PM500 Pressure Measurement Modules

  • PM500

์ฃผ์š” ๊ธฐ๋Šฅ

For 2271A Industrial Pressure Calibrator and 6270A, 8270A and 8370A Pressure Controller / Calibrators

์ œํ’ˆ ๊ฐœ์š”: PM500 Pressure Measurement Modules

Key features:

  • Highly characterized and linearized silicon pressure sensor provides an economical way of making accurate pressure measurements
  • 0.01% of reading measurement uncertainty from 50% to 100% for most ranges allows for wide workload coverage
  • More than 45 ranges, from low differential pressures up to 20 MPa (3000 psi) to choose from. Your application is covered with this wide flexibility in configuration.

์ œํ’ˆ ์‚ฌ์–‘: PM500 Pressure Measurement Modules

Performance specifications

The performance specifications describe the complete instrumental uncertainty of the Product. The specifications include all relevant error components (linearity, hysteresis, repeatability, resolution, reference standard measurement uncertainty, 1-year drift, and temperature effects). The specifications are provided at a level of confidence of 95ย %, k=2, normally distributed. Precision uncertainty includes linearity, hysteresis, repeatability, resolution, and temperature effects.

PM500 Modules measurement specifications

Specifications are valid from 15 ยฐC to 35 ยฐC.

