With true-rms ac voltage and current measurements, the Fluke 375 Clamp Meter can read up to 600 V and 600 A in both ac and dc modes, and is capable of frequency measurement up to 500 Hz. Additionally, the 375 is compatible with the new iFlex flexible current probe (sold separately), which expands the measurement range to 2500 A ac.

Safety Conformance
EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV

Features and benefits

  • iFlex flexible current probe expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure awkward sized conductors and improved wire access.
  • CAT IV 600 V, CAT III 1000 V
  • True-rms ac voltage and current for accurate measurements on non-linear signals
  • 500 mV dc measurement range to interface with other accessories
  • Integrated low pass filter and state of the art signal processing allows for use in noisy electrical environments while providing stable readings
  • Proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it
  • Ergonomic design fits in your hand and can be used while wearing protective equipment
  • Large, easy to read backlight display automatically sets the correct measurement range so you do not need to change the switch positions while taking a measurement
  • Three-year warranty
  • Soft carrying case

Safety conformance
EN/IEC 61010-1:2001; 1000V CAT III, 600V CAT IV

What’s the difference between the clamp meter models?

  Fluke-365 Fluke-373 Fluke-374 Fluke-375 Fluke-376 Fluke-381
Measure ac current 200.0 A 600.0 A 600.0 A 600.0 A 999.9 A 999.9 A
Measure ac current via iFlex     2500 A 2500 A 2500 A 2500 A
Measure ac voltage 600.0 V 600.0 V 600.0 V 600.0 V 1000.0 V 1000.0 V
Measure continuity ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω ≤ 30 Ω
Measure dc current 200.0 A   600.0 A 600.0 A 999.9 A 999.9 A
Measure dc voltage 600.0 V   600.0 V 600.0 V 1000.0 V 1000.0 V
Measure resistance 6,000 Ω 6,000 Ω 6,000 Ω 60k Ω 60k Ω 60k Ω
Measure frequency       500 Hz 500 Hz 500 Hz
Measure inrush     100 mS 100 mS 100 mS 100 mS
Work in poorly lit areas Backlight Backlight Backlight Backlight Backlight Backlight
Measure non-linear loads True-rms True-rms True-rms True-rms True-rms True-rms
Electrical Specifications
AC Current via Jaw
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ± 5 digits (10-100 Hz)
2.5% ± 5 digits (100-500 Hz)
Crest Factor (50/60 Hz) 3 @ 500 A
Add 2% for C.F. > 2
AC Current via Flexible Current Probe
Range 2500 A
Resolution 0.1 A (≤ 600 A)
1 A (≤ 2500 A)
Accuracy 3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Distance from Optimum i2500-10 Flex i2500-18 Flex Error
Flexible current probe A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5%
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0%
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0%
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range 600.0 A
Resolution 0.1 A
Accuracy 2% ± 5 digits
AC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1.5% ± 5 digits (20 – 500 Hz)
DC Voltage
Range 600.0 V
Resolution 0.1 V
Accuracy 1% ± 5 digits
mV dc
Range 500.0 mV
Resolution 0.1 mV
Accuracy 1% ± 5 digits
Frequency via Jaw
Range 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 10 Hz, ≥10 A
10 – 100 Hz, ≥5 A
100 – 500 Hz, ≥10 A
Frequency via Flexible Current Probe
Range 5.0 - 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ± 5 digits
Trigger Level 5 – 20 Hz, ≥ 25 A
20 – 100 Hz, ≥ 20 A
100 – 500 Hz, ≥ 25 A
Resistance
Range 60 kΩ
Resolution 0.1 Ω (≤ 600 Ω)
1 Ω (≤ 6000 Ω)
10 Ω (≤ 60 kΩ)
Accuracy 1% ± 5 digits
Capacitance
Range 1000 μF
Resolution 0.1 μF (≤ 100 μF)
1 μ F (≤ 1000 μF)
Accuracy 1% ± 4 digits
Mechanical Specifications
Size (L x W x H) 246 mm x 83 m x 43 mm
Weight 388 g
Jaw Opening 34 mm
Flexible Current Probe Diameter 7.5 mm
Flexible Current Probe Cable Length
(head to electronics connector)
1.8 m
Environmental Specifications
Operating Temperature 10°C – +50°C
Storage Temp -40°C – +60°C
Operating Humidity Non condensing (< 10 –°C)
≤ 90% RH (at 10°C – 30°C)
≤ 75% RH (at 30°C – 40°C)
≤ 45% RH (at 40°C – 50°C)
Operating Altitude 3000 meters
Storage Altitude 12,000 meters
EMC EN 61326-1:2006
Temperature Coefficients Add 0.1 x specified accuracy for each
degree C above 28°C or below 18°C
Safety Specifications
Safety Compliance CAN/CSA-C22.2 No. 61010-1-04
ANSI/UL 61010-1:2004
ANSI/ISA-61010-1 (82.02.01):2004
EN/IEC 61010-1:2001 to
1000V Measurement Category (CAT) III
600V Measurement Category (CAT) IV
Pollution Degree 2
EN/IEC 61010-2-032:2002
EN/IEC 61010-031:2002+A1:2008
Agency Approvals
Batteries 2 AA, NEDA 15A, IEC LR6
Model NameDescription
Fluke 375

True-rms AC/DC Clamp Meter

Included accessories:

  • Coated instruction card
  • Safety information sheet
  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries

Clips
AC220AC220 SureGrip™ Alligator Clips
AC87AC87 Heavy Duty Bus Bar Clip Set
AC89AC89 Heavy Duty Insulation Piercing Test Clip

Test Probes
TP1TP1 Slim Reach Test Probe Set

Cases and Holsters
C550C550 Tool Bag
CAMO-37Camouflage Carrying Case

Lights
L206L206 Deluxe LED Hat Light
LVD1LVD1 Volt Light

Test Leads
TL75TL75 Hard Point™ Test Lead Set
        
Related Products
 
 C781 Meter Case »
 
 i2500-10 iFlex® Flexible Current Probes »
 
 Fluke TL175 TwistGuard™ Test Leads »
Home   |   Site Map   |   Fluke Corporation   |   Safety Notices
Privacy Statement   |   Terms of Use  |   Terms and Conditions of Sale
© 1995 - 2015 Fluke Corporation