Fluke 62 MAX+/T+PRO/1AC IR Thermometer, T+PRO Voltage Continuity Tester and Voltage Detector Kit
Características principais
Fluke 62 MAX+ Infrared Thermometer
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to read, even in dark areas.
Fluke T+PRO Voltage and Continuity Tester
- 3 forms of AC/DC voltage detection: light, sound, and vibration.
- Extra heavy-duty, replaceable test leads.
- CAT IV 600, CAT III 1000 V safety rated.
- Continuity beeper.
Fluke 1AC-II VoltAlert™ Non-Contact Voltage Detector
- Voltbeat™ technology and continuous self-test, so always know it’s working.
- Upon detection of voltage, tip glows and beeper sounds.
- Voltage detection of 90 to 1000 VAC.
- CAT IV 1000 V for added protection.
Fluke C115 Soft Case
- Lightweight soft case to provide optimal protection and accessory storage.
Descrição do produto: Fluke 62 MAX+/T+PRO/1AC IR Thermometer, T+PRO Voltage Continuity Tester and Voltage Detector Kit
The rugged Fluke 62 MAX+ IR thermometer teamed with the full featured T+PRO voltage continuity tester and the easy-to-use 1-AC-II non-contact voltage detector, has everything you need to solve problems quickly. Use the IR thermometer to test for overheating in electrical devices, next use the electrical test tools to learn more about the problem safely and conveniently.
Especificações: Fluke 62 MAX+/T+PRO/1AC IR Thermometer, T+PRO Voltage Continuity Tester and Voltage Detector Kit
Fluke 62 MAX+ Infrared Thermometer
Specifications | ||
Temperature range | -30°C to 650°C (-22°F to 1202°F) | |
Accuracy | ±1.0°C or ±1.0% of reading, whichever is greater -10°C to 0°C: ±2.0 -30°C to -10°C: ±3.0 | |
Response time (95%) | < 300 ms (95% of reading) | |
Spectral response | 8 to 14 microns | |
Emissivity | 0.10 to 1.00 | |
Optical resolution | 12:1 (calculated at 90% energy) | |
Display resolution | 0.1°C (0.2°F) | |
Repeatability of readings | ±0.5% of reading or < ±0.5°C (1°F), whichever is greater | |
Power | AA battery | |
Battery life | 8 hours with laser and backlight on | |
Physical Specifications | ||
Weight | 255 g (8.99 oz) | |
Size | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) | |
Operating temperature | 0°C to 50°C (32°F to 122°F) | |
Storage temperature | -20°C to 60°C (-4°F to 140°F), (without battery) | |
Operating humidity | 10% to 90% RH non-condensing at 30°C (86°F) | |
Operating altitude | 2000 meters above mean sea level | |
Storage altitude | 12,000 meters above mean sea level | |
IP rating | IP 54 per IEC 60529 | |
Drop test | 3 meters | |
Vibration and shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms | |
EMC | EN 61326-1:2006 EN 61326-2:2006 | |
Standards and agency approval | Compliance | EN/IEC 61010-1: 2001 |
Laser safety | FDA and EN 60825-1 Class II |
Fluke T+PRO Electrical Testers
Specifications | ||
Temperature | Operating | -10°C to 55°C (14°F to 131°F) |
Storage | -30°C to 60°C (-22°F to 140°F) | |
Relative humidity | 0°C to 30°C (32°F to 86°F): 90% | |
30°C to 40°C (86°F to 104°F): 75% | ||
40°C to 50°C (104°F to 122°F): 45% | ||
Altitude | Operating | 2,000 m (approx. 6,561.6 ft) |
Storage | 10,000 m (approx. 32,808.4 ft) | |
Battery type/life | AAA (2); 40 hours | |
Shock, vibration | Sinusoidal vibration per MIL-PRF-28800F for a Class 2 instrument | |
Safety | ISA-82.02.01 (IEC 61010-1 Mod) Second Edition, CAN/CSA-C22.2 No. 61010-1 Second Edition, IEC 61010 - 1 to 1000 V CAT III/600 V CAT IV | |
Compliance to NFPA 70E1 | ||
AC bandwidth | 45 Hz to 66 Hz | |
Maximum working voltage | 1000 V AC/DC | |
Maximum measurable voltage | 600 V AC/DC | |
Duty cycle | Indefinitely for voltages up to 240 V | |
For voltages between 240 V and 600 V the duty cycle is 30 s on / 300 s off | ||
For voltages above 240 V the tester must connect to a voltage source only for a MAXIMUM of 30 s and then disconnect for a MINIMUM of 300 s | ||
Voltage hazard LED | LEDs turn on at voltages > 30 V AC/DC ±35% | |
LED voltage indication levels | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V | |
LED voltage indication levels for Canadian version | 12 V, 24 V, 48 V, 120 V, 208 V, 240 V, 347 V, 480 V, 600 V | |
LEDs | LEDs turn on between 90% and 100% of the indicated voltage on the LED, except for the 12 V LED which turns on between 50% and 100% | |
LCD accuracy on T+PRO only | AC voltage | ±(3% rdg + 2 digits) |
DC voltage | ±(2% rdg + 2 digits) | |
Resistance | ±(5% rdg + 3 digits) | |
LCD resolution | 0.1 V for voltages < 50 V, 1 V for voltages ≥ 50 V 0.01 kΩ for resistance measurement (For T+PRO Only) | |
GFCI test current | 100 V - 150 V @ 6 mA - 9 mA AC, 150 V - 240 V < 12 mA | |
Standard input test current | < 5 mA | |
Size (H x W x L) | 1.3 x 2.15 x 7.6 in (3.3 x 5.46 x 19.3 cm) | |
Weight | 9.9 oz (0.28 kg) | |
1. When used properly per Article 110.9 Use of Equipment (A) Test Instruments and Equipment. |
Fluke 1AC-II VoltAlert
Specifications | ||
Operating principle | Senses the steady state electrostatic field produced by ac voltage through insulation without requiring contact to the bare conductor. A red glow at the tip and a beeping noise (if not switched OFF) indicates the presence of voltage. | |
Voltage sensing ranges | Nominally, 90 VAC to 1000 VAC or 200 VAC to 1000 VAC depending on model, 45 Hz to 405 Hz; also a 20 V to 90 V control circuit model | |
Detector tip style | Blade or round, depending on model | |
Light source | One high intensity red LED | |
Agency approvals | c CSA us, CE, C-Tick | |
Safety rating | 1000 V, CAT IV | |
IP rating | IP 40 | |
Operating temperature | -10°C to 50°C | |
Operating humidity ranges | 0% to 95% | (0°C to 30°C) |
0% to 75% | (30°C to 40°C) | |
0% to 45% | (40°C to 55°C) | |
Operating altitude | 3000 meters | |
Batteries | 2 AAA alkaline batteries included | |
Product does not respond to random electrostatic discharge. |
Modelos: Fluke 62 MAX+/T+PRO/1AC IR Thermometer, T+PRO Voltage Continuity Tester and Voltage Detector Kit
Fluke 62 MAX+/T+PRO/1AC
Inclui:
- Termómetro de IR Fluke 62 MAX+
- Verificador eléctrico Fluke T+Pro
- Detector de tensão Fluke 1AC II VoltAlert
- Mala flexível C115