Fluke Ti300 a3001 FC iFlex® Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 114.53ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke Ti300 a3001 FC iFlex® Kit
  • Fluke Ti300 a3001 FC iFlex® Kit
  • Fluke Ti300 a3001 FC iFlex® Kit
  • Fluke Ti300 a3001 FC iFlex® Kit
Discontinued

Key features

The Ti300 offers:

  • Consistently in-focus images with the exclusive LaserSharp® Auto Focus system
  • Precisely blended visual and infrared images with the industry's only IR-Fusion® technology with AutoBlend™ mode
  • Fluke Connect® compatible - the largest network for wirelessly enabled tools
  • Faster communication with wireless image transfer directly to your PC, Apple® iPhone® or iPad®
  • Ruggedized high resolution 640 x 480 capacitive touch screen for quick menu navigation
  • Capture additional digital images to show location or additional site details with IR-PhotoNotes™ Annotation System
  • More advanced display output options to get the details via streaming video to PC or high definition monitor (USB and HDMI)
  • Voice recording and annotation gets additional details saved with the image file
  • Optional interchangeable lenses for greater flexibility in additional applications
  • Rechargeable, field replaceable smart batteries with LED display to show charge levels for excellent field flexibility
  • 5 MP industrial-performance digital camera for high definition image quality
  • Included SmartView® and SmartView Mobile App Analysis and Reporting Software

The 3000 FC Wireless Multimeter offers:

  • AC and DC voltage measurements to 1000 V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:

  • One (1) true-RMS flexible current meter
  • One (1) iFlex i2500-10 flexible current probe
  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Magnetic hanging strap
This product is discontinued or reclassified

Product overview: Fluke Ti300 a3001 FC iFlex® Kit

The Ti300 a3001 FC iFlex® Kit is a robust industrial kit that helps you quickly and accurately troubleshoot with ease directly from the field. Connect the a3001 FC iFlex® AC Wireless Current Module to your test point and view the results up to 20 meters away on your 3000 FC DMM. The a3001 FC iFlex® module allows you to measure around tight, awkward spaces and/ or sizes and makes wire access easier. Save and share inspection data from the field with your team - anytime, from anywhere only with ShareLive™ video call and get the answers and approvals you need the first time, in-real time.

The Ti300 is one of only three thermal cameras in the Fluke portfolio equipped with LaserSharp® Auto Focus for consistently in-focus images. Every. Single. Time. Without an in-focus image, temperature measurements may be off by as much as 20 degrees making is much easier to miss a problem. LaserSharp® Auto Focus tells you exactly where you are focusing. It uses a laser to calculate the distance to your target before it focuses. Place the red laser dot on the equipment you are inspecting, then pull and release the trigger for a perfect in-focus image. Uptime or downtime. Your Results Matter.

Specifications: Fluke Ti300 a3001 FC iFlex® Kit

Fluke Ti300 Infrared Camera

Detailed Specifications
Temperature
Temperature measurement range (not calibrated below -10°C)-20°C to +650°C
(-4°F to +1202°F)
Temperature measurement accuracy±2°C or 2% (at 25°C nominal, whichever is greater)
On-screen emissivity correctionYes (by number and table)
On-screen reflected background temperature compensationYes
On-screen transmission correctionYes
Imaging Performance
Image capture frequency60 Hz refresh rate
Detector typeFocal Plane Array, uncooled microbolometer, 240 x 180 pixels
Thermal sensitivity (NETD)≤ 0.05°C at 30°C target temp (50 mK)
Total pixels43,200
Infrared spectral band7.5 μm to 14 μm (long wave)
Visual (visible light) cameraIndustrial performance 5.0 megapixel
Standard Infrared Lens Type
Field of view24° x 17°
Spatial resolution (IFOV)1.75 mRad
Minimum focus distance15 cm (approx. 6 in)
Optional Telephoto Infrared Lens Type
Field of view12° x 9°
Spatial resolution (IFOV)0.87 mRad
Minimum focus distance45 cm (approx. 18 in)
Optional Wide-Angle Infrared Lens Type
Field of view46° x 34°
Spatial resolution (IFOV)3.49 mRad
Minimum focus distance15 cm (approx. 6 in)
Focus Mechanism
LaserSharp® Auto Focus systemYes
Advanced manual focusYes
Image Presentation
Palettes
StandardIronbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra Contrast™Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
Level and spanSmooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual and auto modesYes
Fast auto-rescale in manual modeYes
Minimum span (in manual mode)2.0°C (3.6°F)
Minimum span (in auto mode)3.0°C (5.4°F)
IR-Fusion® Information
Picture-in-Picture (PIP)Yes
Full screen infraredYes
AutoBlend™ modeYes
Color alarms (temperature alarms)High-temperature , low-temperature, and isotherm (user-selectable)
Image Capture and Data Storage
Image capture, review, save mechanismOne-handed image capture, review, and save capability
Storage mediumMicro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection
File formatsNon-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp and jpg) files
Export file formats w/SmartView® softwareBMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Memory reviewThumbnail view navigation and review selection
Other Time-Saving and Productivity Features
Voice annotation60 seconds maximum recording time per image; reviewable playback on imager
IR-PhotoNotes™Yes
WiFi connectivityYes, to PC, iPhone®, iPad® and WiFi to LAN1
Text annotation1Yes
Video recording1Standard and radiometric
Streaming videoVia USB to PC and HDMI to HDMI compatible screen
Fluke Connect compatibleYes (where available)
Auto capture (temperature and interval)1Yes
Remote control and operation (for special and advanced applications)No
General Specifications
Operating temperature-10°C to +50°C (14°F to 122°F)
Storage temperature-20°C to +50°C (-4°F to 122°F) without batteries
Relative humidity10% to 95% non-condensing
Ruggedized touchscreen display (capacitive)8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight
Controls and adjustmentsUser selectable temperature scale (°C / °F)
Language selection
Time/Date set
Emissivity selection
Reflected background temperature compensation
Transmission correction
User selectable hot spot and cold spot, and center point on the image
Expandable-contractable Measurement Box with MIN-AVG-MAX temp
Color alarms
User selectable backlight setting graphical information display preference
Graphical information display preference
SoftwareSmartView® and SmartView Mobile App - full analysis and reporting software included
BatteriesTwo lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models
Battery lifeFour+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage)
Battery charge time2.5 hours to full charge
AC battery chargingTwo-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter.
AC operationAC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included.
Power savingUser selectable sleep and power off modes
Safety standardsUL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010)
Electromagnetic compatibilityEN 61326-1:2006 IEC 61326-1:2005
C TickIEC/EN 61326-1
US FCCCFR 47, Part 15 Subpart B Class B
Vibration0.03 g2/Hz (3.8 grms), 2.5 g IEC 68-2-6
Shock25 g, IEC 68-2-29
DropEngineered to withstand 2 meter (6.5 feet) with standard lens
Size (H x W x L)27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in)
Weight (battery included)1.04 Kg (2.3 lb)
Enclosure ratingIP54 (protected against dust, limited ingress; protection against water spray from all directions)
WarrantyTwo-years (standard), extended warranties are available.
Recommended calibration cycleTwo-years (assumes normal operation and normal aging)
Supported languagesCzech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
1. Coming soon via firmware update. Users notified via SmartView software when available.
 

