amperimétricas True-RMS de 2000 A Fluke 355
- Pinças amperimétricas True-RMS de 2000 A Fluke 353
- Módulo de corrente AC/DC sem fios Fluke a3002 FC
- Pinça Amperimétrica de Processos de Miliamperes Fluke 772
- Alicate amperímetro sem fio Fluke a3003 FC 2.000 A CC
- Alicate amperímetro medidor sem fio Fluke a3004 FC 4 a 20 mA CC
- Pinça amperimétrica de processos de miliamperes Fluke 771
- Fluke T5-1000 Aparelho de teste eléctrico
- Fluke T5-600 Aparelho de teste eléctrico
Características principais
Applications for HVAC
- 200 µA DC current measurements to measure flame rod
- Extended resistance range to measure thermistors up to 60kΩ
- Capture flue gas temperature
- Measure start and run motor capacitors
- Measure performance of variable frequency drives
Fluke Connect
- Fluke Connect connects your meter to your phone through Bluetooth to help you get more done faster and safer
- Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks
- Troubleshoot better by instantly trending and monitoring measurements live on your phone screen
- Create and email reports right from the field. Report not enough? Fluke Connect has ShareLive video calls that stream live video and measurements in the same screen
- Don't stop to write down results, save them directly from your meter to your phone with the press of a button
Measurement capability
- 600 A ac current measurement
- 600 V ac and dc voltage measurement
- Temperature measurement from -10 °C to 400 °C (14 °F to 752 °F)
- 1000 µF capacitance measurement
- DC Current measurement to 200 µA
- True-rms voltage and current for accurate measurements on non-linear signals
- Resistance measurement to 60 kΩ
- Min and max recording to capture variations automatically
Other features
- CAT III 600V, CAT IV 300V safety rating
- TPAK magnetic strap (optional) allows you to conveniently hang the meter while using the probes
- Ergonomic design fits in your hand and can be used while wearing personal protective equipment
- Large, easy-to-read backlit display
- Three-year warranty
- Soft carrying case
Todas as marcas comerciais são propriedade dos respectivos proprietários. Smartphone, serviço sem fios e plano de dados não incluídos com a compra. Grátis os primeiros 5 GB de armazenamento. Compatível com iPhone 4s e superior com iOS 8 ou superior, iPad (numa estrutura iPhone num iPad) e Galaxy S4, Nexus 5, HTC One com Android™ 4.4.x ou superior. Apple e o logótipo Apple são marcas registadas da Apple Inc., registada nos EUA e noutros países. App Store é uma marca de serviços da Apple Inc. Google Play é uma marca registada da Google Inc. |
Descrição do produto: Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC
Fluke 902 FC True-rms HVAC Clamp Meter enables HVAC technicians to create reports and collaborate with peers from the work site. The Fluke 902 FC True-rms HVAC Clamp Meter, a wireless Fluke Connect®-enabled meter, improves the productivity of HVAC technicians in the field. The rugged dual rated - CAT III, 600 /CAT IV, 300 V - meter performs the essential measurements of HVAC systems — microamps for testing pilot light sensors, resistance up to 60 kilohms, AC current, AC/DC voltage, capacitance and contact temperature — eliminating the need to carry multiple tools. Its small body is easy to hold and the jaw fits perfectly in tight work spaces. As part of Fluke Connect — the industry’s largest system of software and more than 40 wireless test tools — the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. Those measurements can be uploaded to the cloud. Technicians can combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email and collaborate in real time with other colleagues with ShareLive™ video calls or email, increasing productivity in the field. The clamp meter also decreases the frequency that technicians will need to wear personal protective equipment when working on high voltage/current panels. Simply turn off the panel, verify the panel is de-energized using standard safety procedures, place the clamp and sync it to a smartphone with the Fluke Connect app, close the panel, reenergize it, and take measurements from a safe distance. |
Todas as marcas comerciais são propriedade dos respectivos proprietários. Smartphone, serviço sem fios e plano de dados não incluídos com a compra. Grátis os primeiros 5 GB de armazenamento. Compatível com iPhone 4s e superior com iOS 8 ou superior, iPad (numa estrutura iPhone num iPad) e Galaxy S4, Nexus 5, HTC One com Android™ 4.4.x ou superior. Apple e o logótipo Apple são marcas registadas da Apple Inc., registada nos EUA e noutros países. App Store é uma marca de serviços da Apple Inc. Google Play é uma marca registada da Google Inc. |
Especificações: Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC
Function | ||
A ac (via Jaw) | ||
Resolution | 0.1 A | |
Accuracy | 2.0% ±5 digit (45-65 Hz) | |
2.5% ±5 digit (65-400 Hz) | ||
Range | 600.0 A | |
Crest Factor (50Hz or 60Hz) | 2.5 MIN@220 A > 1.4 MIN@600 A Add 2% for CF>400 A | |
V ac | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
V dc | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
Ohms | ||
Resolution | 0.1/1/10 | |
Accuracy | 1% ±5 digits | |
Range | 600/6000/60.00 kΩ | |
Capacitance | ||
Resolution | 0.1/1 µF | |
Accuracy | 1% ±4 digits | |
Range | 100.0/1000 µF | |
µA | ||
Resolution | 0.1 µA | |
Accuracy | 1% ±5 digits | |
Range | 200 µA | |
Contact temperature | ||
Resolution | 0.1 C/F | |
Accuracy | 1% ±8 digits | |
Range | -10 to 400 °C (14 °F to 752 °F) | |
Continuity beeper | ||
Beeper volume | 75 dBA nom. 15 cm. from case front | |
On threshold | <=30 Ω | |
Mechanical and General Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | |
Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F) | |
Operating humidity | Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | |
Altitude | Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) | |
Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | |
Weight (meter only) | 419 g (15 oz) | |
Safety | IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 600 V / CAT IV 300 V IEC 61010-2-033: CAT III 600 V / CAT IV 300 V | |
IP Rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |
Todas as marcas comerciais são propriedade dos respectivos proprietários. Smartphone, serviço sem fios e plano de dados não incluídos com a compra. Grátis os primeiros 5 GB de armazenamento. Compatível com iPhone 4s e superior com iOS 8 ou superior, iPad (numa estrutura iPhone num iPad) e Galaxy S4, Nexus 5, HTC One com Android™ 4.4.x ou superior. Apple e o logótipo Apple são marcas registadas da Apple Inc., registada nos EUA e noutros países. App Store é uma marca de serviços da Apple Inc. Google Play é uma marca registada da Google Inc. |
Modelos: Alicate Amperímetro HVAC True-RMS sem fio Fluke 902 FC
O Alicate Amperímetro HVAC 902 FC
inclui:
- Terminais de teste TL75 (1 par)
- Sonda de temperatura DMM integrada 80BK (1)
- 2 pilhas alcalinas AA
- Bolsa de transporte flexível
- Manual do Usuário