English

Ti110 a3001 FC iFlex® Kit

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.16ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;

Key features

The Ti110 offers:

  • Exclusive IR-OptiFlex™ focus system - ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger
  • Always have references handy - IR-PhotoNotes™ annotation system - Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas
  • Find problems faster and easier IR-Fusion® technology
  • Fluke Connect® App – See It. Save It. Share It. All the facts, right in the field
  • Multi-mode video recording - focus-free video in visible light and infrared with IR-Fusion
  • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal)

The 3000 FC Wireless Multimeter offers:

  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54

The iFlex™ Wireless Current Module allows you to measure around awkward sized conductors or get into tight spaces and makes wire access easier. The a3001 FC offers:

  • One (1) true-RMS flexible current meter
  • One (1) iFlex i2500-10 flexible current probe
  • Measure up to 2500 A AC
  • Use as a standalone meter or as part of the system
  • Logging function for recording and saving up to 65,000 readings
  • Inrush function
  • Magnetic hanging strap

Product overview: Ti110 a3001 FC iFlex® Kit

Fluke Connect®

Learn more about Fluke Connect

Industrial and commercial professionals can save time and money by identifying problems before they become costly failures with the Ti110 a3001 FC iFlex® Kit. Connect the a3001 FC iFlex® AC Wireless Current Module to your test point and view the results up to 20 meters away on your 3000 FC DMM. The a3001 FC iFlex® module allows you to measure around tight, awkward spaces and/ or sizes and makes wire access easier. The Ti110 thermal camera comes standard with IR Fusion® Technology - the blending of digital and infrared images into a single image making precise documentation quick and easy. Upload all your measurement data to the Cloud via your smart phone and you can analyze and share your inspection results for each piece of equipment from anywhere, with any team member, at any time - only with Fluke Connect.

Simplify and streamline your reporting with our easy to use SmartView® software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite.

Specifications: Ti110 a3001 FC iFlex® Kit

Fluke 110 Thermal Camera

 
Detailed Specifications
Key Features
IFOV (spatial resolution) 3.39 mRad
Detector resolution 160x120 (19,200 pixels)
Field of view 22.5 °H x 31 °V
Minimum focus distance 15 cm (6 in)
Focus system IR-OptiFlex™ focus system (focus free and manual focus)
Wireless connectivity Fluke Connect® app compatible with included wireless SD Card1
IR-Fusion® technology IR-Fusion® AutoBlend™ mode and Picture-in-Picture
Display 3.5 inch diagonal (portrait format)
Design Rugged, lightweight, ergonomic design for one-handed use
Thermal sensitivity (NETD) ≤ 0.10 °C at 30 °C target temp (100 mK)
Temperature measurement range -20 °C to +250 °C (-4 °F to +482 °F)
Built-in digital camera (visible light) 2 megapixel industrial performance
Frame rate 30 Hz or 9 Hz versions
Data Storage and Image Capture
Extensive memory options Removable 4 Gb SD memory card and 8 Gb wireless SD card (where available); direct download via USB-to-PC connection
File formats image Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
No analysis software required for non-radiometric (.bmp, .jpg and .avi) files
SmartView® software SmartView® software, Fluke Connect®1, and SmartView® Mobile App—full analysis and reporting software
Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera
IR-PhotoNotes™ Yes (3 images)
Video recording Standard
Battery
Batteries (field-replaceable, rechargeable) One lithium ion smart battery pack with five-segment LED display to show charge level
AC battery charging system In-imager charging. Optional two-bay battery charger or optional 12 V automotive charging adapter
Temperature Measurement
Accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes (both value and table)
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
General Specifications
Color palettes 8 standard and 3 Ultra Contrast™: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Color alarms (temperature alarms) High temperature, low temperature
User-definable spot markers 3 user definable spot markers on camera and in SmartView® software
Center box Expandable-contractible measurement box with MIN-MAX-AVG temp
Drop Engineered to withstand 2 meter (6.5 feet) drop
Size (H x W x L) 28.4 cm x 8.6 cm x 13.5 cm (11.2 in x 3.4 in x 5.3 in)
Weight (battery included) 0.73 kg (1.6 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty Two-years (standard), extended warranties are available

