Ti95 Fluke Connect FCA Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 51.72ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Ti95 Fluke Connect FCA Kit | Fluke
  • Ti95 Fluke Connect FCA Kit | Fluke
  • Ti95 Fluke Connect FCA Kit | Fluke
  • Ti95 Fluke Connect FCA Kit | Fluke

Key features

The Fluke Ti95 Infrared Camera offers:

  • The only wireless industrial infrared camera in its price class¹ – take advantage of the benefits of Fluke Connect® by seamlessly gathering and sharing inspection results instantly
  • Superior image quality, up to 23% better spatial resolution than other competitive models in this price class¹
  • 80x80 resolution
  • Removable 8 GB SD Memory Card
  • 8 GB Fluke Connect® wireless SD Card
  • Find potential problems faster and easier with IR-Fusion® picture-in-picture mode
  • 2 megapixel built-in digital camera
  • Large 3.5 inch LCD - 32% larger screen than other competitive models lets you clearly see what you are measuring
  • Smart Battery System - Lithium ion smart battery pack with five-segment LED display to show charge level
  • Rugged, lightweight, point–and–shoot infrared camera

The Fluke 3000 FC Series Wireless Multimeter offers:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The Fluke a3001 FC Wireless iFlex™ AC Current Module offers:

  • One (1) true-RMS flexible current meter
  • One (1) iFlex i2500-10 flexible current probe
  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Magnetic hanging strap

¹ Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.

Get a free demo

Product overview: Ti95 Fluke Connect FCA Kit

Fluke Connect®

See How It Works
Fluke Connect FAQs

Troubleshooting just got easier with the Ti95 Fluke Connect FCA Kit with Ti95 Infrared Camera, 3000 FC DMM, and a3001 FC iFlex® Module. This kit features the only wireless industrial infrared camera in its price class¹, the Ti95. Safely capture AC current measurements with your a3001 FC iFlex Module from up to 20 meters away on the 3000 FC DMM, while simultaneously conducting an infrared inspection with your Ti95 infrared camera. Upload your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.

¹ Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.

Specifications: Ti95 Fluke Connect FCA Kit

Fluke Ti95 Infrared Camera

Key Features
IFOV (spatial resolution) 5.6 mRad
Resolution 80 x 80 (6,400 pixels)
Field of view 26° H x 26° V
Wireless connectivity Yes
Fluke Connect™ app compatible Yes, with included wireless SD card (where available)
IR-Fusion® technology PIP (46 cm (18 in) and beyond)
Focus system Fixed focus 46 cm (18 in) and beyond
Ruggedized display 3.5 inch diagonal (portrait format)
Rugged, ergonomic design for one-handed use Yes
Thermal sensitivity (NETD) ≤ 0.10°C at 30°C target temp (100 mK)
Temperature measurement range (not calibrated below -10°C) -20°C to +250°C (-4°F to +482°F)
Level and span Smooth auto and manual scaling
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.5°C
Minimum span (in auto mode) 5°C
Built-in digital camera (visible light) 2 megapixel industrial performance
Frame rate 9 Hz only
Data Storage and Image Capture
Extensive SD memory system Removable 8 GB SD memory card and 8 GB wireless SD card (where available)
Direct download via USB-to-PC connection
Image capture, review, save mechanism One-handed image capture, review, and save capability
File formats image Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp, .jpg) files
Memory review Thumbnail view navigation and review selection
Software SmartView® software, Fluke Connect™, and SmartView® Mobile app - full analysis and reporting software
Export file formats with SmartView® software BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Battery
Batteries (field-replaceable, rechargeable) One lithium ion smart battery pack with five-segment LED display to show charge level
Battery life Four+ hours continuous use per battery pack (assumes 50% brightness of LCD and average usage)
Battery charge time 2.5 hours to full charge
AC battery charging system In-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay AC battery charger (110 VAC to 220 VAC, 50/60 Hz) or optional 12 V automotive charging adapter.
AC operation AC operation with included power supply (110 VAC to 220 VAC, 50/60 Hz). AC mains adapters included.
Power saving User selectable sleep and power off modes
Temperature Measurement
Accuracy ±2°C or 2% (at 25°C nominal, whichever is greater)
On-screen emissivity correction Yes (both number and table)
On-screen reflected background temperature compensation Yes
Color Palettes
Standard palettes 6: Ironbow, blue-red, high-contrast, amber, hot metal, grayscale
General Specifications
Infrared spectral band 9 μm to 15 μm (long wave)
Operating temperature -10°C to +50°C (14°F to 122°F)
Storage temperature -20°C to +50°C (-4°F to 122°F)
Relative humidity 10% to 95%, non-condensing
Center-point temperature measurement Yes
Spot markers Hot and cold spot markers
Center box (MIN-MAX-AVG) Fixed-size measurement box with MIN-MAX-AVG temp
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
Electromagnetic compatibility EN 61326-1:2006 IEC 61326-1:2005
C Tick IEC/EN 61326-1
US FCC EN61326-1; FCC Part 5
Vibration 2G, IEC 68-2-6
Shock 25G, IEC 68-2-29
Drop Engineered to withstand 2 meter (6.5 feet) drop
Size (H x W x L) 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
Weight (battery included) 0.726 kg (1.6 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available
Recommended calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
 

