Key features

  • Intrinsically safe multifunction process calibrator
  • Meets I.S. Class I, Division 1 Groups B-D, 171°C compliance standards
  • Measures volts DC, mA, RTDs, thermocouples, frequency, and ohms
  • Sources or simulates volts DC, mA, RTDs, thermocouples, frequency and ohms

Product overview: Fluke 725Ex Series Process Calibrator

Fluke 725Ex provides an intrinsically safe, simple and powerful multifunction calibration solution

The 725Ex is an intrinsically safe multifunction process calibrator for use in explosion endangered areas. It is powerful, yet easy to use. Combine the 725EX with any of the eight Fluke 750PEx Pressure Modules (sold separately), and you’ll be able to calibrate almost any process instrument likely to need service in an area where explosive gasses may be present.

The 725EX sources and measures almost all process parameters including mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules. Its split display lets you view input and output values simultaneously to calibrate transmitters. For valve and I/P tests, you can source mA while measuring pressure. The 725Ex has auto-stepping and auto-ramping for remote testing, plus 25% stepping for fast linearity tests.

From the moment you pick it up, the Fluke 725Ex is ready to perform. Its simple controls, without menus, make operation easy. Its memory functions make set up fast. And its rugged design lets it work as hard as you do.

Other useful features:

  • Pressure switch test function to capture set, reset, and deadband values
  • Small, streamlined shape, and rugged, reliable design that stands up to field use
  • Simple, push-button user interface for easy operation
  • Provides two-channel simultaneous source and measure capability to calibrate transmitters
  • Powers transmitters during test using loop supply
  • Stores frequently-used test setups for later use
  • Measures pressure to 3,000 psi/200 bar using any of the eight intrinsically safe Fluke 700PEx Pressure Modules to calibrate pressure transmitters and I/P devices

What's in the box:

  • Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator
  • (1 set) AC72 alligator clips
  • (1 pair) stackable test leads
  • (1 pair) TL75 test leads
  • NIST- traceable calibration report and data
  • Quick Reference Guide
  • 3-year warranty

Specifications: Fluke 725Ex Series Process Calibrator

Measurement Accuracy
Voltage DC30.000 V0.02% + 2 counts (upper display)
10.000 V0.02% + 2 counts (lower display)
90.00 mV0.02% + 2 counts
-10.00 mV to 75.00 mV0.025% + 1 count (via TC connector)
Current DC24.000 mA0.02% + 2 counts
Resistance0.0 to 400.0 Ω0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire)
401 to 1500 Ω0.5 Ω (4-wire), 1 Ω (2- and 3-wire)
1500 to 3200 Ω1 Ω (4-wire), 1.5 Ω (2- and 3-wire)
Frequency2.0 to 1000.0 CPM0.05% + 1 count
1.0 to 1100.0 Hz0.05% + 1 count
1.00 to 10.00 kHz0.05% + 1 count
Sensitivity1 V peak-to-peak-minimum
PressureAccuracy from 0.025% of range using any of 8 intrinsic safe pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC100.00 mV0.02% + 2 counts
10.000 V0.02% + 2 counts
-10.00 mV to 75.00 mV0.025% + 1 count (via TC connector)
Current DC24.000 mA (source)0.02% + 2 counts
24.000 mA (simulate)0.02% + 2 counts
Resistance15.0 to 400.0 Ω0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA)
401 to 1500 Ω0.5 Ω (excitation current 0.05 to 0.8 mA)
1500 to 3200 Ω1 Ω (excitation current 0.05 to 0.4 mA)
Frequency2.0 to 1000.0 CPM0.05%
1.0 to 1100.0 Hz0.05%
1.00 to 10.00 kHz0.25%
Waveform5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure accuracyNI-1200.2°C
PT-100 (385)0.33°C
PT-100 (393)0.3°C
PT-100 (JIS)0.3°C
PT-200 (385)0.2°C
PT-500 (385)0.3°C
PT-1000 (385)0.2°C
Resolution0.1°C
J0.7°C
K0.8°C
T0.8°C
E0.7°C
R1.8°C
S1.5°C
B1.4°C
L0.7°C
U0.75°C
N0.9°C
ResolutionJ, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK0.6°C
BP1.2°C
Source accuracyNI-1200.2°C
PT-100 (385)0.33°C
PT-100 (393)0.3°C
PT-100 (JIS)0.3°C
PT-200 (385)0.2°C
PT-500 (385)0.3°C
PT-1000 (385)0.2°C
Resolution0.1°C
 Accuracy stated for 4-wire measurement.
J0.7°C
K0.8°C
T0.8°C
E0.7°C
R1.4°C
S1.5°C
B1.4°C
L0.7°C
U0.75°C
N0.9°C
ResolutionJ, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK0.6°C
BP1.2°C
Specifications
Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature
RampsSlow ramp, Fast ramp, 25% step-ramp
Loop power functionVoltage12 V
Accuracy10%
Maximum current22 mA, short circuit protected
Step functionsSource functionsVoltage, current, resistance, frequency, temperature
Steps25% of range, 100% of range
Safety specifications
Agency approvalsI.S. Class I, Division 1 Groups B-D
Mechanical and General Specifications
Size130 x 236 x 61 mm (5.188 x 9.291 x 2.402 in)
Weight0.85 kg (1.874 lbs.)
Batteries4 AA alkaline batteries
WarrantyThree year
Battery replacementSeparate battery compartment, accessible without breaking calibration seal
Side port connectionsPressure module connector

Models: Fluke 725Ex Series Process Calibrator

Fluke 725Ex
Fluke 725Ex Intrinsically Safe Multifunction Process Calibrator

Buy it

Includes:

  • One set of AC72 alligator clips
  • One set of stackable test leads
  • One set of TL75 testleads
  • User manuals
  • NIST- traceable calibration report and data
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 117.36ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.3ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.