Key features
- Superior image quality, up to 84% better spatial resolution than other competitive models in this price class¹
- 80 x 80 resolution
- Removable 4GB SD memory card
- Find potential problems faster and easier with IR-Fusion® picture-in-picture mode
- 2 megapixel built-in digital camera
- 3.5 inch LCD
- Smart Battery System - Lithium ion smart battery pack with five-segment LED display to show charge level
- Rugged, lightweight, point–and–shoot infrared camera
¹ Class is defined as an industrial handheld infrared camera in the same price range based on MSRP as of May 1, 2014.
Product overview: Fluke Ti95 Infrared Camera
BETTER detail, BIGGEST display, BEST VALUE in their class¹
Images were captured under the same conditions and from the same distance of 1.2 m (4 ft) by a professional thermographer and exported in a JPEG format. Except for the captions in the lower, left-hand corner of each image, images are displayed as saved by each infrared camera.
- See more detail with 23% better spatial resolution¹ – increases the detail in your inspection target
- Easier to see potential problems with a 32% larger display¹
Prevent unexpected loss of power with pop in/pop out replaceable smart batteries with handy LED charge level indicator.
Easy image transfer and more flexibility with replaceable 12 GB of memory capacity.
SmartView® software® is included with all Fluke infrared camera.
¹Compared to industrial handheld infrared cameras with list prices up to $2,000.00 (USD) as of September 17, 2014.
²Within provider's wireless service area.
Specifications: Fluke Ti95 Infrared Camera
Key Features | |
IFOV (spatial resolution) | 5.6 mRad |
Detector resolution | 80x80 (6,400 pixels) |
Field of view | 26 °H x 26 °V |
Minimum focus distance | 46 cm (18 in) |
Focus system | Focus free (fixed focus) |
Wireless connectivity | Fluke Connect™ app compatible with included wireless SD Card1 |
IR-Fusion® technology | IR-Fusion® Picture-in-Picture (AutoBlend™mode available inSmartView® software) |
Display | 3.5 inch diagonal (portrait format) |
Design | Rugged, lightweight, ergonomic design for one-handed use |
Thermal sensitivity (NETD) | ≤ 0.10 °C at 30 °C target temp (100 mK) |
Temperature measurement range | -20 °C to +250 °C (-4 °F to +482 °F) |
Built-in digital camera (visible light) | 2 megapixel industrial performance |
Frame rate | 9 Hz |
Data Storage and Image Capture | |
Extensive memory options | Removable 4 Gb SD memory card and 8 Gb wireless SD card (where available); direct download via USB-to-PC connection |
File formats image | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp, .jpg) files |
SmartView® software | SmartView® software, Fluke Connect™1, and SmartView® Mobile App—full analysis and reporting software |
Battery | |
Batteries (field-replaceable, rechargeable) | One lithium ion smart battery pack with five-segment LED display to show charge level |
AC battery charging system | In-imager charging. Optional two-bay battery charger or optional 12 V automotive charging adapter |
Temperature Measurement | |
Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
General Specifications | |
Color palettes | 6 standard: Ironbow, Blue-Red, High-Contrast, Amber, Hot Metal, Grayscale |
Spot temp | Hot and cold spot markers |
Center box | Fixed-size measurement box with MIN-MAX-AVG temp |
Drop | Engineered to withstand 2 meter (6.5 feet) drop |
Size (H x W x L) | 28.4 cm x 8.6 cm x 13.5 cm (11.2 in x 3.4 in x 5.3 in) |
Weight (battery included) | 0.73 kg (1.6 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Notes | |
1Fluke Connect™ not available in all countries |
Models: Fluke Ti95 Infrared Camera
- Infrared camera
- AC power adapter
- Lithium ion smart battery (1)
- USB cable
- SD memory card
- Soft transport bag
- Adjustable hand strap (left- or right-handed use)
- Warranty registration card
Available for free download:
- SmartView® Analysis and Reporting Software »
- Manual »
Manuals + resources: Fluke Ti95 Infrared Camera
- Saving measurements with AutoRecord™ measurements
- Connecting multiple tools at the same time with Fluke Connect®
- How to email a measurement using the Fluke Connect app
- What is Fluke Connect®
- Connecting a thermal imager to your iPhone
- Performing predictive maintenance with Fluke Connect™
- Connecting the T3000 FC with the Fluke Connect™ app
- Measuring from a safe distance using the Fluke Connect™ app
- Fluke Infrared Cameras: LaserSharp® Auto Focus
- Identifying intermittent conditions with TrendIt™ graphs
- Introduction to 789FC
- How to save measurements to EquipmentLog™ history
- Share equipment health with EquipmentLog™ history
- How to share measurements on equipment using the Fluke Connect™ app
- Using ShareLive™ video call to share live measurements and video
- How to record measurements and graphs
- Ti400 LaserSharp<sup>®</sup> Auto Focus
- Viewing and graphing three phase measurements
- Measurement history in one place using EquipmentLog™ history
- How to create an equipment baseline with EquipmentLog™ history