Fluke 28 II Rugged Digital Multimeter
Model#: Fluke 28 II
Fluke 28 II Rugged Digital Multimeter is rated out of 5 by 15.
Compare products: digital multimeters
- Fluke 87V MAX True-rms Digital Multimeter
- Fluke 87V Industrial Multimeter
- Fluke 279 FC True-rms Thermal Multimeter
- Fluke 179 True-RMS Digital Multimeter
- Fluke 117 Electrician's Multimeter with Non-Contact Voltage
- Fluke 115 Field Technicians Digital Multimeter
- Fluke 177 True-RMS Digital Multimeter
- Fluke 289 True-RMS Data Logging Multimeter
- Fluke 116 Digital HVAC Multimeter
- Fluke 287 True-RMS Electronics Logging Multimeter
- Fluke 3000 FC Series Wireless Multimeter
- Fluke 114 Electrical Multimeter
- Fluke 113 Digital Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
- Fluke 175 True-RMS Digital Multimeter
- Fluke 27 II Rugged Digital Multimeter
- Fluke 88V Deluxe Automotive Multimeter
- Fluke 77 IV Digital Multimeter
- Fluke v3000 FC Wireless AC Voltage Module
- Fluke v3001 FC Wireless DC Voltage Module
- Fluke 107 Palm-sized, CAT III Digital Multimeter
- Fluke 1587 FC Insulation Multimeter
Key features
- IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
- Designed to withstand 3 meter drop (with holster)
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
- MSHA approval
- Limited lifetime warranty
Product overview: Fluke 28 II Rugged Digital Multimeter
The standard for rugged
The Fluke 28 II digital multimeter defines the standard for operating in harsh conditions with the features and accuracy to troubleshoot most electrical problems. The meter offers an IP 67 (waterproof and dustproof) rating, MSHA approvals, extended operating temperature range of -15 °C to +55 °C (5 °F to 131 °F, -40 °C for up to 20 minutes) and 95% humidity, and has been designed and tested to withstand a 3 m (10 ft) drop. The Fluke 28 II Rigged Digital Multimeter is built to work in the toughest environments.
Other key capabilities
- Measure up to 1000 V AC and DC
- Measure up to 10 A (20 A for 30 seconds)
- 10,000 μF capacitance range
- Frequency to 200 kHz
- Extended AC voltage bandwidth– 15 Hz to 20 kHz
- Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
- Resistance, continuity and diode test
- Min/Max and average recording to capture variations automatically
- Peak min-max
- Hi resolution 20,000 count display mode
- True-rms ac voltage and current for accurate measurements on non linear signals
- Backlit keypad buttons allow for easy visibility in low-lit areas
- Large display digits and 2 level bright white backlight for increased visibility
- Reversible holster for added protection when not in use
- Withstands hazardous 8,000 volt spikes caused by load switching and faults on industrial circuits and complies with second edition IEC and ANSI electrical safety standards
- Long battery life (800 hours)
- Relative mode to remove test lead resistance from low ohms measurements
- Auto and manual ranging for maximum flexibility
- Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks
What's in the box:
- Fluke 28 II Rugged Digital Multimeter
- (1 pair) TL75 test leads
- (1 pair) AC175 alligator clips
- 80BK-A type-K thermocouple leads
- Quick reference guide
Specifications: Fluke 28 II Rugged Digital Multimeter
| Accuracy Specifications | ||
| DC voltage | Range | 0.1 mV to 1000 V |
| Accuracy | 0.05% + 1 | |
| AC voltage | Range | 0.1 mV to 1000 V |
| Accuracy | 0.7% + 4 | |
| DC current | Range | 0.1 μA to 10 A |
| Accuracy | 0.2% + 4 | |
| AC current | Range | 0.1 μA to 10 A |
| Accuracy | 1.0% + 2 | |
| Resistance | Range | 0.1 Ω to 50 MΩ |
| Display counts | 6000 | |
| Capacitance | 1 nF to 9999 μF | |
| Frequency | 0.5 Hz to 199.99 kHz | |
| Temperature | -200°C to +1090°C | |
| Low pass filter (Measurement on VSD’s) | Yes | |
| Compliance | CAT IV 600 V , CAT III 1000 V | |
| IP rating | IP 67 | |
| Power | Three AA batteries | |
| Battery life | 800 hours | |
| General Specifications | ||
| Display | Bar graph/backlight | Yes/Yes |
| Data storage | Peak transient capture | 250 μS |
| Min/Max/Avg | Yes | |
| Reading hold | Yes | |
| Other features | Relative readings (zero) | Yes |
| Battery type | Three AA batteries | |
| Warranty and protection | Safety rating | CAT IV 600 V/CAT III 1000 V |
| Mine safety | MSHA Approved | |
| External protection | Rubber holster | |
| Drop test | 10 feet drop test | |
| Dustproof/waterproof | Yes, IP 67 rated | |
| Warranty | Limited lifetime | |
| Size (H x W x L) with holster | 6.35 x 10.0 x 19.81 cm (2.5 x 3.93 x 7.8 in) | |
| Weight with holster | 698.5 g (1.54 lb) | |
Models: Fluke 28 II Rugged Digital Multimeter
Fluke 28 II
Fluke 28 II Rugged Digital Multimeter
- TL75 test leads
- AC175 alligator clips
- 80BK-A type-K thermocouple leads
Rated 5 out of 5 by Dtbeltz from Great and incredibly tough. I have owned it for about a year. And I have had other name brands. This one is reliable good on batteries. Has a incredible bright display. Use it almost daily l.