ModelRange
(SI Units)
Range
(Imperial Units)
Measurement
Mode2
1-Year
Instrumental Uncertainty7
1-Year Zero Instrumental Drift
% FS, RSS with 1-Year Instrumental Uncertainty1
Precision Uncertainty8
PM500-G100K40ย kPa to 100ย kPa0ย psi to 15ย psigauge0.01 or 0.005-0.007 or 0.0035
PM500-G200K40ย kPa to 200ย kPa0ย psi to 30ย psigauge0.01 or 0.005-0.007 or 0.0035
PM500-G250K40ย kPa to 250ย kPa0ย psi to 36ย psigauge0.01 or 0.005-0.007 or 0.0035
PM500-G350K40ย kPa to 350ย kPa0ย psi to 50ย psigauge0.01 or 0.005-0.007 or 0.0035
PM500-G400K40ย kPa to 400ย kPa0ย psi to 60ย psigauge0.01 or 0.005-0.007 or 0.0035
PM500-G600K40ย kPa to 600ย kPa0ย psi to 90ย psigauge0.01 or 0.005-0.007 or 0.0035
PM500-G700K50ย kPa to 700ย kPa0ย psi to 100ย psigauge0.01 or 0.005-0.007 or 0.0035
PM500-BG1M5-0.1ย MPa to 1ย MPa-15ย psi to 150ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG1.4M5-0.1ย MPa to 1.4ย MPa-15ย psi to 200ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG2M5-0.1ย MPa to 2ย MPa-15ย psi to 300ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG2.5M5-0.1ย MPa to 2.5ย MPa-15ย psi to 400ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG3.5M5-0.1ย MPa to 3.5ย MPa-15ย psi to 500ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG4M5-0.1ย MPa to 4ย MPa-15ย psi to 600ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG7M5-0.1ย MPa to 7 MPa-15ย psi to 1000ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG10M5-0.1ย MPa to 10ย MPa-15ย psi to 1500ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG14M5-0.1ย MPa to 14ย MPa-15ย psi to 2000ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BG20M5-0.1ย MPa to 20ย MPa-15ย psi to 3000ย psibi-directional gauge0.01 or 0.005-0.007 or 0.0035
PM500-BA120K3, 660ย kPa to 120ย kPa8ย psi to 17ย psiabsolute0.01ย % of reading0.050.005ย % of reading
PM500-A120K3, 60.08ย kPa to 120ย kPa0.01ย psi to 16ย psiabsolute0.01 or 0.0050.050.007 or 0.0035
PM500-A160K3, 60.08ย kPa to 160ย kPa0.01ย psi to 23ย psiabsolute0.01 or 0.0050.050.007 or 0.0035
PM500-A200K3, 40.08ย kPa to 200ย kPa0.01ย psi to 30ย psiabsolute0.01 or 0.0050.050.007 or 0.0035
PM500- A350Kย 40.08ย kPa to 350ย kPa0.01ย psi to 50ย psiabsolute0.01 or 0.0050.030.007 or 0.0035
PM500- A700Kย 40.08ย kPa to 700ย kPa0.01ย psi to 100ย psiabsolute0.01 or 0.0050.0250.007 or 0.0035
PM500- A1.4Mย 50.035ย MPa to 1.4ย MPa5ย psi to 200ย psiabsolute0.01 or 0.0050.0150.007 or 0.0035
PM500-A2Mย 50.07ย MPa to 2ย MPa10ย psi to 300ย psiabsolute0.01 or 0.0050.0150.007 or 0.0035
ย (% FS + % of reading)ย (% FS + % of reading)
PM500- G2.5Kย 60ย kPa to 2.5ย kPa0ย inH2O to 10ย inH2Ogauge0.03 + 0.02-0.015 + 0.01
PM500-G7Kย 60ย kPa to 7ย kPa0ย inH2O to 30ย inH2Ogauge0.01 + 0.01-0.005 + 0.005
PM500-G14K60ย kPa to 14ย kPa0ย inH2O to 50ย inH2Ogauge0.01 + 0.01-0.005 + 0.005
PM500-G20K60ย kPa to 20ย kPa0ย inH2O to 80ย inH2Ogauge0.01 + 0.01-0.005 + 0.005
PM500-G35K60ย kPa to 35ย kPa0ย psi to 5ย psigauge0.01 + 0.01-0.005 + 0.005
PM500-G70K60ย kPa to 70ย kPa0ย psi to 10ย psigauge0.01 + 0.01-0.005 + 0.005
PM500-NG100K6-100ย kPa to 0ย kPa-15ย psi to 0ย psinegative gauge0.01 + 0.01-0.005 + 0.005
PM500-BG1.4K6-1.4ย kPa to 1.4ย kPa-5ย inH2O to 5ย inH2Obi-directional gauge0.03 + 0.02-0.015 + 0.01
PM500-BG2.5K6-2.5ย kPa to 2.5ย kPa-10ย inH2O to 10ย inH2Obi-directional gauge0.03 + 0.02-0.015 + 0.01
PM500-BG3.5K6-3.5ย kPa to 3.5ย kPa-15ย inH2O to 15ย inH2Obi-directional gauge0.01 + 0.01-0.005 + 0.005
PM500-BG7K6-7ย kPa to 7ย kPa-30ย inH2O to 30ย inH2Obi-directional gauge0.01 + 0.01-0.005 + 0.005
PM500-BG14K6-14ย kPa to 14ย kPa-50ย inH2O to 50ย inH2Obi-directional gauge0.01 + 0.01-0.005 + 0.005
PM500-BG25K6-25ย kPa to 25ย kPa-100ย inH2O to 100ย inH2Obi-directional gauge0.01 + 0.01-0.005 + 0.005
PM500-BG40K6-40ย kPa to 40ย kPa-6ย psi to 6ย psibi-directional gauge0.01 + 0.01-0.005 + 0.005
PM500-BG60K6-60ย kPa to 60ย kPa-9ย psi to 9ย psibi-directional gauge0.01 + 0.01-0.005 + 0.005
ย % FSย % FS
PM500-BG100K4-100ย kPa to 100ย kPa-15ย psi to 15ย psibi-directional gauge0.01-0.005
PM500-BG200K4-100ย kPa to 200ย kPa-15ย psi to 30ย psibi-directional gauge0.01-0.005
PM500-BG250K4-100ย kPa to 250ย kPa-15ย psi to 36ย psibi-directional gauge0.01-0.005
PM500-BG350K4-100ย kPa to 350ย kPa-15ย psi to 50ย psibi-directional gauge0.01-0.005
PM500-BG400K4-100ย kPa to 400ย kPa-15ย psi to 60ย psibi-directional gauge0.01-0.005
PM500-BG700K5-100ย kPa to 700ย kPa-15ย psi to 100ย psibi-directional gauge0.01-0.005

