The most trusted tools in the world
Home  |  Products  |  Wireless Testers  |  Digital Multimeters  |  

Fluke CNX 3000 Wireless Multimeter

Displays the meter measurement, plus readings from up to 3 wireless modules, from up to 20 meters away.
Contact Me
Fluke CNX 3000 Wireless Multimeter
Fluke CNX 3000 Wireless Multimeter
Fluke CNX 3000 Wireless Multimeter with tilt stand.
Fluke CNX 3000 Wireless Multimeter, test leads.
Fluke CNX 3000 Wireless Multimeter displays multiple readings.

The CNX 3000 Wireless Multimeter is the captain of the Fluke wireless team.

With the CNX 3000 Wireless Multimeter, you see live measurements from multiple modules simultaneously and remotely on a single screen. The CNX 3000 Wireless Multimeter displays the meter measurement, plus readings from up to 3 wireless modules, as far as 20 meters away. By seeing multiple readings at the same time, troubleshooters can see cause and effect, interactions between inputs/outputs or other measurement points, simultaneously and remotely.

If more than three readings are required from more modules, add an optional PC adapter to your laptop for real time viewing of up to 10 modules.

View other members of the wireless team »

The CNX 3000 Wireless Multimeter has all the essentials for convenient test and measurement troubleshooting.
  • AC and DC voltage measurements to 1000V
  • AC and DC current with 0.01 mA resolution
  • Continuity, resistance, diode test, capacitance and frequency measurements
  • MIN/MAX Recording
  • CAT III 1000 V, Cat IV 600 V; IP54

Plus, the CNX wireless enabled modules measure AC voltage, AC current and temperature, which display on the CNX Wireless Multimeter. Choose a standard clamp or flexible clamp to measure AC current. Mix and match modules to suit your unique measurement needs. Read the primary measurement on the main display, and up to three modules at any one time. Modules are available separately or as part of CNX kits.

See multiple live measurements remotely on a single screen.
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range ¹ Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
))) 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
µF 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF ¹ 1 μF 10 %
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.

AC and DC Current
Function Range ¹ Resolution Accuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA
¹ All AC current ranges are specified from 5 % of range to 100 % of range.
² Input burden voltage (typical): 400 mA input 2 mV/mA.
³ 400.0 mA accuracy specified up to 600 mA overload.

Frequency
Range ¹ Resolution Accuracy
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

Input Characteristics
Function Overload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz  
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz
Open circuit test voltage Full scale Typical short circuit current
To 6 MΩ 50 MΩ
1100 V RMS < 2.7 V DC < 0.7 V DC < 0.9 V DC < 350 mA
1100 V RMS < 2.7 V DC 2.000 V DC < 1.1 mA

Function Overload Protection Overload
mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum

MIN/MAX Recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration

General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54
Model NameDescriptionBuy it
CNX 3000Fluke CNX 3000 Wireless Multimeter
  • True-RMS Wireless Multimeter
  • TL175 Test Leads
  • AC175 Alligator Clips
  •  
    CNX v3000Fluke CNX v3000 AC Wireless Voltage Module
  • True-RMS AC Voltage Module
  • TL224 Test Leads
  • AC285 Alligator Clips
  • Magnetic Hanging Strap
  •  
    CNX i3000Fluke CNX i3000 iFlex AC Wireless Current Module
  • True-RMS Flexible Current Meter
  • iFlex i2500-10 Flexible Current Probe
  • TL175 Test Leads
  • AC175 Alligator Clips
  • Magnetic Hanging Strap
  •  
    CNX a3000Fluke CNX a3000 AC Wireless Current Clamp Module
  • True-RMS AC Clamp Meter
  •  
    CNX t3000Fluke CNX t3000 K-Type Wireless Temperature Module
  • K-Type Thermocouple Thermometer
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  •  
    CNX i3000 KitFluke CNX i3000 iFlex AC Current Measurement Kit
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX i3000 iFlex AC Wireless Current Module
  • iFlex i2500-10 Flexible Current Probe
  • TL175 Test Leads
  • AC175 Alligator Clips
  • Magnetic Hanging Strap
  • Soft Carrying Case
  •  
    CNX v3000 Kit