Date published: 2016-12-07
Rated 5 out of 5 by Patrick from GREAT METER Have had the Fluke 28II for over a 2 years. What a Great Meter. Had a problem from the start when you tried to use the beeper in the continuity mode, the battery would be displayed on screen. Saying the battery was low. Other that the meter worked great. Just sent in they fixed that problem and calibrated the meter. What a GREAT PRODUCT AND COMPANY. Thank you Fluke
Date published: 2013-01-21
Rated 5 out of 5 by fluke28 from I love this meter with all of the specs I love this meter with all of the specs and very tough i had seen reveiws on the meter i have had now for just over a month and relised it has a fault, the meter tells me the batterys are flat when there not as it will not let me use the back light or beep. Ok so this happens the bad point is fluke wont get back to my boss about replacment not repair as it was faulty from day one "life time warranty" WELL ?
Date published: 2012-09-12
Rated 5 out of 5 by AJ430 from KLUTZ! I was thinking of buying an 87V but decided to try the mil-spec "heavy duty" version of the 87V; the FLUKE 28||. Mind you this was only the second VOM meter I ever purchased & the most expensive thus far, so I was afraid of even getting it dirty. While performing maintenance on a commercial building I had an incident. I didn't have it for a week before the klutz in me took over & the meter did a peter-pan out of my grasp, bounced off the roof access ladder & in my horror I watched helplessly as my FLUKE 28|| plummeted in slow motion thirty feet before smacking into solid concrete. After finding no exterior damage I turned it on & to my astonishment it worked! The only thing I can find wrong with it is the loud beeper is silent, I have the T5-600 if I really need to make some continuity noise. I know I should have the meter properly calibrated to make sure it's still accurate but I tested it on some known electrical effects & it's accurate enough for me right now. as for the beeper... I don't miss it. If it was any other meter besides the FLUKE 28||, I assure you it would've involved a broom & dustpan!
Date published: 2012-08-09
Rated 4 out of 5 by Radek from Battery issue As is written below - the same issue:
“Have had the Fluke 28II for over a 2 years. Had a problem from the start when you tried to use the beeper in the continuity mode, the battery would be displayed on screen. Saying the battery was low.”
You need to remove the bottom hood (6 screws battery hood and another six screws for bottom DMM hood). Then you can see the beeper on the opposite side of display. You need only add some resistor (47-56R) in serial to the beeper. For fix you must remove the beeper – there are connected 3pin together and one pin separately. You must use campton tape between the PAD on PCB, and then connect it through resistor. That’s easy and fully working – of course the volume comes down a little, but I doesn’t matter and battery issue disappear.
Radek
Date published: 2013-07-22
Rated 2 out of 5 by CANUSER from Fluke 28II has LCD Issues The LCD screen on my 28II meter has never been great.
All of the photos on the website show the meter's numerical displays to be dark and crisp. However, in reality (at least with my meter), in DC Voltmeter mode, the V and DC in the upper right of the screen are barely visible. In AC Voltmeter mode, the V is barely visible, but the AC is dark and crisp. In Ohmmeter mode, the Ohm Symbol and the k for kiloohm are barely visible. The M for megaohm, however, is dark and crisp. The bar graph is dark and crisp, Manual is dark and crisp, but Auto is barely visible. In temperature mode, the degrees C is dark and crisp, but the degrees F is barely visible. The middle segments of the 7-segment numerical displays are often barely visible as well, and the other segments are variable in their display.
Date published: 2022-11-23
Rated 2 out of 5 by mule1812 from Great meter, useless battery design I purchased this unit approximately one year ago it has performed flawlessly and reliably.
Working in remote areas I thought it prudent to read the manual for battery replacement. Manual states that you require AA batteries and Phillips head screwdriver, imagine my surprise when the batteries fail and I go to replace them and find that the screws in the manual referred to as Phillips head are a specialised type screw which no sane person would carry in their toolbox. Being 150km from the nearest town with a hardware store that was the end off the days work being unable to test the solar setup.
Getting home I find in my toolkit a torque head that fits this unusual screw, opening the compartment I find a battery holder that Quasimodo on a sad day would have designed. Seriously if that’s the best you could come up with you need to fire the person responsible and hire someone from kindergarten.
Date published: 2020-06-11