Fluke 3000 FC Series Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0% to 90%. Accuracy specifications take the form of ±([% of Reading] + [Number of least significant digits]).

Detailed Specifications
AC Voltage
Range ¹ / Resolution600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 445 Hz to 500 Hz1.0% + 3
500 Hz to 1 kHz2.0% + 3
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mVRange / Resolution600.0 mV / 0.1 mV
Accuracy0.09% + 2
VRange / Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy0.09% + 2
0.15% + 2
)))Range / Resolution600 Ω / 1 Ω
AccuracyMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
ΩRange / Resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy0.5% + 2
0.5% + 1
1.5% + 3
Diode testRange / Resolution2.000 V / 0.001 V
Accuracy1% + 2
µFRange / Resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range 1 / Resolution60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy1.5% + 3
mA DC 2Range 1 / Resolution60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy0.5% + 3
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy 10.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance)Normal mode rejection
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 Vrms> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scale voltageTypical short circuit current
To 6 MΩ50 MΩTypical short circuit current
1100 Vrms< 2.7 VDC< 0.7 VDC< 0.9 VDC< 350 mA
1100 Vrms< 2.7 VDC2.000 VDC< 1.1 mA
mA Function
Overload protectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functionsThe specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 VDC or AC rms
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate4/sec
Volts, amps, ohms6000 counts
Frequency10,000 counts
Capacitance1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall, or steel electrical enclosureUp to 3.5 m
TemperatureOperating-10°C to 50°C
Storage-40°C to 60°C
Temperature coefficient0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
AltitudeOperating2,000 m
Storage12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution Degree2
Size (H x W x L)4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools
 

Fluke a3001 FC Wireless iFlex AC Current Module

Specifications
Range0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3% ±5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
add 2% for C.F. > 2
LCD w/backlight3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructedUp to 20 m
Obstructed, sheetrock wallUp to 6.5 m
Obstructed, concrete wall or steel electrical enclosureUp to 3.5 m
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Temperature coefficientAdd 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity90% at 35°C
75% at 40°C
45% at 50°C
AltitudeOperating2,000 m
Storage12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) ratingIP42
Pollution Degree2
Jaw opening25.4 cm (10 in) coil
Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years
Not compatible with Fluke CNX test tools

Models: Fluke Ti300 a3001 FC iFlex® Kit

FLK-Ti300/FCA Kit
Fluke Ti300 a3001 FC iFlex® Kit

Includes:

Ti300 Infrared Camera

  • AC power supply and battery pack charger (including mains adapters)
  • Two, rugged lithium ion smart battery packs
  • Micro SD memory card
  • USB cable
  • HDMI video cable
  • SmartView® software available via free download
  • Rugged, hard carrying case
  • Soft transport bag
  • Adjustable hand strap
  • Warranty registration card
  • International adapter set (9 Hz only)

3000 FC Series Wireless Multimeter

  • Fluke 3000 FC Wireless Digital Multimeter with three (3) AA batteries (installed)
  • One (1) a3001 FC Module with two (2) AA batteries (installed)
  • One (1) iFlex 10"" coil
  • One (1) magnet/strap
  • TL175 Test Leads (1 pair)
  • AC175 Alligator Clips (1 pair)
  • C3003 3-compartment soft case
  • Information pack
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 124.97ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.13ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.