| Electrical Characteristics | |
| Current ranges | 60 A / 600 A / 6000 A AC rms | 
| Output sensitivity (AC coupled) | 50 mV /5 mV / 0.5 mV per A | 
| Load impedance | 100 kOhm minimum | 
| Accuracy (at +25°C) | ±1% of range (45 – 65 Hz) | 
| Linearity (10% to 100% of range) | ±0.2% of reading | 
| Noise | 8 mV AC rms (60 A) | 
| 2 mV AC rms (600/6000 A) | |
| Frequency range | 10 Hz to 50 kHz (-3 dB) | 
| Phase error | < ±1° (45 – 65 Hz) | 
| ±10° (at 20 kHz) | |
| Position sensitivity (with cable > 25 mm from the coupling) | 
 Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.  | 
| External field (with cable > 200 mm from the head) | ±1% of range | 
| Power supply | 2 x AA MN 1500 LR6 alkaline | 
| 400 Hours, low battery indicator or dedicated ext power supply | |
| Temperature coefficient | ±0.08% of reading per ° C | 
| Working voltage (see Safety Standards section) | 600 V AC rms or DC | 
| General Characteristics | |
| Head cable length (double insulated) | 610 mm (24 in) I6000s Flex-24 | 
| 915 mm (36 in) I6000s Flex-36 | |
| Head cable diameter | 14.3 mm | 
| Head bend radius | 38.1 mm | 
| Cable length (head to electronics) | 2 m | 
| Output connection | 0.5 m cable terminated with safety BNC connector | 
| Supplied with 4 mm safety plug adaptor | |
| Operating temperature range | -20 to +90°C (head) | 
| -20 to +85°C (electronics) | |
| Storage temperature range | -40 to +105°C (head) | 
| -20 to +85°C (electronics) | |
| Operating humidity | 15% to 85% (non condensing) | 
| Weight | 180 g (head), 190 g (electronics) | 
| Safety Standards | |
| BS EN 61010 | 1: 2001 | 
| BS EN 61010 | 2-032: 2002 | 
| BS EN 61010 | 031: 2002 | 
| 600 V rms, Category III, Pollution degree 2 | |
| EMC standards | BS EN 61326: 1998 +A1, A2, and A3 | 
| Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz | |