Fluke CNX™ a3000 AC Current Clamp Kit
Características principais
The CNX a3000 AC Current Clamp Kit provides measurement of all common electrical parameters.
The CNX 3000 Wireless Multimeter offers:
- True RMS AC and DC voltage measurements to 1000V
- True RMS AC and DC current with 0.01 mA resolution
- Continuity, resistance, diode test, capacitance and frequency measurements
- MIN/MAX Recording
- CAT III 1000 V; CAT IV 600 V; IP54
The CNX a3000 AC Wireless Current Clamp Module provides:
- True RMS AC current measurements to 400 A
- 2% accuracy to 100 Hz, 2-1/2% accuracy to 500 Hz
- Memory recording up to 65,000 readings
- Backlit LCD display
- CAT III 600 V; IP42
Using the optional PC adapter, the CNX wireless troubleshooting system can track up to 10 measurement modules simultaneously, with results sent to a PC for further analysis.
Descrição do produto: Fluke CNX™ a3000 AC Current Clamp Kit
The Fluke CNX a3000 AC Current Clamp Kit is part of the Fluke team of wireless test tools.
Connect the CNX a3000 AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the CNX Wireless Multimeter. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems. Or use as a stand-alone measurement tool or combine with other CNX modules as a system for multiple measurements. From short distances, you can even view readings from modules through closed electrical panels. Plus no more writing down data as the CNX a3000 current module captures up to 65,000 sets of time stamped min/max/avg readings, using the optional PC adapter. CNX wireless test tools also offer increased safety by letting you view readings in a separate location from the test point. Now you can take readings on moving machinery, with only the measurement module in harm’s way.
Especificações: Fluke CNX™ a3000 AC Current Clamp Kit
CNX 3000 Wireless Multimeter
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Detailed Specifications | ||||
AC Voltage | ||||
Range ¹ | Resolution | Accuracy ² ³ | ||
45 Hz to 500 Hz | 500 Hz to 1 kHz | |||
600.0 mV | 0.1 mV | 1.0 % + 3 | 2.0 % + 3 | |
6.000 V | 0.001 V | |||
60.00 V | 0.01 V | |||
600.0 V | 0.1 V | |||
1000 V | 1 V | |||
Notes: ¹ All AC voltage ranges are specified from 1 % of range to 100 % of range. ² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. ³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3. | ||||
DC Voltage, Continuity, Resistance, Diode Test and Capacitance | ||||
Function | Range | Resolution | Accuracy | |
mV | 600.0 mV | 0.1 mV | 0.09 % + 2 | |
V | 6.000 V | 0.001 V | 0.09 % + 2 | |
60.00 V | 0.01 V | |||
600.0 V | 0.1 V | |||
1000 V | 1 V | 0.15 % + 2 | ||
Ω | 600 Ω | 1 Ω | Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer. | |
Ω | 600.0 Ω | 0.1 Ω | 0.5 % + 2 | |
6.000 kΩ | 0.001 kΩ | 0.5 % + 1 | ||
60.00 kΩ | 0.01 kΩ | |||
60.00 kΩ | 0.1 kΩ | |||
600.0 kΩ | 0.001 MΩ | |||
50.00 MΩ | 0.01 MΩ | 1.5 % + 3 | ||
Diode test | 2.000 V | 0.001 V | 1 % + 2 | |
μF | 1000 nF | 1 nF | 1.2 % + 2 | |
10.00 μF | 0.01 μF | |||
100.0 μF | 0.1 μF | |||
9999 μF¹ | 1 μF | 10 % typical | ||
Notes: ¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2. | ||||
AC and DC Current | ||||
Function | Range ¹ | Resolution | Accuracy | |
mA AC (45 Hz to 1 kHz) | 60.00 mA | 0.01 mA | 1.5 % + 3 | |
400.0 mA ³ | 0.1 mA | |||
mA DC ² | 60.00 mA | 0.01 mA | 0.5 % + 3 | |
400.0 mA | 0.1 mA | |||
Notes: ¹ All AC current ranges are specified from 5 % of range to 100 % of range. ² Input burden voltage (typical): 400 mA input 2 mV/mA. ³ 400.0 mA accuracy specified up to 600 mA overload. | ||||
Frequency | ||||
Range | Resolution | Accuracy ¹ | ||
99.99 Hz | 0.01 Hz | 0.1 % + 1 | ||
999.9 Hz | 0.1 Hz | |||
9.999 kHz | 0.001 kHz | |||
99.99 kHz | 0.01 kHz | |||
Notes: ¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. | ||||
Input Characteristics | ||||
Function | Overload Protection | Input Impedance (nominal) | Common Mode Rejection Ratio (1 kΩ unbalance) | Normal Mode Rejection |
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
1100 V RMS | > 10 MΩ < 100 pF | > 60 dB, DC to 60 Hz | ||
1100 V RMS | > 10 MΩ < 100 pF | > 120 dB at DC, 50 Hz or 60 Hz | > 60 dB at 50 Hz or 60 Hz | |
Open circuit test voltage | Full scale | Typical short circuit current | ||
1100 V RMS | < 2.7 V DC | To 6 MΩ: < 0.7 V DC 50 MΩ: < 0.9 V DC | < 350 mA | |
