Fluke 117 Multimeter and PRV240 Proving Unit Kit
์ฃผ์ ๊ธฐ๋ฅ
- True-rms electricianโs digital multimeter with non-contact voltage detection, AutoVolt automatic ac/dc voltage selection
- Reduces the risk of shock and arc flash by validating the functionality of test tools without placing yourself in a potentially hazardous electrical environment
์ ํ ๊ฐ์: Fluke 117 Multimeter and PRV240 Proving Unit Kit
The Fluke 117 multimeter and PRV240 Proving Unit Kit combines a general-purpose electricianโs digital multimeter with a portable, pocket-sized, battery-powered voltage source that provides a safe method to verify that your electrical test tool is operating properly before you conduct any live tests.
Fluke 117 Electricianโs Multimeter
The Fluke 117 Electricians Multimeter includes integrated non-contact voltage detection, AutoVolt and LoZ functions for faster, more accurate readings. It is a compact true-rms meter for demanding applications like commercial buildings, hospitals, and schools.
Fluke 117 key functions
Integrated VoltAlertโข technology for fast, go/no go non-contact voltage detection. Features AutoVolt automatic ac/dc voltage selection
- Provides low input impedance to help prevent false readings due to ghost voltage
- Provides Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
PRV240 Proving Unit
The Fluke PRV240 Proving Unit is a portable, pocket-sized, battery-powered voltage source. It is unique in that it sources stable ac and dc voltages for both LoZ and HiZ instruments.
PRV240 Proving Unit key functions
A single LED indicates functionality, making this unit a simple-to-use solution for complying with TBT verification of your test tool. Voltage is sourced through recessed contacts that are activated when test probes are inserted, preventing accidental contact.
- Includes TPakโข Magnetic Hanging Strap
- Long battery lifeโ5,000 tests per set of four AA batteries
์ ํ ์ฌ์: Fluke 117 Multimeter and PRV240 Proving Unit Kit
Specifications | |
---|---|
Maximum voltage between any terminal and earth ground | 600 V |
Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) |
Display | Digital: 6,000 counts, updates 4 per second |
Bar graph | 33 segments, updates 32 per second |
Operating temperature | -10ยฐC to +50ยฐC |
Storage temperature | -40ยฐC to +60ยฐC |
Battery type | 9 volt Alkaline, IEC 6LR61 |
Battery life | 400 hours typical, without backlight |
Accuracy Specifications | ||
---|---|---|
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ยฑ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
Accuracy | ยฑ([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) | |
AC millivoltsยน True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
AC voltsยน True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
Continuity | Range/resolution | 600 ฮฉ / 1 ฮฉ |
Accuracy | Beeper on < 20 ฮฉ, off > 250 ฮฉ detects opens or shorts of 500 ฮผs or longer. | |
Ohms | Range/resolution | Ohms Range/resolution 600.0 ฮฉ / 0.1 ฮฉ 6.000 kฮฉ / 0.001 kฮฉ 60.00 kฮฉ / 0.01 kฮฉ 600.0 kฮฉ / 0.1 kฮฉ 6.000 Mฮฉ / 0.001 Mฮฉ |
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 Mฮฉ / 0.01 Mฮฉ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | ย |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 ฮผF / 0.01 ฮผF 100.0 ฮผF / 0.1 ฮผF 9999 ฮผF / 1 ฮผF 100 ฮผF to 1000 ฮผF |
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 ฮผF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 ฮผF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max | |
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max | |
Hz (V or A input)ยฒ | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40ยฐF to 752ยฐF / 0.2ยฐF. |
Mechanical and General Specifications | |
---|---|
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
Weight | 550 g |
Warranty | 3 years |
Fluke PRV240 Proving Unit
General Specifications | ||
---|---|---|
Output voltage | 240 V ac rms or dc | ยฑ 10 % โฅ 1 Mฮฉ |
ย | LoZ >3 kฮฉ load | 60 V ac typical 50 V ac rms minimum |
LED power indicator | Turns on when output voltage is present | |
Battery | 4 AA Alkaline batteries NEDA | 24 A IEC LR03 |
Battery life | 5000 (5-second duration) test cycles with >1 Mฮฉ load, 300 tests minimum with >3 kฮฉ load | |
Operating temperature | -10 ยฐC to +50 ยฐC | |
Operating humidity | 0 % to 90 % (0 ยฐC to 35 ยฐC) 0 % to 70 % (35 ยฐC to 55 ยฐC) | |
Operating altitude | 2000 m | |
Dimensions | 11.7 cm x 7.4 cm x 2.8 cm (4.6 in x 2.9 in x 1.1 in), Pollution Degree 2 | |
Weight | 0.23 kg (8 oz) includes batteries | |
Safety | IEC61010-1, IEC61010-2-030 | |
Warranty | One-year | |
Electromagnetic Compatibility (EMC) | IEC 61326-1 | Portable EM environment; CISPR 11, Group 1, Class A |
US (FCC) | 47 CFR 15 subpart B, this product is considered an exempt device per clause 15.103 | |
Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. |
๋ชจ๋ธ: Fluke 117 Multimeter and PRV240 Proving Unit Kit
Includes:
Electricianโs Multimeter with Non-Contact Voltage
- 4 mm silicone test lead set
- 9 volt Alkaline batteryย (installed)
- Holster
- User manual
Fluke PRV240 Proving Unit
- TPAK hanging strap
- Four AA batteries
- Instruction sheet