English

Fluke ii910 Precision Acoustic Imager

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.8ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke ii910 Precision Acoustic Imager
  • Fluke ii910 Precision Acoustic Imager
  • ii910 Precision Acoustic Imager

Key features

  • New: MecQ™ mechanical scanning
  • PDQ Mode™: Capture and analyze partial discharge
    On device partial Discharge classification & PRPD plot
  • LeakQ™: On device leak rate and cost calculation
    Online CO2 emission reporting
  • Reduce outages and increase uptime
  • Cut costs and save energy everyday by finding and fixing PD

Product overview: Fluke ii910 Precision Acoustic Imager

Industrial imaging virtual demo

Finally, an easy way to detect, locate and analyze partial discharge in one tool

Tired of spending too much time detecting partial discharge? Introducing the ii910 Precision Acoustic Imager, engineered to locate partial discharge, corona discharge as well as gas and vacuum leaks. The ii910 acoustic imaging camera's groundbreaking technology is a cost efficient, safe, effective, and comfortable tool for teams who inspect and maintain power distribution and industrial high voltage equipment.

The invisible threat….now you can see

Partial discharge is a serious issue that teams monitor everyday. Whether you are scanning insulators, transformers, switch gears or high voltage powerlines you need to be sure that you spot a problem quickly and early. Partial discharge that goes unchecked can cause blackouts, fires, explosions, or death from arc flashes. In addition to the danger that this can pose to the environment and human lives, it also has a very steep price tag. Having equipment go down can cost millions of dollars per hour and studies have shown that a single data center outage could cost as much as $8,851 per minute. On top of this, the Department of Energy estimated that outages cost the US economy $150 billion annually.

Key areas to scan for PD

  • Insulators
  • Transformers
  • High voltage powerlines
  • Switch gears
  • Arrestors
  • Busbars
  • High voltage coils
  • Breakers
  • Capacitors
 

Do it fast, Do it safe

The ii910 is the all-in-one tool you have been looking for when it comes to all your leak, PD, and mechanical issues. Everything you need is right at your fingertips. Quickly scan the area or environment and get all the pictures and videos you need with the simple one-button capture and large 7” touchscreen LCD. No additional tools or equipment needed. With no cumbersome secondary cables or devices needed, you have full mobility and greater flexibility to swap between detecting leak/PD/mechanical issues and fixing the issues.

Fluke safety you can trust with performance you value

The Fluke ii910 Precision Acoustic Imager is the perfect tool for high voltage electricians, electrical test engineers, and grid maintenance teams that are constantly inspecting and maintaining power distribution and industrial high voltage equipment. The ii910 provides a safe quick and easy way to detect and locate partial discharge in order to maintain high voltage equipment and prevent catastrophic events. With the SoundSight™ technology the ii910 translates the sounds that it hears into a visual representation so that you can quickly locate problem areas. The higher frequency capability of the ii910 allows for earlier detection to facilitate early maintenance planning that is why the ii910 has a frequency range of 2-100Khz.

Find and fix before flash

Partial discharge can cause a number of very serious and expensive problems from catastrophic equipment failure to lethal arc flashes. The only way to stop this from happening is to inspect and maintain the equipment properly. The ii910 Precision Acoustic Imager is built to make finding PD much more comfortable faster and easy. Gone are the days of wearing headphones and listening for very faint sounds or squinting at a small screen to locate issues. Everything you will need to locate issues from a large distance is in the ii910, no cords or other accessories hanging down and getting tangled. Simply pick it up, turn it on and start locating issues.

Safety you expect with the rugged product you trust

Safety is key when working on high voltage equipment and here at Fluke safety is all that matters, everything else is just a bonus. Due to the combination of specific microphone positions and a sophisticated algorithm the ii910 Precision Acoustic Imager can detect PD and Corona Discharge from 120 meters away. This means that you can stay even further than the required distance away while still being effective and efficient at finding all of the problem areas. With no external cords or dangling accessories the ii910 ensures that you wont get tangled up in any equipment as you do your rounds. In addition with the acoustic imaging technology being able to pick up reflections of sounds you don’t even need to have direct line of sight to locate a problem. This means you can locate PD without ever opening a cabinet.