    Fluke CNX v3000 AC Voltage Kit

  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX v3000 AC Wireless Voltage Module
  • TL224 Test Leads
  • TL175 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • Magnetic Hanging Strap
  • Soft Carrying Case
  •  
    CNX a3000 KitFluke CNX a3000 AC Current Clamp Kit
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX a3000 AC Wireless Current Clamp Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • Soft Carrying Case
  •  
    CNX t3000 KitFluke CNX t3000 Temperature Measurement Kit
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX t3000 K-Type Wireless Temperature Module
  • TL175 Test Leads
  • AC175 Alligator Clips
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  • Soft Carrying Case
  •  
    CNX 3000 GMFluke CNX 3000 General Maintenance System
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX v3000 AC Wireless Voltage Module
  • Fluke CNX i3000 iFlex AC Wireless Current Module
  • iFlex i2500-10 Flexible Current Probe
  • Fluke CNX pc3000 Wireless PC Adapter and Software
  • TL224 Test Leads
  • TL175 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • Two (2) Magnetic Hanging Straps
  • Soft Carrying Case
  •  
    CNX 3000 INDFluke CNX 3000 Industrial System
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX v3000 AC Wireless Voltage Module
  • Three (3) Fluke CNX i3000 iFlex AC Wireless Current Modules
  • Three (3) iFlex i2500-10 Flexible Current Probes
  • Fluke CNX pc3000 Wireless PC Adapter and Software
  • TL224 Test Leads
  • TL175 Test Leads
  • AC175 Alligator Clips
  • AC285 Alligator Clips
  • Four (4) Magnetic Hanging Straps
  •  
    CNX 3000 HVACFluke CNX 3000 HVAC System
  • Fluke CNX 3000 Wireless Multimeter
  • Fluke CNX a3000 AC Wireless Current Clamp Module
  • Fluke CNX t3000 K-Type Wireless Temperature Module
  • Fluke CNX pc3000 Wireless PC Adapter and Software
  • TL175 Test Leads
  • AC175 Alligator Clips
  • 80PK-1 K-Type Bead Thermocouple
  • Magnetic Hanging Strap
  • Soft Carrying Case
  •  

    Cases and HolstersBuy it
    CNX C3000CNX C3000 Premium Modular Tool Bag
    Webbed bag for customizable carrying system, when used with other CNX modular cases.
      
    CNX C3001CNX Small Modular Case C3001
    Compatible with wireless modules Fluke CNX
      
    CNX C3002CNX C3002 Modular DMM 2-Compartment Soft Case
  • Compatible with Fluke CNX Wireless Multimeter
  • Inner pocket and carrying handle
  •   
    CNX C3003CNX C3003 Modular 3-Compartment Soft Case
  • Compatible with Fluke CNX wireless modules and meters
  • Three adjustable compartments, inner pocket, and carrying handle
  •   

    PC Adapter and SoftwareBuy it
    CNX pc3000Fluke CNX pc3000 PC Adapter
    Fluke CNX sw3000 software
      

    TemperatureBuy it
    80PK-180PK-1 Bead Probe

    Test LeadsBuy it
    TL175TL175 TwistGuard™ Test Leads
            
    Related Products

     Write the first review
     
     CNX C3000 Premium Modular Tool Bag »

    3 reviews
     
     Fluke CNX 3000 Industrial System »

    1 review
     
     Fluke CNX i3000 iFlex AC Wireless Current Module »
    Home   |   Site Map   |   Fluke Corporation   |   Safety Notices  |   Terms and Conditions   |   Privacy Statement   |   Disclaimer © 1995 - 2013 Fluke Corporation