한국어

모터, 드라이브, 펌프, 압축기

Resources to enhance your preventive maintenance and motor reliability programs. Explore solutions to reduce unplanned downtime, maximize uptime and increase speed to resolution.

모터 및 드라이브

비디오

주문형 웨비나

모터 및 드라이브

  • 지금 보기
    Motor and drive series session 1 - Motor and drive principles
  • 지금 보기
    Motor and drive series session 2 - Input power measurements
  • 지금 보기
    Motor and drive series session 3 - Motor electrical measurements

모든 모터, 드라이브, 펌프 및 압축기 문서

문서

Motor analysis should be a part of your maintenance routine

Discover how the Fluke 438-II Power Quality and Motor Analyzer can play a key role in maintenance programs.

문서

Fluke MDA-550 모터 드라이브 분석기로 모터 샤프트 전압 방전 측정

이 응용 지침서에서는 Fluke MDA-550 모터 드라이브 분석기와 샤프트 전압 프로브를 사용하여 모터 샤프트 전압 방전 이벤트를 측정하는 방법을 설명합니다.

문서

Fluke MDA-550 모터 드라이브 분석기를 통해 모터 드라이브 문제 해결 복잡성 감소

문서

Fluke electrical analysis tool verified to measure torque without halting motor operation

문서

How to inspect a motor with a thermal imager

Seeing a motor’s heat signature under normal operating conditions—with at least 40 % of design load—can tell you a lot about its condition.

문서

Using infrared cameras for preventive maintenance

Information on the role of thermal imagers in preventive maintenance programs, including cost savings, return on investment (ROI), and the inspection process. Included are common examples of infrared camera applications.

문서

모터 드라이브 효율과 성능을 해석하는 5개 주요 테스트 지점

모터 드라이브는 기계 장비 부하를 구동하는 모터에 적합하게 모터 토크와 속도를 제어하는 가변 전압으로 주 AC 전원 공급장치의 정전압을 변환하는 유비쿼터스 기술입니다.

문서

Transients and voltage unbalance

The electrical power issues that most frequently affect industrial plants include voltage sags and swells, harmonics, transients, and voltage and current unbalance.

문서

See how the 438-II Motor Analyzer is building an underwater fan club

Watch the video to see how the Point Defiance Zoo and Aquarium uses the Fluke 438-ii power quality analyzer and motor analyzer to reduce water and energy use.

문서

A motor braking manufacturing plant steps up to proactive maintenance

Bob Despres of Jacobs Vehicle Systems® in Bloomfield, CT shares how he stepped up the motor maintenance program to be more proactive.

문서

Keep those motors running: electric motor maintenance preventing downtime

문서

13 common causes of motor failure

This article demonstrates how to detect the 13 most common causes of winding insulation and bearing failure in advance.

문서

How to measure output voltage from a VFD to a motor

How to measure output voltage from a VFD to a motor

문서

새로운 Fluke 모터 드라이브 분석기로 바쁜 엘리베이터 전자 장치 기술자의 시간 절약

Fluke MDA-550 모터 드라이브 분석기에서는 시간을 절약하고 엘리베이터 모드 드라이브의 문제 해결을 간소화할 수 있는 적절한 설정을 위한 명확한 다이어그램, 미리 정의된 테스트 절차 및 단계별 지침을 제공합니다.

문서

Troubleshooting Premature Motor Failures

Troubleshooting premature motor failures

문서

Managing VFD Voltage with a Shaft Grounding Kit

Managing VFD voltage with a shaft grounding kit to detect shaft currents and eliminate downtime for customers, with a Fluke ScopeMeter™ oscilloscope

문서

Maximizing VFD and UPS performance

Monitoring power quality parameters in a variable frequency drive or uninterruptible power supply, can help to maximize performance. Find out how to determine what power quality parameters to measure and when as well as other associated issues such as harmonic currents.

문서

Multimeter measurements on adjustable speed drives utilizing the new Fluke 87V DMM

In the past, motor repair meant dealing with traditional three-phase motor failures that were largely the result of water, dust, grease, failed bearings, misaligned motor shafts, or just plain old age. But motor repair has changed in a big way with the introduction of electronically controlled motors, more commonly referred to as adjustable speed drives (ASDs).

문서

Preventing machine failure by detecting the first signs of trouble

Preventing machine failure by detecting the first signs of trouble

문서

Don't run it backwards

There's an old saying that the first time you hook up a three-phase motor it will run backwards. If you're lucky, it will only make you look foolish. If you're not, it could severely damage expensive equipment and cost you or your employer substantial money.

문서

Using thermal imaging to monitor motors and gearboxes

Predictive maintenance (PdM) programs monitor equipment condition, with the goal of identifying problems in advance and avoiding equipment failure. One powerful tool for monitoring rotating equipment is thermal imaging.

문서

How to troubleshoot motors and drives, starting at the inputs

Here we look closely at the first segment in a typical three-phase motor and drive system: from the mains supply at the drive input to the drive itself, concentrating on input measurements. This application note maps common problems to the measurements used to diagnose them . We show you what tools to use for a given situation and how to apply them to a problem, to enable you to troubleshoot more quickly and accurately.

문서

Identifying and solving common motor and drive problems

Troubleshooting motor and drive problems such as single-phasing (losing one of the phase voltages) and flashover currents to outer bearings.

문서

Four must-have measurement practices for the mechanical maintenance team

Four must-have measurement practices for the mechanical maintenance team: thermal, vibration, insulation, electrical

문서

Fluke 1587 Insulation Multimeter helps keep 1950s motors and generators running into the 21st century

MetalTech produces steel sheets. Maintenance technicians use the Fluke 1587 Insulation Multimeter to troubleshoot and maintain the equipment.

문서

Top causes of single-phase motor malfunctions

Most problems with single-phase motors involve the centrifugal switch, thermal switch, or capacitor(s). If the problem is in the centrifugal switch, thermal switch, or capacitor, the motor is usually serviced and repaired. However, if the motor is more than 10 years old and less than 1 HP, the motor is usually replaced. If the motor is less than 1/8 HP, it is almost always replaced.