Notes

  1. The 1 Year Instrumental Uncertainty is specified with a zeroing technique in the Operators Manual.ย  If not adhered to the 1 Year Instrumental Uncertainty is:
  2. PM500 gauge or bi-directional mode modules support absolute mode measurement when used with a Barometric Reference Module. Instrumental uncertainty for gauge mode modules used in absolute mode by addition of a barometric reference module is calculated as the uncertainty of the gauge mode module root sum squared with the uncertainty of the barometric reference module. Uncertainty for gauge mode assumes routine zeroing which is default operation mode when used in a chassis.
  3. These modules can be used as barometric reference modules on all chassis.
  4. Compatible with 2271A, 6270A and 8270A
  5. Compatible with 2271A, 6270A, 8270A and 8370A
  6. Compatible with 2271A and 6270A
  7. (% of reading or % FS, whichever is greater) unless otherwise stated
  8. (% of reading or % FS, whichever is greater)

๋ชจ๋ธ: PM500 Pressure Measurement Modules

PM500-G20K
Pressure measurement module 0 to 20 kPa (0 to 80 inh2o) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G35K
Pressure measurement module 0 to 35 kPa (0 to 5 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G70K
Pressure measurement module 0 to 70 kPa (0 to 10 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G100K
Pressure measurement module 0 to 100 kPa (0 to 15 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G200K
Pressure measurement module 0 to 200 kPa (0 to 30 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G250K
Pressure measurement module 0 to 250 kPa (0 to 36 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G350K
Pressure measurement module 0 to 350 kPa (0 to 50 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G400K
Pressure measurement module 0 to 400 kPa (0 to 60 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G600K
Pressure measurement module 0 to 600 kPa (0 to 90 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-G700K
Pressure measurement module 0 to 700 kPa (0 to 100 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG3.5K
Pressure measurement module -3.5 to 3.5 kPa (-15 to 15 inh2o) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG7K
Pressure measurement module -7 to 7 kPa (-30 to 30 inh2o) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG14K
Pressure measurement module -14 to 14 kPa (-50 to 50 inh2o) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG25K
Pressure measurement module -25 to 25 kPa (-100 to 100 inh2o) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG40K
Pressure measurement module -40 to 40 kPa (-6 to 6 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG60K
Pressure measurement module -60 to 60 kPa (-9 to 9 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG100K
Pressure measurement module -100 to 100 kPa (-15 to 15 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG200K
Pressure measurement module -100 to 200 kPa (-15 to 30 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG250K
Pressure measurement module -100 to 250 kPa (-15 to 36 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG350K
Pressure measurement module -100 to 350 kPa (-15 to 50 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG400K
Pressure measurement module -100 to 400 kPa (-15 to 60 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG700K
Pressure measurement module -100 to 700 kPa (-15 to 100 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG1M
Pressure measurement module -0.1 to 1 ย mpa (-15 to 150 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG1.4M
Pressure measurement module -0.1 to 1.4 mpa (-15 to 200 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG2M
Pressure measurement module -0.1 to 2 mpa (-15 to 300 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG2.5M
Pressure measurement module -0.1 to 2.5 mpa (-15 to 400 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG3.5M
Pressure measurement module -0.1 to 3.5 mpa (-15 to 500 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG4M
Pressure measurement module -0.1 to 4 mpa (-15 to 600 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG7M
Pressure measurement module -0.1 to 7 mpa (-15 to 1000 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG10M
Pressure measurement module -0.1 to 10 mpa (-15 to 1500 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG14M
Pressure measurement module -0.1 to 14 mpa (-15 to 2000 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-BG20M
Pressure measurement module -0.1 to 20 mpa (-15 to 3000 psi) gauge

๊ตฌ๋งคํ•˜๊ธฐ
PM500-A120K
Pressure measurement module 120 kPa (16 psi) absolute

๊ตฌ๋งคํ•˜๊ธฐ
PM500-A160K
Pressure measurement module 160 kPa (23 psi) absolute

๊ตฌ๋งคํ•˜๊ธฐ
PM500-A200K
Pressure measurement module 200 kPa (30 psi) absolute

๊ตฌ๋งคํ•˜๊ธฐ
PM500-A350K
Pressure measurement module 350 kPa (50 psi) absolute

๊ตฌ๋งคํ•˜๊ธฐ
PM500-A700K
Pressure measurement module 700 kPa (100 psi) absolute

๊ตฌ๋งคํ•˜๊ธฐ
PM500-A1.4M
Pressure measurement module 1.4 mpa (200 psi) absolute

๊ตฌ๋งคํ•˜๊ธฐ
PM500-A2M
Pressure measurement module 2 mpa (300 psi) absolute

๊ตฌ๋งคํ•˜๊ธฐ