Fluke 3000 FC Wireless Digital Multimeter


* For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
 
Detailed Specifications
AC Voltage
Range 1ResolutionAccuracy 2 3 4
45 Hz to 500 Hz500 Hz to 1 kHz
600.0 mV0.1 mV1.0 % + 32.0 % + 3
6.000 V0.001 V
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V
1 All AC voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add ± (2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
FunctionRangeResolutionAccuracy
mV600.0 mV0.1 mV0.09 % + 2
V6.000 V0.001 V0.09 % + 2
60.00 V0.01 V
600.0 V0.1 V
1000 V1 V0.15 % + 2
600 Ω1 ΩMeter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
600.0 Ω0.1 Ω0.5 % + 2
6.000 kΩ0.001 kΩ0.5 % + 1
60.00 kΩ0.01 kΩ
60.00 kΩ0.1 kΩ
600.0 kΩ0.001 MΩ
50.00 MΩ0.01 MΩ1.5 % + 3
Diode test2.000 V0.001 V1 % + 2
µF1000 nF1 nF1.2 % + 2
10.00 μF0.01 μF
100.0 μF0.1 μF
9999 μF11 μF10 % typical
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
FunctionRange 1ResolutionAccuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA0.01 mA1.5 % + 3
400.0 mA 30.1 mA
mA DC 260.00 mA0.01 mA0.5 % + 3
400.0 mA 30.1 mA
1 All AC current ranges are specified from 5 % of range to 100 % of range.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.
Frequency
RangeResolutionAccuracy 1
99.99 Hz0.01 Hz0.1 % + 1
999.9 Hz0.1 Hz
9.999 kHz0.001 kHz
99.99 kHz0.01 kHz
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
FunctionOverload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance)Normal mode rejection
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
1100 V RMS> 10 MΩ < 100 pF> 60 dB, DC to 60 Hz 
1100 V RMS> 10 MΩ < 100 pF> 120 dB at DC, 50 Hz or 60 Hz> 60 dB at 50 Hz or 60 Hz
Open circuit test voltageFull scale voltageTypical short circuit current
To 6 MΩ50 MΩ
1100 V RMS< 2.7 V DC< 0.7 V DC< 0.9 V DC< 350 mA
1100 V RMS< 2.7 V DC2.000 V DC< 1.1 mA
mA Function
Overload ProtectionFused, 44/100 A, 1000 V FAST Fuse
Overload600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording Accuracy
DC functionsThe specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functionsThe specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground1000 V DC or AC RMS
Ω fuse protection from A inputs0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD)Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery typeThree AA Alkaline batteries, NEDA 15A IEC LR6
Battery life250 hours minimum
RF communications 2.4 GHZ ISM Band
RF communication range Open air, unobstructed: Up to 20m
Obstructed, sheetrock wall: Up to 6.5m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5m
TemperatureOperating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature coefficient0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative humidity0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
AltitudeOperating: 2,000 m
Storage: 12,000 m
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
Safety complianceANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
CertificationsCSA, FCC, CE
Ingress Protection (IP) ratingIP54
Pollution degree2
Size (H x W x L)4.75 cm x 9.3 cm x 20.7 cm
(1.87 in x 3.68 in x 8.14 in)
Weight340 g (12 oz)
WarrantyThree years

Note: Not compatible with Fluke CNX test tools

Fluke a3001 FC Wireless iFlex AC Current Module

Specifications
Range 0.5 A to 2500 A AC
Resolution0.1 A
Accuracy3 % ± 5 digits (5 Hz to 500 Hz)
Crest factor (50 Hz/60 Hz)3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
LCD w/backlight 3½ digits
Log rate/interval1 sec minimum/adjustable by PC or front panel
Battery type2 AA, NEDA 15 A, IEC LR6
Battery life400 hours
MemoryRecord up to 65,000 readings
RF communications2.4 GHZ ISM Band
RF communication rangeOpen air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Temperature coefficientAdd 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Operating humidity90 % at 35 °C, 75 % at 40 °C, 45 % at 50 °C
AltitudeOperating: 2,000 m
Storage: 12,000 m
EMCEN 61326-1:2006
Safety complianceIEC 61010-1, 600 V CAT IV/1000 V CAT III, 3rd edition
Safety ratingCAT IV 600 V, CAT III 1000 V
CertificationsCSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating IP42
Pollution degree2
Jaw opening25.4 cm (10 in) coil
Size (HxWxD)16.5 cm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in)
Weight.22 kg (8 oz)
WarrantyThree years

Note: Not compatible with Fluke CNX test tools

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 73.64ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.51ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.