1100 V RMS | < 2.7 V DC | To 6 MΩ: 2.000 V DC | < 1.1 mA | |
Function | Overload Protection | Overload | ||
mA | Fused, 44/100 A, 1000 V FAST Fuse | 600 mA overload for 2 minutes maximum, 10 minutes rest minimum | ||
MIN/MAX Recording | ||||
Function | Accuracy | |||
DC functions | The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration. | |||
AC functions | The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration. | |||
General Specifications | ||||
Maximum voltage between any terminal and earth ground | 1000 V DC or AC RMS | |||
Ω fuse protection from A inputs | 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only | |||
Display (LCD) | Update rate: 4/sec Volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts | |||
Battery type | Three AA Alkaline batteries, NEDA 15A IEC LR6 | |||
Battery life | 300 hours minimum | |||
Temperature | Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C | |||
Relative humidity | 0 % to 90 % (0 °C to 35 °C) 0 % to 75 % (35 °C to 40 °C) 0 % to 45 % (40 °C to 50 °C) | |||
Altitude | Operating: 2,000 m Storage: 12,000 m | |||
Temperature coefficient | 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) | |||
Wireless frequency | 2.4 GHz ISM Band 20 meter range | |||
Size (HxWxL) | 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) | |||
Weight | 340 g (12 oz) | |||
Safety standards | US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition CE European: IEC/EN 61010-1:2010 | |||
Electromagnetic compatibility EMI, RFI, EMC, RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : T68-FWCS IC:6627A-FWCS | |||
Ingress Protection (IP) rating | IP54 | |||
Notes: • Accuracy is specified as ± ([% of reading] + [number of least significant digits]). • All ranges are autoranging. • Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C. |
Fluke CNX a3000 AC Wireless Current Clamp Module
Specifications | |
Range | 400.0 A |
Resolution | 0.1 A |
Accuracy | 400.0 A: 2 % ± 5 digits (10 Hz to 100 Hz), 2.5 % ± 5 digits (100 Hz to 500 Hz) |
Inrush | Max displayed reading: 999.9A |
Crest factor (50 Hz/60 Hz) | 3 at 500 A, 2.5 at 600 A, 1.42 at 1000 A, add 2 % |
Display | 3-1/2 digits, LCD w/backlight |
Log rate/interval | 1 sec minimum/adjustable by PC |
Battery type | 2 AA, NEDA 15 A, IEC LR6 |
Battery life | 400 hours |
Memory | Record up to 65,000 readings |
RF communications | 2.4 GHZ ISM Band |
RF communication range | 20 Meters |
Operating temperature | -10 °C to +50 °C |
Storage temperature | -40 °C to +60 °C |
Operating humidity | 90 % at 35 °C 75 % at 40 °C 45 % at 50 °C |
EMC | EN 61326-1:2006 |
Safety compliance | EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III EN/IEC 61010-2-030:2010 EN/IEC 61010-2-032:2002 |
Pollution degree | 2 |
Temperature coefficient | Add 0.1 X (specified accuracy) / °C (<18 °C or >28 °C) |
Safety rating | CAT IV 600 V |
Certifications | CSA, FCC T68-FWCS IC:6627A-FWCS |
Ingress Protection (IP) rating | IP42 |
Size (HxWxD) | 20.3 cm x 7.49 cm x 3.56 cm (8 in x 2.95 in x 1.4 in) |
Weight | .22 kg (8 oz) |
Jaw opening | 34 mm (1.33 in) |
Manuais + recursos: Fluke CNX™ a3000 AC Current Clamp Kit
- CNX 3000 | Manual do Utilizador
- CNX 3000 | Suplemento do Manual do Utilizador
- CNX 3000 | Manual de Calibração
- CNX 3000 | Guia de consulta rápida
- CNX 3000 | Declaração da volatilidade da memória
- CNX 3000 | Folha de Instruções
- CNX 3000 | Folha de informações de segurança
- CNX 3000 | Suplemento da Folha de informações de segurança
- CNX a3000 | Guia de consulta rápida
- CNX a3000 | Manual de Calibração
- CNX a3000 | Folha de informações de segurança
- CNX i3000 | Folha de informações de segurança
- CNX i3000 | Manual de Calibração
- CNX i3000 | Suplemento do Manual de Calibração
- CNX i3000 | Guia de consulta rápida
- CNX t3000 | Manual de Calibração
- CNX t3000 | Guia de consulta rápida
- CNX t3000 | Folha de informações de segurança
- CNX v3000 | Guia de consulta rápida
- CNX v3000 | Manual de Calibração
- CNX v3000 | Folha de informações de segurança
- CNX v3000, CNX t3000, CNX i3000, CNX a3000 | Declaração da volatilidade da memória
- Radio Frequency Data Class A | Folha de Instruções
- Radio Frequency Data Class B | Folha de Instruções
- v3000 FC, v3001 FC, a3000 FC, a3001 FC, a3002 FC, t3000 FC | Declaração da volatilidade da memória