English

Fluke Multipoint Power Recorder

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 21.09ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;

Key features

 

  • 2 MS/s sampling system for capturing and viewing high-speed events as fast as 500 ns
  • 4 voltage channels – three phases plus neutral-to-ground. Measure up to 600 Vrms, 1000 Vpeak
  • 5 current channels allow you to monitor neutral and ground current in addition to phases designed to connect to industry-standard 5-amp CT’s. Also available with connections for clamp-on CT’s
  • Measurement system docks with a permanently-mounted base, allowing calibration or service without having to shut down power
  • Capture up to 6,000 simultaneous voltage events with simultaneous current, in each monitoring session
  • Multi-session option allows for 16 sessions, effectively multiplying event capture capability to 96,000 events
  • 128 samples per cycle -- on every cycle at 50 or 60 Hz

Product overview: Fluke Multipoint Power Recorder

High-Speed Capability for Permanent Installation

Designed for permanent installations, Multipoint performs just like the portable Power Recorder simultaneously measuring all power quality parameters, as well as power consumption and harmonics. The system consists of a detachable acquisition unit and a base that manages connections to your power system.

Full Disclosure Technology is included with Multipoint, making it a unique, professional tool that increases your ability to maintain and troubleshoot your plant’s power quality.

Read more about Full Disclosure technology in the Multipoint Power Recorder® datasheet.

Specifications: Fluke Multipoint Power Recorder

  • Technical Data
  • General Specifications
Technical Data: number of channels: 9 (4 voltage, 5 current)
Voltage (phases)
 Range: 100mV – 600 Vms, 1000 V peak
 Resolution: 14 bits, 90 millivolts
 Accuracy +/- (% of reading + floor): +/- (1.5% +0.5V)
Voltage (neutral)
 Range: 10 mV-70 Vms, 100 V peak
 Resolution: 14 bits, 90 millivolts
 Accuracy +/- (% of reading + floor): (1.5% +0.5V)
External current (1942 & 1949)
 Range: Depends upon CT
 Resolution: 14 bits
 Accuracy +/- (% of reading + floor): +/- (0.5% + 0.1% of probe range + probe accuracy)
Internal current (1941 & 1948)
 Range: 20 A maximum
 Resolution: 14 bits
 Accuracy +/- (% of reading + floor): +/-(1% + 0.04 A)
Nominal fundamental frequency
 Range: 50/60 Hz +/- 0.1 Hz
Voltage and current sampling
 128 samples per cycle on 50/60 Hz
Voltage and current sampling rate
 6.4 / 7.7 kS/s depending upon line frequency
Voltage and current rms measurements
 Processed for every full cycle
Power measurements
 W, VA, VAR, PF, dPF, THD, harmonics processed for every full cycle
Waveform fault measurements (1941 & 1942) Sampling rate Impulse voltage
 Range: 6.4 / 7.7 kS/s depending upon line frequency
 Range: 100 – 1000 V peak
 Resolution: 10 bits, 12 volts
 Accuracy +/- (% of reading + floor): +/- (5% + 36 V) over entire range
Impulse measurements (1948 & 1949) Sampling rate Impulse voltage
 Range: 2 MHz
 Range: 100 – 6400 V peak
 Resolution: 10 bits, 12 volts
 Accuracy +/- (% of reading + floor): +/- (5% +36V) over entire range
General Specifications
Event memory
 6,000 simultaneous voltage and current events (96,000 with option 166Z) Multi-session increases storage to 96,000
Communication
 10-base T Ethernet, RJ 45 Connector, Optional TC/PIP Stack enables communication via Internet
Electrical
 Operating Voltages: 85 - 264 V AC, 47 – 440 Hz
 Power Consumption: 40 Watts
 Batteries: Rechargeable NiCd battery maintains operation after power loss for 5 minutes, allowing the monitor to record outage, reclosure attempts, and to resume monitoring upon restoration of power. Real time clock is backed up using a lithium battery with 10-year life
Mechanical
 Size: 31.47 cm x 29.36 cm x 15.24 (cm12.39” x 11.56” x 6”)
 Weight: 6 Kg (9 lbs.)
 Operating Temperature: 0° – 50° C (32° - 122° F), 90% RH non-condensing
Standards
 UL3111
 IEC 868
Warranty
 1 year

Models: Fluke Multipoint Power Recorder

Multipoint Power Recorder 1941

High-Speed Capability for Permanent Installation

Designed for permanent installations, Multipoint performs just like the portable Power Recorder simultaneously measuring all power quality parameters, as well as power consumption and harmonics. The system consists of a detachable acquisition unit and a base that manages connections to your power system.

Full Disclosure Technology is included with Multipoint, making it a unique, professional tool that increases your ability to maintain and troubleshoot your plant’s power quality.

Buy it
  • Standard sampling system
  • 5-A fixed current transformer type
  • PQ Measurements included
  • Power Consumption included
  • Harmonics included
  • Multi-Session Software option
  • TCP/IP Stack option
Multipoint Power Recorder 1942

High-Speed Capability for Permanent Installation

Designed for permanent installations, Multipoint performs just like the portable Power Recorder simultaneously measuring all power quality parameters, as well as power consumption and harmonics. The system consists of a detachable acquisition unit and a base that manages connections to your power system.

Full Disclosure Technology is included with Multipoint, making it a unique, professional tool that increases your ability to maintain and troubleshoot your plant’s power quality.

Buy it
  • High-Speed sampling system
  • External clamp-on current transformer type
  • PQ Measurements included
  • Power Consumption included
  • Harmonics included
  • Multi-Session Software option
  • TCP/IP stack option
Multipoint Power Recorder 1948

High-Speed Capability for Permanent Installation

Designed for permanent installations, Multipoint performs just like the portable Power Recorder simultaneously measuring all power quality parameters, as well as power consumption and harmonics. The system consists of a detachable acquisition unit and a base that manages connections to your power system.

Full Disclosure Technology is included with Multipoint, making it a unique, professional tool that increases your ability to maintain and troubleshoot your plant’s power quality.

Buy it
  • Standard sampling system
  • External clamp-on transformer type
  • PQ Measurements included
  • Power Consumption included
  • Harmonics included
  • Impulse Waveform option
  • Multi-Session Software option
  • TCP/IP Stack option
Multipoint Power Recorder 1949

High-Speed Capability for Permanent Installation

Designed for permanent installations, Multipoint performs just like the portable Power Recorder simultaneously measuring all power quality parameters, as well as power consumption and harmonics. The system consists of a detachable acquisition unit and a base that manages connections to your power system.

Full Disclosure Technology is included with Multipoint, making it a unique, professional tool that increases your ability to maintain and troubleshoot your plant’s power quality.

Buy it
  • High-speed sampling system
  • External clamp-on current transformer type
  • PQ Measurements included
  • Power Consumption included
  • Harmonics included
  • Impulse Waveform included
  • Multi-Session Software option
  • TCP/IP Stack option