Fluke 3000 FC Wireless Multimeter

* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18°C to 28°C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ±([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹ / Resolution 600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 2 3 4 45 Hz to 500 Hz 1.0 % + 3
500 Hz to 1 kHz 2.0% + 3
1. All AC voltage ranges are specified from 1 % of range to 100 % of range.
2. Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add ±(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mV Range / Resolution 600.0 mV / 0.1 mV
Accuracy 0.09% + 2
V Range / Resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V
Accuracy 0.09% + 2
0.15% + 2
))) Range / Resolution 600 Ω / 1 Ω
Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Range / Resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ
Accuracy 0.5% + 2
0.5% + 1
1.5% + 3
Diode test Range / Resolution 2.000 V / 0.001 V
Accuracy 1% + 2
µF Range / Resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF1 / 1 μF
Accuracy 1.2% + 2
10% typical
1. In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range 1 / Resolution 60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy 1.5% + 3
mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA
Accuracy 0.5% + 3
1. All AC current ranges are specified from 5 % of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution 99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz
Accuracy 1 0.1% + 1
1. Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function Overload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale voltage Typical short circuit current
To 6 MΩ 50 MΩ Typical short circuit current
1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA
1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA
mA Function
Overload protection Fused, 44/100 A, 1000 V FAST Fuse
Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functions The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 VDC or AC rms
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate 4/sec
Volts, amps, ohms 6000 counts
Frequency 10,000 counts
Capacitance 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m
Temperature Operating -10°C to 50°C
Storage -40°C to 60°C
Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Relative humidity 0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C)
Altitude Operating 2,000 m
Storage 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Certifications CSA, FCC, CE
Ingress Protection (IP) rating IP54
Pollution Degree 2
Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in)
Weight 340 g (12 oz)
Warranty Three years
Not compatible with Fluke CNX test tools
 

Fluke a3001 FC Wireless iFlex® AC Current Module

Specifications
Range 0.5 A to 2500 A AC
Resolution 0.1 A
Accuracy 3% ±5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz / 60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
add 2% for C.F. > 2
LCD w/backlight 3½ digits
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed Up to 20 m
Obstructed, sheetrock wall Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m
Operating temperature -10°C to +50°C
Storage temperature -40°C to +60°C
Temperature coefficient Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C)
Operating humidity 90% at 35°C
75% at 40°C
45% at 50°C
Altitude Operating 2,000 m
Storage 12,000 m
EMC EN 61326-1:2006
Safety compliance IEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution Degree 2
Jaw opening 25.4 cm (10 in) coil
Size (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in)
Weight .22 kg (8 oz)
Warranty Three years
Not compatible with Fluke CNX test tools

Models: Ti95 Fluke Connect FCA Kit

FLK-Ti95 9HZ/FCA
FLK-Ti95 9HZ/FCA

Includes:

  Fluke Ti95 Thermal Imager:
  • AC power adapter
  • Lithium ion smart battery (1)
  • USB cable
  • SD memory card
  • Fluke Connect™ wireless SD Card (where available, shipped separately in non-European countries)
  • Soft transport bag
  • Adjustable hand strap (left- or right-handed use)
  • Printed users' manual in English, Spanish, French, German and Simplified Chinese, all other manuals on CD
  • SmartView® software
  • Warranty registration card

Fluke 3000 FC Wireless Digital Multimeter with three AA batteries - installed:
  • TL175 Test Leads (1 pair)
  • AC175 Alligator Clips (1 pair)
  • C3003 3-compartment soft case
  • Information pack

Fluke a3001 FC Wireless iFlex AC Current Module with two AA batteries - installed:
  • iFlex 10"" coil (1)
  • Magnet/strap (1)

Reviews: Ti95 Fluke Connect FCA Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 129.3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;