Find it quickly, find it easily with no training

The ii910 is truly designed so that anyone can use it with little to no training. Tear up those certifications because you don’t need one to operate this tool. Simply turn on the ii910 with one button select your frequency range (or let the tool do that for you) and start scanning around immediately looking for PD, leaks, or mechanical areas of interest. Once you find a concerning image of a sound you can take a video or a photo to be used later after you have added any text annotation. If you want to know more details about a specific leak, PD, or potential mechanical issue, switch into PDQ, LeakQ, or MecQ mode.

LeakQ online reporting tool

  • Local PC installed application
  • No Leak Type selection (should be included at time of capturing the measurement)
  • Offers customization of reporting template

LeakQ report

Fluke PDQ Mode™ Reporting Tool with Acoustic Imaging

  • Web (cloud) based solution
  • Standardized reporting template
  • Leak Type selection per capture

PDQ report

What's in the box:

  • ii910 Precision Acoustic Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

Specifications: Fluke ii910 Precision Acoustic Imager

Sensors
Frequency band2 kHz to 100 kHz
Detection range0.5 to > 120 meters (1.6 to > 393 feet)*
Field of View63 ° ± 5 °
Nominal frame rate25 FPS
*Depending on ambient conditions
Built-in digital camera (visible light)
Field of View (FOV)63 ° ± 5 °
FocusFixed lens
Zoom3 x Digital Zoom
Resolution5 MP
Display
Size7" LCD with backlight, under-sunlight readable
Resolution1280 x 800 (1,024,000 pixels)
TouchscreenCapacitive
Acoustic imageYes, SoundMap™ image
Image storage
Storage capacity20GB (>5000 pictures / >999 videos)
Image formatBlended visual and SoundMap™.JPG or .PNG
Video formatBlended visual and SoundMap™.MP4
Video lengthUp to 5 minutes
Digital exportUSB-C for data transfer
Acoustic Measurements
Measurement range (typical)12.1 to 114.6dB SPL (±1dB SPL 2kHz)
4.4 to 101.2dB SPL (±2dB SPL 19kHz)
12.8 to 119.2dB SPL (±1dB SPL 35kHz)
19.8 to 116.1dB SPL (±3dB SPL 52kHz)
41.4 to 129.0dB SPL (±1dB SPL 80kHz)
54.4 to 135.5dB SPL (±1dB SPL 100kHz)
Auto max/min dB gainAuto or manual, user selectable
Frequency band selectionUser selectable through user-made presets or manual entry
Classification and quantificationLeakQ™, MecQ™, and PDQ Mode™
Leak size and cost estimation /
Mechanical inspection /
Partial discharge type classification
Software
Ease of useIntuitive user interface
Trend graphsFrequency and dB scale
Spot markersdB level reading at center point of the image
Asset IDQR code based asset ID identification
Asset Inspection Status:'As left', 'As found' ; 'Undetermined'
Photo notesUp to 4 photos notes for reference
SourceShow single or multiple sources
ProfilePreset capture profiles
Annotation:Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure.
OtherOperating conditions; Weather notes
Leak valuesLeak costs; Leak volume; LeakQ™ scale
ActionsAction requirements; Action priority level; Action notes
Battery
Batteries (field-replaceable, rechargeable)2 x Rechargeable Li-ion
Battery life6 hours/battery (product includes spare battery)
Battery charging time3 hours
Battery charging systemExternal charger
General Specifications
Standard palettes3: Grayscale, Ironbow, Blue-Red
Operating temperature-10 °C to 40 °C (14 °F to 104 °F)
Storage temperature-20 °C to 70 °C (-4 °F to 158 °F) Without batteries
Relative humidity10 % to 95 % non-condensing
Size (H x W x L)186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches)
Weight (battery included)2.15 kg (4.7 pounds)
Ingress Protection (IP)IP40
Warranty2 year
Fluke Premium CarePremium Care Standard**
Self-diagnostic notificationArray-health test to identify when microphone array needs attention
Supported languagesDutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese
RoHS compliantYes
** Subject to regional availability 
Safety
General safetyIEC 61010-1
Electromagnetic Compatibility (EMC) InternationalIEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2
CISPR 11: Group 1, Class A
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication)
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

Download Datasheet

Models: Fluke ii910 Precision Acoustic Imager

FLK-ii910

ii910 Precision Acoustic Imager

Buy it

Includes:

  • Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 78.74ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.93ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.