Fluke 117 Multimeter and PRV240 Proving Unit Kit

  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • Fluke 117 DMM / PRV240 Proving Unit Kit
  • The PRV240 provides safe verification your test tool is operating properly

์ฃผ์š” ๊ธฐ๋Šฅ

  • True-rms electricianโ€™s digital multimeter with non-contact voltage detection, AutoVolt automatic ac/dc voltage selection
  • Reduces the risk of shock and arc flash by validating the functionality of test tools without placing yourself in a potentially hazardous electrical environment

์ œํ’ˆ ๊ฐœ์š”: Fluke 117 Multimeter and PRV240 Proving Unit Kit

The Fluke 117 multimeter and PRV240 Proving Unit Kit combines a general-purpose electricianโ€™s digital multimeter with a portable, pocket-sized, battery-powered voltage source that provides a safe method to verify that your electrical test tool is operating properly before you conduct any live tests.

Fluke 117 Electricianโ€™s Multimeter

The Fluke 117 Electricians Multimeter includes integrated non-contact voltage detection, AutoVolt and LoZ functions for faster, more accurate readings. It is a compact true-rms meter for demanding applications like commercial buildings, hospitals, and schools.

Fluke 117 key functions

Integrated VoltAlertโ„ข technology for fast, go/no go non-contact voltage detection. Features AutoVolt automatic ac/dc voltage selection

  • Provides low input impedance to help prevent false readings due to ghost voltage
  • Provides Min/Max/Average to record signal fluctuations
  • CAT III 600 V safety rated

PRV240 Proving Unit

The Fluke PRV240 Proving Unit is a portable, pocket-sized, battery-powered voltage source. It is unique in that it sources stable ac and dc voltages for both LoZ and HiZ instruments.

PRV240 Proving Unit key functions

A single LED indicates functionality, making this unit a simple-to-use solution for complying with TBT verification of your test tool. Voltage is sourced through recessed contacts that are activated when test probes are inserted, preventing accidental contact.

  • Includes TPakโ„ข Magnetic Hanging Strap
  • Long battery lifeโ€”5,000 tests per set of four AA batteries

์ œํ’ˆ ์‚ฌ์–‘: Fluke 117 Multimeter and PRV240 Proving Unit Kit

Specifications
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2
IEC 61010-2-033: CAT III 600V
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10ยฐC to +50ยฐC
Storage temperature-40ยฐC to +60ยฐC
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/resolution600.0 mV / 0.1 mV
Accuracyยฑ([% of reading] + [counts]): 0.5% + 2
DC voltsRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracyยฑ([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivoltsยน True RMSRange/resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC voltsยน True RMSRange/resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/resolution600 ฮฉ / 1 ฮฉ
AccuracyBeeper on < 20 ฮฉ, off > 250 ฮฉ detects opens or shorts of 500 ฮผs or longer.
OhmsRange/resolutionOhms Range/resolution 600.0 ฮฉ / 0.1 ฮฉ
6.000 kฮฉ / 0.001 kฮฉ
60.00 kฮฉ / 0.01 kฮฉ
600.0 kฮฉ / 0.1 kฮฉ
6.000 Mฮฉ / 0.001 Mฮฉ
Accuracy0.9% + 1
Range/resolution40.00 Mฮฉ / 0.01 Mฮฉ
Accuracy5% + 2
Diode testRange/resolutionย 
Accuracy0.9% + 2
CapacitanceRange/resolution1000 nF / 1 nF
10.00 ฮผF / 0.01 ฮผF
100.0 ฮผF / 0.1 ฮผF
9999 ฮผF / 1 ฮผF
100 ฮผF to 1000 ฮผF
Accuracy1.9% + 2
Range/resolution> 1000 ฮผF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 ฮผF
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/resolution6.000 A / 0.001 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/resolution6.000 A / 0.001 A 10.00 A / 0.01 A
Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)ยฒRange/resolution99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 Hz
50.00 kHz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
4. Temperature Range/Resolution: -40ยฐF to 752ยฐF / 0.2ยฐF.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Fluke PRV240 Proving Unit

General Specifications
Output voltage240 V ac rms or dcยฑ 10 % โ‰ฅ 1 Mฮฉ
ย LoZ >3 kฮฉ load60 V ac typical
50 V ac rms minimum
LED power indicatorTurns on when output voltage is present
Battery4 AA Alkaline batteries NEDA24 A IEC LR03
Battery life5000 (5-second duration) test cycles with >1 Mฮฉ load, 300 tests minimum with >3 kฮฉ load
Operating temperature-10 ยฐC to +50 ยฐC
Operating humidity0 % to 90 % (0 ยฐC to 35 ยฐC)
0 % to 70 % (35 ยฐC to 55 ยฐC)
Operating altitude2000 m
Dimensions11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2
Weight0.23 kg (8 oz) includes batteries
SafetyIEC61010-1, IEC61010-2-030
WarrantyOne-year
Electromagnetic Compatibility (EMC)IEC 61326-1Portable EM environment; CISPR 11, Group 1, Class A
US (FCC)47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

๋ชจ๋ธ: Fluke 117 Multimeter and PRV240 Proving Unit Kit

FLUKE-117-PRV240
Fluke 117 DMM-PRV240 Proving Unit Kit

๊ตฌ๋งคํ•˜๊ธฐ

Includes:

Electricianโ€™s Multimeter with Non-Contact Voltage

  • 4 mm silicone test lead set
  • 9 volt Alkaline batteryย (installed)
  • Holster
  • User manual

Fluke PRV240 Proving Unit

  • TPAK hanging strap
  • Four AA batteries
  • Instruction sheet
์ฑ„ํŒ…Fluke ๋„์šฐ๋ฏธ
์ฑ„ํŒ… ์ง€์šฐ๊ธฐ